SC16C554 Philips Semiconductors, SC16C554 Datasheet - Page 30

no-image

SC16C554

Manufacturer Part Number
SC16C554
Description
Quad UART with 16-byte FIFO and infrared (IrDA) encoder/decoder
Manufacturer
Philips Semiconductors
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C554B
Manufacturer:
PHILIPS
Quantity:
129
Part Number:
SC16C554BIB64
Manufacturer:
NXP
Quantity:
301
Part Number:
SC16C554BIB64
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C554BIB64,151
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C554BIB64,157
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C554BIB80
Manufacturer:
NXP
Quantity:
1 000
Part Number:
SC16C554BIB80
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C554BIB80,528
Manufacturer:
Maxim
Quantity:
278
Part Number:
SC16C554BIB80,528
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C554BIBM
Manufacturer:
NXP
Quantity:
673
Part Number:
SC16C554BIBM,151
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Part Number:
SC16C554DB
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C554DBIA68
Manufacturer:
NXP
Quantity:
3 332
Part Number:
SC16C554DBIA68
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
SC16C554DBIA68,529
Manufacturer:
NXP Semiconductors
Quantity:
10 000
Philips Semiconductors
9397 750 13132
Product data
7.6 Modem Control Register (MCR)
This register controls the interface with the modem or a peripheral device.
Table 18:
Bit
7
6
5
4
3
2
1
0
Symbol
MCR[7]
MCR[6]
MCR[5]
MCR[4]
MCR[3]
MCR[2]
MCR[1]
MCR[0]
Modem Control Register bits description
Quad UART with 16-byte FIFO and infrared (IrDA) encoder/decoder
Rev. 05 — 10 May 2004
Description
Reserved; set to 0.
IR enable.
Reserved; set to 0.
Loop-back. Enable the local loop-back mode (diagnostics). In this
mode the transmitter output (TX) and the receiver input (RX), CTS,
DSR, CD, and RI are disconnected from the SC16C554/554D I/O
pins. Internally the modem data and control pins are connected into a
loop-back data configuration (see
and transmitter interrupts remain fully operational. The Modem
Control Interrupts are also operational, but the interrupts’ sources are
switched to the lower four bits of the Modem Control. Interrupts
continue to be controlled by the IER register.
OP2, INTx enable. Used to control the modem CD signal in the
loop-back mode.
OP1. This bit is used in the Loop-back mode only. In the loop-back
mode, this bit is used to write the state of the modem RI interface
signal via OP1.
RTS
Automatic RTS may be used for hardware flow control by enabling
EFR[6]. See
DTR
Logic 0 = Enable the standard modem receive and transmit
input/output interface (normal default condition).
Logic 1 = Enable infrared IrDA receive and transmit inputs/outputs.
While in this mode, the TX/RX output/inputs are routed to the
infrared encoder/decoder. The data input and output levels will
conform to the IrDA infrared interface requirement. As such, while
in this mode, the infrared TX output will be a logic 0 during idle data
conditions.
Logic 0 = Disable loop-back mode (normal default condition).
Logic 1 = Enable local loop-back mode (diagnostics).
Logic 0 = Forces INTA-INTD outputs to the 3-State mode during
the 16 mode (normal default condition). In the loop-back mode,
sets OP2 (CD) internally to a logic 1.
Logic 1 = Forces the INTA-INTD outputs to the active mode during
the 16 mode. In the loop-back mode, sets OP2 (CD) internally to a
logic 0.
Logic 0 = Force RTS output to a logic 1 (normal default condition).
Logic 1 = Force RTS output to a logic 0.
Logic 0 = Force DTR output to a logic 1 (normal default condition).
Logic 1 = Force DTR output to a logic 0.
Table
21.
SC16C554/554D
Figure
© Koninklijke Philips Electronics N.V. 2004. All rights reserved.