BTS 7741G Infineon Technologies, BTS 7741G Datasheet - Page 6

no-image

BTS 7741G

Manufacturer Part Number
BTS 7741G
Description
Manufacturer
Infineon Technologies
Datasheet

Specifications of BTS 7741G

Packages
P-DSO-28
Operating Range
4.8 - 42.0 V
Rds (on) (typ)
210.0 mOhm
Id(lim)
10.0 A
Iq (typ)
5.0 µA
Diagnosis
OT, OL Status Flag
Data Sheet
Open Load Detection
Open load is detected by voltage measurement in Off state. If the output voltage exceeds
a specified level the error flag is set with a delay.
Status Flag
The status flag output is an open drain output with Zener-diode which requires a pull-up
resistor, c.f. the application circuit on page 14. Various errors as listed in the table
“Diagnosis” are detected by switching the open drain output ST to low. An open load
detection is available when there is an external resistor < R
DHVS or Vs. In order to reach low quiescent current, we recommend to disconnect this
resistor when not used.
2
Flag
Normal operation;
identical with functional truth table
Open load at high-side switch 1
Open load at high-side switch 2
Overtemperature high-side switch1
Overtemperature high-side switch2
Overtemperature both high-side switches
Under voltage
Inputs:
0 = Logic LOW
1 = Logic HIGH
X = don’t care
Truth table and Diagnosis (valid only for the High-Side-Switches)
Outputs:
Z = Output in tristate condition
L = Output in sink condition
H = Output in source condition
X = Voltage level undefined
IH1
0
0
1
1
0
1
X
X
0
1
X
X
0
X
1
X
6
Inputs
X
IH2
0
1
0
1
X
X
0
1
X
X
0
1
0
1
X
SH1
L
L
H
H
Z
H
X
X
L
L
X
X
L
L
L
L
Outputs
Status:
1 = No error
0 = Error
0
SH2
L
H
L
H
X
X
Z
H
X
X
L
L
L
L
L
L
from SH1 and SH2 pin to
1
ST Remarks
1
1
1
1
0
1
0
1
1
0
1
0
1
0
0
BTS 7741 G
stand-by mode
switch2 active
switch1 active
both switches
active
detected
detected
detected
detected
detected
detected
not detected
2003-03-06