TEA-2261 ST Microelectronics, TEA-2261 Datasheet - Page 5

no-image

TEA-2261

Manufacturer Part Number
TEA-2261
Description
SWITCH MODE POWER SUPPLY CONTROLLER
Manufacturer
ST Microelectronics
Datasheet
GENERAL DESCRIPTION
The TEA2260/61 is an off-line switch mode power
supply controller. The synchronization function and
the specific operation in stand-by mode make it well
adapted to video applications such as TV sets,
VCRs, monitors, etc...
The TEA2260/61 can be used in two types of
architectures :
- Master/slave architecture. In this case, the
- Conventional architecture with linear feedback
Using the TEA2260/61, the stand-by auxiliary
power supply, often realized with a small but costly
50Hz transformer, is no longer necessary. The
burst mode operation of the TEA2260/61 makes
possible the control of very low output power (down
to less than 1W) with the main power transformer.
When used in a master/slave architecture, the
TEA2260/61 and also the power transistor turn-off
can be easily synchronized with the line trans-
former. The switching noise cannot disturb the
picture in this case.
As an S.M.P.S. controller, the TEA2260/61 features
the following functions :
- Power supply start-up (with soft-start)
- PWM generator
- Direct power transistor drive (+1.2A, -2.0A)
- Safety functions : pulse by pulse current limita-
S.M.P.S. OPERATING DESCRIPTION
Starting Mode - Stand By Mode
Power for circuit supply is taken from the mains
through a high value resistor before starting. As
long as V
the quiescent current is very low (typically 0.7mA)
and the electrolytic capacitor across V
charged. When V
10.3V), the circuit starts, generating output pulses
with a soft-starting. Then the SMPS goes into the
stand-by mode and the output voltage is a percen-
tage of the nominal output voltage (eg. 80%).
For this the TEA2260/61 contains all the functions
required for primary mode regulation : a fixed fre-
quency oscillator, a voltage reference, an error
amplifier and a pulse width modulator (PWM).
For transmission of low power with a good effi-
ciency in stand-by, an automatic burst generation
TEA2260/61 drives the power transistor accord-
ing to the pulse width modulated signals gener-
ated by the secondary located master circuit. A
pulse transformer provides the feedback (see
Figure 1).
signal (feedback sources : optocoupler or trans-
former winding) (see Figure 2).
tion, output power limitation, over and under volt-
age lock-out.
CC
of the TEA2260/61 is below V
CC
reaches V
CC
start (typically
CC
is linearly
CC
start,
system is used, in order to avoid audible noise.
Normal Mode (secondary regulation)
The normal operating of the TV set is obtained by
sending to the TEA2260/61 regulation pulses gen-
erated by a regulator located in the secondary side
of the power supply.
This architecture uses the "Master-slave Concept",
advantages of which are now well-known espe-
cially the very high efficiency in stand-by mode, and
the accurate regulation in normal mode.
Stand-by mode or normal mode are obtained by
supplying or not the secondary regulator. This can
be ordonnered for exemple by a microprocessor in
relation with the remote control unit.
Regulation pulses are applied to the TEA2260/61
through a small pulse-transformer to the IN input
(Pin 2). This input is sensitive to positive square
pulses. The typical threshold of this input is 0.85V.
The frequency of pulses coming from the secon-
dary regulator can be lower or higher than the
frequency of the starting oscillator.
The TEA2260/61 has no soft-starting system when
it receives pulses from the secondary. The soft-
starting has to be located in the secondary regula-
tor.
Due to the principle of the primary regulation,
pulses generated by the starting system automat-
ically disappear when the voltage delivered by the
SMPS increases.
Stand-by Mode - Normal Mode Transition
During the transition there are simultaneously
pulses coming from the primary and secondary
regulators.
These signals are not synchronized and some care
has to be taken to ensure the safety of the switching
power transistor.
A very sure and simple way consist in checking the
transformer demagnetization state.
- A primary pulse is taken in account only if the
- A secondary pulse is taken in account only if the
With this arrangement the switching safety area of
the power transistor is respected and there is no
risk of transformer magnetization.
The magnetization state of the transformer is
checked by sensing the voltage across a winding
of the transformer (generally the same which sup-
plies the TEA2261). This is made by connecting a
resistor between this winding and the demagneti-
zation sensing input of the circuit (Pin 1).
transformer is demagnetized after a conduction
of the power transistor required by the secondary
regulator.
transformer is demagnetized after a conduction
of the power transistor required by the primary
regulator.
TEA2260 - TEA2261