dc-dc Converters; 36 to 75 Vdc Input, 12 Vdc Output; 50 W to 150 W
Test Configurations
Note: Measure input reflected-ripple current with a simulated source
Note: Use a 1.0 µF ceramic capacitor and a 10 µF aluminum or tan-
Figure 18. Peak-to-Peak Output Noise
Note: All measurements are taken at the module terminals. When
Figure 19. Output Voltage and Efficiency
10
10
BATTERY
η
=
V
Figure 17. Input Reflected-Ripple Test Setup
V
SUPPLY
inductance (L
tery impedance. Measure current as shown above.
O
talum capacitor. Scope measurement should be made using a
BNC socket. Position the load between 51 mm and 76 mm
(2 in. and 3 in.) from the module.
socketing, place Kelvin connections at module terminals to
avoid measurement errors due to socket contact resistance.
O
RESISTANCE
(+)
(–)
[
------------------------------------------------------ -
CONTACT
TO OSCILLOSCOPE
V
[
V
O
I
+ ( ) – V
+ ( ) – V
Measurement Test Setup
Measurement Test Setup
I
I
TEST
C
ESR < 0.1 Ω
@ 20 ˚C, 100 kHz
COPPER STRIP
(
1.0 µF
(
S
220 µF
O
) of 12 µH. Capacitor C
I
– ( )
V
V
– ( )
12 µH
I
I
(+)
(
L
)
)
)
TEST
]I
]I
I
SENSE(+)
SENSE(
O
10 µF
⎞ x 100
V
V
ESR < 0.7 Ω
O
@ 100 kHz
O
(
(+)
)
)
33 µF
SCOPE
CURRENT
PROBE
DISTRIBUTION LOSSES
S
I
%
O
offsets possible bat-
CONTACT AND
RESISTIVE
LOAD
V
V
I
I
(+)
(–)
LOAD
8-513 (C).b
8-203 (C).l
8-749 (C)
Design Considerations
Input Source Impedance
The power module should be connected to a low
ac-impedance input source. Highly inductive source
impedances can affect the stability of the power mod-
ule. For the test configuration in Figure 17, a 33 µF
electrolytic capacitor (ESR < 0.7 ¾ at 100 kHz)
mounted close to the power module helps ensure sta-
bility of the unit. For other highly inductive source
impedances, consult the factory for further application
guidelines.
Safety Considerations
For safety-agency approval of the system in which the
power module is used, the power module must be
installed in compliance with the spacing and separation
requirements of the end-use safety agency standard,
i.e., UL1950, CSA C22.2 No. 950-95, and VDE 0805
(EN60950, IEC950).
If the input source is non-SELV (ELV or a hazardous
voltage greater than 60 Vdc and less than or equal to
75 Vdc), for the module’s output to be considered
meeting the requirements of safety extra-low voltage
(SELV), all of the following must be true:
n
n
n
n
Note: Do not ground either of the input pins of the
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
The input to these units is to be provided with a maxi-
mum 20 A normal-blow fuse in the ungrounded lead.
The input source is to be provided with reinforced
insulation from any hazardous voltages, including the
ac mains.
One V
both the input and output pins are to be kept floating.
The input pins of the module are not operator acces-
sible.
Another SELV reliability test is conducted on the
whole system, as required by the safety agencies, on
the combination of supply source and the subject
module to verify that under a single fault, hazardous
voltages do not appear at the module’s output.
module without grounding one of the output pins.
This may allow a non-SELV voltage to appear
between the output pin and ground.
I
pin and one V
O
pin are to be grounded or
Lineage Power