Conducted EMS
Electro Magnetic Susceptibility is measured by injection of electri-
cal disturbances on the input terminals. No deviation outside the
V
Frequency range
0.15...300 MHz
Radiated EMS (Electro-Magnetic Fields)
Radiated EMS is measured according to test methods in
IEC Standard publ. 801-3. No deviation outside the V
band will occur under the following conditions:
Frequency range
0.01...200 MHz
200...1,000 MHz
1...12 GHz
ESD
Electro Static Discharge is tested according to IEC publ. 801-2.
No destruction will occur if the following voltage levels are ap-
plied to any of the terminal pins:
Test
Air discharge
Contact discharge
EFT
output voltage regulation causing functional errors on the Printed
Board Assembly (PBA). The PKF power modules withstand EFT
levels of 0.5 kV keeping V
2.0 kV without destruction. Tested according to IEC publ. 801-4.
Output Ripple & Noise (V
Output ripple is measured as the peak to peak voltage of the
fundamental switching frequency.
6
PKF 4910A with filter
The signal is amplitude modulated with 1 kHz/80% and applied
in both differential and common mode.
Electrical Fast Transients on the input terminals could affect the
O
tolerance band will occur under the following conditions:
Voltage level
1.0 V
Voltage level
3 V
3 V
10 V
Voltage level
±4 kV
±2 kV
O
rms
rms
rms
within the tolerance band and
rms
/m
/m
/m
O
ac)
O
tolerance
Operating Information
Fuse Considerations
To prevent excessive current from flowing through the input
supply line, in the case of a short-circuit across the converter
input, an external fuse should be installed in the non-earthed
input supply line. We recommend using a fuse rated at
approximately 2 to 4 times the value calculated in the formula
below:
I
Refer to the fuse manufacturer for further information.
Remote Control (RC)
Turn-on or turn-off can be realized by using the RC-pin. If pin 11
is connected to pin 17 the power modules turns off. Normal
operation is achieved if pin 11 is open (NC). To ensure safe turn-
off the voltage difference between pin 11 and 17 shall be less than
1.0 V. RC is an open collector compatible input. A sink capacity
of 1mA is needed. (see fig. 1).
Turn-on/off Input Voltage
The power module monitors the input voltage and will turn on
and turn off at predetermined levels set by means of external
resistors.
To increase V
and 17 (see fig.2).
The resistance is given by the following equation
(For V
R
V
V
To decrease V
and 11 (see fig. 3). The resistance is given by the following equa-
tion (for 32V < V
R
in max
Ioff
Ion
Ion
Ion
–V
= (2780 – V
is the adjusted turn-off input voltage and is determined by
= 49 × (V
=
Ion
Ioff
>36V):
(h
= 2 V (typical value).
min
P
EN/LZT 146 86 R1A © Ericsson Microelectronics AB, December 2001
Ion
O max
Ion
Ion
× V
Ion
Ion
a resistor should be connected between pin 11
– 32.0) /(36.0 – V
a resistor should be connected between pin 10
I min
)/(V
> 36 V):
)
Ion
– 36.0) kW
Ion
) kW