AD7294 Analog Devices, AD7294 Datasheet - Page 40

no-image

AD7294

Manufacturer Part Number
AD7294
Description
12-Bit Monitor and Control System with Multichannel ADC, DACs, Temperature Sensor, and Current Sense
Manufacturer
Analog Devices
Datasheet

Specifications of AD7294

Resolution (bits)
12bit
# Chan
9
Sample Rate
200kSPS
Interface
I²C/Ser 2-Wire,Ser
Analog Input Type
Diff-Uni,SE-Uni
Ain Range
(Vref) p-p,2 V p-p,Uni (Vref),Uni (Vref) x 2
Adc Architecture
SAR
Pkg Type
CSP

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7294-2BSUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7294BCPZ
Manufacturer:
VK
Quantity:
3 218
Part Number:
AD7294BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7294BSUZ
Manufacturer:
ADI
Quantity:
200
Part Number:
AD7294BSUZ
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD7294BSUZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD7294BSUZRL
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD7294BSUZRL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
AD7294
AUTOCYCLE MODE
The
programmable sequence of channels making it the ideal mode
of operation for system monitoring. These conversions take
place in the background approximately every 50 µs, and are
transparent to the master. Typically, this mode is used to
automatically monitor a selection of channels with either the
limit registers programmed to signal an out-of-range condition
via the alert function or the minimum/maximum recorders
tracking the variation over time of a particular channel. Reads
and writes can be performed at any time (the ADC Result
Register 0x01 contains the most recent conversion result).
On power up, this mode is disabled. To enable this mode, write
to Bit D12 in the configuration register (0x09) and select the
desired channels for conversion in the channel sequence
register (0x08).
If a command mode conversion is required while the autocycle
mode is active, it is necessary to disable the autocycle mode before
AD7294
can be configured to convert continuously on a
Rev. H | Page 40 of 48
proceeding to the command mode. This is achieved either by clear-
ing Bit D12 of the configuration register or by writing 0x00 to the
channel sequence register. When the command mode conversion is
complete, the user must exit command mode by issuing a stop
condition before reenabling autocycle mode.
When switching out of autocycle mode to command mode,
the temperature sensor must be given sufficient time to settle
and complete a new temperature integration cycle. Therefore,
temperature sensor conversions performed within the first
500 ms after switching from autocycle mode to command mode
may result in false temperature high and low alarms being
triggered. It is recommended to disable temperature sensor
alarms for the first 500 ms after mode switching by writing
0x400 to the DATA
DATA
be reconfigured to the desired alarm level once the 500 ms has
elapsed. Alternatively, temperature alerts triggered during the
first 500 ms after mode switching should be ignored.