NT3-24AC-F100-D60 Willow Technologies Ltd, NT3-24AC-F100-D60 Datasheet

no-image

NT3-24AC-F100-D60

Manufacturer Part Number
NT3-24AC-F100-D60
Description
Ac Linear Solenoids
Manufacturer
Willow Technologies Ltd
Datasheet
AC Linear Solenoids
Open frame linear solenoids ideally suited
for AC applications, having the frame and
the
construction, featuring high permeability
and low magnetic losses. They are
designed to be operated in any position,
being able turning an electric pulse into an
axial pull action. Coil winding insulation
being in Class F. Performance, as shown
in the following diagrams, is always
referred to a temperature rise of 80°C in
open air, with 35°C ambient temperature
and coil fed at 105% of rated supply
voltage (as per VDE 0580). Since the
mechanical
ON and OFF times corresponding to
relative duty factors lower than ED=100
result, for standard ED values, from the
following diagram:
Current values given in our diagrams are
at nominal voltage. Forces shown are
referred to solenoids fed @ 90% of rated
voltage, with ‘hot’ coil and 20°C ambient
temperature.
Any AC solenoid, due to its high power
consumption (VA), will rapidly overheat
and fail to operate, whenever its plunger is
prevented from seating properly. To avoid
this, a proper spring can be interposed
between plunger and application. When
adopting a solenoid please also bear in
mind what follows:
1) Any load should be always applied
strictly along the plunger main axis (to
avoid excessive wear due to friction, and
noise
generated by the AC power supply).
2) Any mechanical stroke-limiting device
eventually provided, should be made of
non magnetic material.
ORDERING IMFORMATION
NT3-24AC-F100-D60
1
plunger
2
magnifying
3
ITALIANA
RELE
energy
of
4
due
laminated
generated
5
Tel (+39) 02 6140851- Fax (+39) 02 6140339 - E-mail: rele@rele.it - www.rele.it
I T A L I A N A R E L E' S r l. - Via dei Bravi, 40
to
6
vibration
7
steel
by
SERIES NT
solenoids is a constant, any amount of
that force eventually not utilised by
relevant application will be expended
under form of impact force. Consequently,
any application should correctly use the
smallest available solenoid performing the
required
maximum
temperature. To select the right solenoid,
an exact determination of the duty cycle is
equally essential: whenever the maximum
cycle is exceeding 300 seconds, a
continuously rated solenoid (ED=100)
should be used. Otherwise the relative
duty factor would result as follows:
3) The expected life of a solenoid would
be remarkably increased as much as its
impact force could be absorbed by the
solenoid mounting frame.
When a continuously rated (ED=100)
solenoid is required but space is not
enough, a resistor and/or a limiting
impedance could be used to feed a
smaller
(ED<100). Models NT1 and NT2 are
supplied with built-in fixing brackets, while
models NT3 and NT4 have no bracket,
even if these are available as a separate
optional kit (for mounting on left, right or
lower side position, as required).
Prior to select the right solenoid you must
1 - Solenoid series: NT
2 - Type (size) :1-2-3-4
3 - Coil supply voltage (AC only).
4 - Coil terminals:
5 - Relative duty service ED%:
F = Faston 0.25 (6.3x0,8mm)
C = 150mm leads
Permanently (100) or intermittently
rated coils (standard values: 40-25-
15-5)
Operation
per hour
1200
1800
3000
120
300
600
12
intermittently
action,
admitted
Total cycle
(seconds)
not
300
1.2
30
12
6
3
2
rated
exceeding
RELATIVE DUTY FACTOR (ED%)
operational
0.48 0.72
ON
120
4.8
2.4
1.2
0.8
12
solenoid
I-20032 CORMANO - Italy
ED 40
OFF
180
18
7.2
3.6
1.8
1.2
the
ED% =
(Cycle = ON + OFF time)
always know the force required, as well as
stroke, maximum feeding time, minimum
OFF time, ambient temperature and
supply voltage. If in doubt to select the
best type for your application, please do
not hesitate contacting us to help you
making the right choice, supplying us with
all above required information. Even if you
can’t find the solenoid you require in our
range, please let us know, as we do have
both the experience and the know-how to
solve any problem in this field.
6 - Fixing brackets (NT1-NT2 only):
7 - Coil supply frequency
NB: When ordering standard types
you can omit the last two groups
of code (6 and 7).
0.75
ON
7.5
75
3.0
1.5
0.5
0.3
ED 25
D = on right side (standard)
S = on left side (on request)
(if different from 50 Hz).
225
22.5
OFF
9.0
4.5
2.25
1.5
0.9
(On + OFF time)
ON time
0.45
0.18
ON
4.5
1.8
45
0.9
0.3
ED 15
255
25.5
10.2
OFF
5.1
2.55
1.7
1.02
.
x 100
ON
0.15
0.06
1.5
0.6
15
0.3
0.1
ED 5
285
28.5
11.4
OFF
5.7
2.85
1.9
1.14

Related parts for NT3-24AC-F100-D60

NT3-24AC-F100-D60 Summary of contents

Page 1

... AC power supply). 2) Any mechanical stroke-limiting device eventually provided, should be made of non magnetic material. ORDERING IMFORMATION NT3-24AC-F100-D60 Via dei Bravi, 40 Tel (+39) 02 6140851- Fax (+39) 02 6140339 - E-mail: rele@rele.it - www.rele.it ...

Page 2

... Axial Force (Kg) Vs. Stroke and Duty Service (ED) Stroke (mm 100 1.70 1.40 1.05 0. 2.70 2.20 1.60 1. 3.10 2.50 1.80 1. 3.60 2.90 2.05 1. 4.30 3.40 2.40 1.70 - NT3 Coil supply voltages : Insulating resistance : Dielectric strength : Coil terminals : Total weight : Plunger weight : Axial Force (Kg) Vs. Stroke and Duty Service (ED) Stroke (mm 100 2.10 1.60 1.00 0.80 0.70 40 2.70 2.05 1.30 1.00 0.95 25 2.90 2.20 1.40 1.20 1.05 15 3.10 2.35 1.50 1.30 1 ...