CS6422-CS Cirrus Logic Inc, CS6422-CS Datasheet - Page 27

no-image

CS6422-CS

Manufacturer Part Number
CS6422-CS
Description
IC CODEC SPKRPHONE 2CH 20-SOIC
Manufacturer
Cirrus Logic Inc
Type
Audio Processorr
Datasheet

Specifications of CS6422-CS

Mounting Type
Surface Mount
Package / Case
20-SOIC
Applications
Speakerphones
Peak Reflow Compatible (260 C)
No
Termination Type
SMD
Supply Voltage Max
5.5V
Leaded Process Compatible
No
Supply Voltage Min
4.5V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
598-1199-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS6422-CS
Manufacturer:
TI
Quantity:
101
Part Number:
CS6422-CS
Quantity:
200
Part Number:
CS6422-CS
Manufacturer:
CS
Quantity:
20 000
Part Number:
CS6422-CSZ
Manufacturer:
CIRRUS
Quantity:
61
Part Number:
CS6422-CSZ
Manufacturer:
CIRRUS
Quantity:
4
Part Number:
CS6422-CSZ
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS6422-CSZR
Manufacturer:
CREE
Quantity:
210
Part Number:
CS6422-CSZR
Manufacturer:
CIRRUS
Quantity:
1 015
3.8.1
3.8.2
3.8.3
3.8.4
3.8.5
DS295F1
HWLD - HOWL DETECTOR DISABLE
TD - TONE DETECTOR DISABLE
APCD - ACOUSTIC PATH CHANGE DETECTOR DISABLE
NPCD - NETWORK PATH CHANGE DETECTOR DISABLE
APFD/NPFD - ACOUSTIC PRE-EMPHASIS FILTER DISABLE/NETWORK PRE-EMPHASIS
FILTER DISABLE
This is a diagnostic parameter that is normally set to ‘0’.
In normal operation, the CS6422 will clear both the AEC and NEC coefficients, dropping the device
into half-duplex operation, whenever an instability event is detected. Such an event can be caused
by excessive loop gain, a major path change, or mistraining of the echo cancellers.
Setting HwlD to ‘1’ prevents the instability detector from clearing the echo cancellers’ coefficients.
This is a diagnostic parameter that is normally set to ‘0’.
In normal operation, the tone detector responds to the detection of tones in the receive path. If the
CS6422 is in half-duplex mode, the tone detector will clear the AEC coefficients and force the half-
duplex engine into <Receive> mode to allow the tone to pass through, independent of the presence
of signals at the near-end microphone.
If the CS6422 is in full-dulpex mode when a tone is detected, the tone detector will momentarily freeze
the AEC coefficients to prevent false training.
This diagnostic bit is normally set to ‘0’.
The purpose of the acoustic path change detector is to respond to drastic path changes by clearing
the AEC coefficients to facilitate rapid and accurate convergence to the new path.
Disabling the acoustic path change detector prevents it from clearing the AEC coefficients, thus forc-
ing the filter to ‘adapt out’ of the path change, which typically takes longer and is less accurate than
adapting from a cleared state.
This diagnostic bit is normally set to ‘0’.
The purpose of the network path change detector is to respond to drastic path changes by clearing
the NEC coefficients to facilitate rapid and accurate convergence to the new path.
Disabling the network path change detector prevents it from clearing the NEC coefficients, thus forc-
ing the filter to ‘adapt out’ of the path change, which typically takes longer and is less accurate than
adapting from a cleared state.
These diagnostic bits are normally set to ‘0’.
The pre-emphasis filter helps the adaptive filter correctly model the coupling path by attenuating lower
frequency information. This is done because high-frequency information more accurately describes
the echo path, that is, low frequency information is more spatially ambiguous.
Sometimes it is useful to disable the pre-emphasis filter when performing ERLE tests using white
noise, since the filter will tend to prevent the adaptive filter from cancelling the low frequency compo-
nents of the signal, resulting in artificially low ERLE measurements.
CS6422
CS6422
27
27