PS21965-A MITSUBISHI, PS21965-A Datasheet - Page 4

no-image

PS21965-A

Manufacturer Part Number
PS21965-A
Description
Manufacturer
MITSUBISHI
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PS21965-A
Manufacturer:
MITSUBISHI
Quantity:
334
Part Number:
PS21965-AST
Quantity:
492
Part Number:
PS21965-AT
Manufacturer:
SEMIKRON
Quantity:
134
Part Number:
PS21965-AT#500
Manufacturer:
MITSUBISH
Quantity:
1 000
MAXIMUM RATINGS
INVERTER PART
Note 1 : The maximum junction temperature rating of the power chips integrated within the DIP-IPM is 150°C (@ T
CONTROL (PROTECTION) PART
V
V
V
±I
±I
P
T
V
V
V
V
I
V
FO
Symbol
Symbol
Fig. 6 EXTERNAL PART OF THE DIP-IPM PROTECTION CIRCUIT
CC
CC(surge)
CES
C
j
D
DB
IN
FO
SC
C
CP
N1
Note1: In the recommended external protection circuit, please select the RC time constant in the range 1.5~2.0µs.
External protection circuit
2: To prevent erroneous protection operation, the wiring of A, B, C should be as short as possible.
ensure safe operation of the DIP-IPM, the average junction temperature should be limited to T
Shunt Resistor
(Note 1)
Supply voltage
Supply voltage (surge)
Collector-emitter voltage
Each IGBT collector current
Each IGBT collector current (peak)
Collector dissipation
Junction temperature
Control supply voltage
Control supply voltage
Input voltage
Fault output supply voltage
Fault output current
Current sensing input voltage
C R
C
A
B
(Note 2)
(T
V
CIN
N
NC
P
j
DIP-IPM
= 25°C, unless otherwise noted)
H-side IGBT
L-side IGBT
Parameter
Parameter
Protection circuit
S
S
Drive circuit
Drive circuit
Applied between P-N
Applied between P-N
T
T
T
Applied between V
Applied between V
Applied between U
Applied between F
Sink current at F
Applied between CIN-V
C
C
C
= 25°C
= 25°C, less than 1ms
= 25°C, per 1 chip
W
U
V
Short Circuit Protective Function (SC) :
SC protection is achieved by sensing the L-side DC-Bus current (through the external
shunt resistor) after allowing a suitable filtering time (defined by the RC circuit).
When the sensed shunt voltage exceeds the SC trip-level, all the L-side IGBTs are turned
OFF and a fault signal (Fo) is output. Since the SC fault may be repetitive, it is
recommended to stop the system when the Fo signal is received and check the fault.
4
I
C
(A)
O
Condition
Condition
W
0
P
O
terminal
P1
UFB
N
, V
-V
-V
-V
-U, V
P
NC
NC
Collector current
NC
NC
, W
2
waveform
, V
P
VFB
, U
N1
N
-V
-V, V
SC Protection
, V
PS21965-T/-AT/-CT/-TW
Trip Level
NC
t
(Note 1)
N
w
WFB
,
(µs)
-W
j(ave)
≤ 125°C (@ T
TRANSFER-MOLD TYPE
–0.5~V
–0.5~V
–0.5~V
–20~+125
Ratings
Ratings
35.7
450
500
600
20
40
20
20
C
INSULATED TYPE
1
D
D
D
≤ 100°C). However, to
+0.5
+0.5
+0.5
C
≤ 100°C).
Aug. 2007
Unit
Unit
mA
°C
W
V
V
V
A
A
V
V
V
V
V

Related parts for PS21965-A