LT1910 Linear Technology, LT1910 Datasheet - Page 2

no-image

LT1910

Manufacturer Part Number
LT1910
Description
Protected High Side MOSFET Driver
Manufacturer
Linear Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LT1910CS8
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT1910ECS8
Manufacturer:
FUJI
Quantity:
58
Part Number:
LT1910ES8
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT1910ES8#PBF
Manufacturer:
LT
Quantity:
43
Part Number:
LT1910ES8#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT1910ES8#TRPBF
Manufacturer:
JVC
Quantity:
67
Part Number:
LT1910ES8#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT1910ES8#TRPBF
0
Part Number:
LT1910IS8
Manufacturer:
LT
Quantity:
10 000
Part Number:
LT1910IS8
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LT1910IS8#PBF
Manufacturer:
LT
Quantity:
1 600
ABSOLUTE
ELECTRICAL CHARACTERISTICS
LT1910
(Note 1)
Supply Voltage (Pin 8) ............................... –15V to 60V
Input Voltage (Pin 4) .................... (GND – 0.3V) to 15V
GATE Voltage (Pin 5) .............................................. 75V
SENSE Voltage (Pin 6) ....................................... V
FAULT Voltage (Pin 3) ............................................ 36V
Current (Pins 1, 2, 4, 5, 6, 8) ............................... 40mA
Operating Ambient Temperature Range
(Note 2) ...................................................–40 C to 85 C
Junction Temperature Range ................ –40 C to 125 C
Storage Temperature Range ................. – 65 C to 150 C
Lead Temperature (Soldering, 10 sec).................. 300 C
range, otherwise specifications are at T
SYMBOL
I
V
V
I
C
V
V
I
V
I
V
V
V
t
t
t
Note 1: Absolute Maximum Ratings are those values beyond which the life
of a device may be impaired.
Note 2: The LT1910E is guaranteed to meet performance specifications
from 0 C to 70 C. Specifications over the – 40 C to 85 C operating
temperature range are assured by design, characterization and correlation
with statistical process controls.
Note 3: Guaranteed but not tested.
2
S
IN
T
SENSE
ON
OFF
OFF(CL)
INH
INL
IN
T(TH)
T(CL)
SENSE
GATE
F(TH)
FOL
I
S(ON)
– V
+
PARAMETER
Supply Current (OFF State)
Delta Supply Current (ON State)
Input High Voltage
Input Low Voltage
Input Current
Input Capacitance (Note 3)
Timer Threshold Voltage
Timer Clamp Voltage
Timer Charge Current
Drain Sense Threshold Voltage
Temperature Coefficient (Note 3)
Drain Sense Input Current
Gate Voltage Above Supply
FAULT Output High Threshold Voltage
FAULT Output Low Threshold Voltage
FAULT Output Low Voltage
Turn-On Time
Turn-Off Time
Current Limit Turn-Off Time
W
MAXIMUM
W W
A
= 25 C. V
RATINGS
U
+
= 12V to 48V unless otherwise noted.
CONDITIONS
V
V
V
V
V
V
V
V
V
V
V
V
V
I
V
V
V
F
+
IN
IN
IN
IN
IN
IN
+
+
+
+
+
IN
+
+
+
= 1mA
= 48V, V
= 48V, V
= 8V
= 12V
= 24V
= 48V
= 24V, V
= 24V, V
= 24V, (V
= 2V, Measure Increase in I
= 2V
= 5V
= 2V, Adjust V
= 0.8V
= V
= 2V, I
+
The
T
= 2V
F
5V
IN
SENSE
GATE
GATE
= 1mA, Adjust V
+
= 0.8V
– V
denotes specifications that apply over the full operating temperature
= 32V, C
= 2V, C
SENSE
= 65mV
T
PACKAGE/ORDER
Consult LTC Marketing for parts specified with wider operating temperature ranges.
) 0.1V, C
GATE
GATE
TIMER
FAULT
GND
T
= 1nF
IN
T
= 1nF
JMAX
S
1
2
3
4
GATE
8-LEAD PLASTIC SO
= 125 C,
S8 PACKAGE
TOP VIEW
= 1nF
JA
= 150 C/W
8
7
6
5
V
NC
SENSE
GATE
+
MIN
100
1.2
2.6
3.2
3.1
3.0
15
55
50
10
10
2
9
4
7
INFORMATION
U
S8 PART MARKING
0.33
0.07
TYP
110
220
1.9
0.8
2.9
3.5
0.5
4.5
8.5
3.4
3.3
65
30
14
12
12
25
20
5
ORDER PART
LT1910ES8
W
NUMBER
1910E
MAX
185
400
100
2.5
1.2
0.8
3.2
3.8
1.5
3.7
3.6
0.4
50
20
80
10
14
14
50
6
sn1910 1910fs
UNITS
U
%/ C
mA
mA
mV
pF
V
V
A
A
V
V
A
A
V
V
V
V
V
V
V
s
s
s

Related parts for LT1910