SEMiX501D17Fs SEMIKRON, SEMiX501D17Fs Datasheet

no-image

SEMiX501D17Fs

Manufacturer Part Number
SEMiX501D17Fs
Description
Manufacturer
SEMIKRON
Datasheet

Specifications of SEMiX501D17Fs

Family/system
SEMiX
Voltage (v)
1700
Current (a)
489
Case
SEMiX 13
Switches
6

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SEMIX501D17FS
Manufacturer:
SEMIKRON
Quantity:
20 000
SEMiX501D17Fs
Bridge Rectifier Module
(uncontrolled)
SEMiX501D17Fs
Features
• Terminal height 17 mm
• Chips soldered directly to isolated
Typical Applications*
• Fast Input Bridge Rectifier for AC/DC
• Power supply
• High frequency applications
© by SEMIKRON
SEMiX
substrate
motor control
®
13
D
Absolute Maximum Ratings
Symbol
Rect. Diode
I
I
i
V
V
T
Module
T
V
Characteristics
Symbol
Rectifier Diode
V
V
r
I
R
Module
R
M
M
a
w
F
FSM
2
RD
T
t
RSM
RRM
j
stg
isol
F
(TO)
th(j-c)
th(c-s)
s
t
Rev. 0 – 13.10.2011
T
10 ms
AC sinus 50Hz
T
T
T
Conditions
Conditions
T
per chip
per module
to heat sink (M5)
to terminals (M6)
j
j
j
j
j
= 150 °C
= 25 °C, chip
= 125 °C, chip
= 125 °C, chip
= 125 °C, V
RD
= V
T
T
T
T
T
T
1 min
1 s
per diode
RRM
c
c
j
j
j
j
= 25 °C
= 150 °C
= 25 °C
= 150 °C
= 85 °C
= 100 °C
min.
2.5
3
-40 ... 150
-40 ... 125
Values
37538
22898
2740
2140
1700
1700
4000
4800
typ.
0.04
489
412
350
5 * 9,81
max.
0.165
1.9
1.1
2.7
4
5
5
Unit
Unit
m/s²
K/W
K/W
K/W
K/W
A²s
A²s
m
Nm
Nm
mA
°C
°C
A
A
A
A
V
V
V
V
V
V
g
1

Related parts for SEMiX501D17Fs

SEMiX501D17Fs Summary of contents

Page 1

... SEMiX501D17Fs SEMiX ® 13 Bridge Rectifier Module (uncontrolled) SEMiX501D17Fs Features • Terminal height 17 mm • Chips soldered directly to isolated substrate Typical Applications* • Fast Input Bridge Rectifier for AC/DC motor control • Power supply • High frequency applications D © by SEMIKRON Absolute Maximum Ratings ...

Page 2

... SEMiX501D17Fs SEMiX 13 This is an electrostatic discharge sensitive device (ESDS), international standard IEC 60747-1, Chapter IX * The specifications of our components may not be considered as an assurance of component characteristics. Components have to be tested for the respective application. Adjustments may be necessary. The use of SEMIKRON products in life support appliances and systems is subject to prior specification and written approval by SEMIKRON ...

Related keywords