JC100H Lineage Power, JC100H Datasheet
JC100H
Available stocks
Related parts for JC100H
JC100H Summary of contents
Page 1
... Description The JC050H, JC075H, JC100H Power Modules are dc-dc converters that operate over an input voltage range of 18 Vdc to 36 Vdc and provide a precisely regulated dc output. The outputs are fully isolated from the inputs, allow- ing versatile polarity configurations and grounding connections. The modules have maximum power ratings from 100 typical full-load efficiency of 86% ...
Page 2
... max JC050H (See Title 1.) JC075H (See Title 2.) JC100H (See Title 3.) Inrush Transient Input Reflected-ripple Current, Peak-to-peak ( MHz, 12 µH source impedance; see Figure 11.) Input Ripple Rejection (120 Hz) Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. ...
Page 3
... Isolation Resistance Lineage Power (continued) Device Symbol All All V All All All All All All JC050H JC075H JC100H JC050H I JC075H I JC100H I All JC050H JC075H JC100H = 25 °C max All All O, max All All Min Typ Max V 23.28 — 24.72 O 23.55 — 24.45 O, set — — 0.01 0.1 — ...
Page 4
... V O, clamp Tc March 2008 Typ Max Unit 3,000,000 hr. — 100 (3.5) g (oz.) Min Typ Max Unit 0 — 1.2 V — — 1.0 mA — — — — 50 µA — — — 2 — 110 %V O, nom 27.4 — 30.6 V — 105 — °C Lineage Power ...
Page 5
... March 2008 dc-dc Converters Vdc Input, 24 Vdc Output 100 W Characteristic Curves The following figures provide typical characteristics for the JC050H, JC075H, JC100H power modules. The figures are identical for both on/off configurations. 4 3.5 3 2.5 2 1 INPUT VOLTAGE, V Figure 1. Typical JC050H Input Characteristics at ...
Page 6
... OUTPUT CURRENT, I Figure 5. Typical JC075H Output Characteristics at Room Temperature 0.00.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 OUTPUT CURRENT, I Figure 6. Typical JC100H Output Characteristics at Room Temperature 86.5 86 85.5 85 84.5 84 83.5 83 82.5 82 81.5 81 80.5 80 79.5 79 78 (A) O 8-1287 (C) Figure 7. Typical JC050H Converter Efficiency vs. ...
Page 7
... 0.5 1 1.5 2 2.5 OUTPUT CURRENT, I Figure 9. Typical JC100H Converter Efficiency vs. Output Current at Room Temperature TIME ms/div) Figure 10.Typical Start-Up from Remote On/Off JCxxxH1 Full Load O Lineage Power Test Configurations TO OSCILLOSCOPE BATTERY = ...
Page 8
... If not using the remote on/off feature, do one of the fol- lowing: For negative logic, short ON/OFF pin For positive logic, leave ON/OFF pin open. n March 2008 (-) terminal (V ). The switch I on/off = 1.2 V. The maximum I on/off generated by on/off = μA. on/off (-). I Lineage Power on/off ...
Page 9
... I O CONTACT RESISTANCE Figure 15. Effective Circuit Configuration for Single-Module Remote-Sense Operation Lineage Power Output Voltage Set-Point Adjustment (Trim) Output voltage trim allows the user to increase or decrease the output voltage set point of a module. This is accomplished by connecting an external resistor between the TRIM pin and either the SENSE(+) or SENSE(– ...
Page 10
... Heat is removed by conduc- tion, convection, and radiation to the surrounding environment. Proper cooling can be verified by mea- suring the case temperature. Peak temperature (Tc) occurs at the position indicated in Title 20. March 2008 PERCENT CHANGE IN OUTPUT VOLTAGE (Δ%) Voltage Lineage Power 8-1294 (C) ...
Page 11
... The use of Title 21 is shown in the following example. (–) Example What is the minimum airflow necessary for a JC100H 8-716 (C).f operating at nominal line, an output current of 4.2 A, and a maximum ambient temperature of 40 °C? Solution ...
Page 12
... Figure 24. JC100H Power Dissipation vs. 1.2 1.4 1.6 1.8 2 (A) O 8-11182 (C).a Heat Transfer with Heat Sinks The power modules have through-threaded 0.5 mounting holes, which enable heat sinks or cold plates to attach to the module. The mounting torque must not exceed 0.56 N–m (5 in.-lb.). ...
Page 13
... Then solve the following equation: 2.0 2.5 3.0 (400) (500) (600) θ ca 8-1153 θ ca θ ca Use Title 25 to determine air velocity for the 0.5 inch heat sink. The minimum airflow necessary for the JC100H module is 1.1 m/s (220 ft./min.). = 4 ° ° using Title 24 – ...
Page 14
... This equation pro- T vides a conservative estimate for such instances. A θsa Layout Considerations 8-1304 Copper paths must not be routed beneath the power module mounting inserts. March 2008 ( ) T – θ cs ------------------------ - – Lineage Power ...
Page 15
... SIDE LABELS* 1.02 (0.040) DIA SOLDER-PLATED BRASS 7 PLCS 12.7 (0.50) V (–) V (– 10.16 (0.400) CASE –SEN TRIM ON/OFF +SEN V (+) V (+) I O 48.26 (1.900) 4.8 48.3 (1.90) (0.19) March 2008 2.06 (0.081) DIA SOLDER-PLATED BRASS, 2 PLACES–(OUTPUT AND +OUTPUT) MOUNTING INSERTS M3x0.5 THROUGH, 4 PLCS 10.16 (0.400) 17.78 (0.700) 25.40 (1.000) 35.56 (1.400) Lineage Power 8-1190 (C) ...
Page 16
... Optional features can be ordered using the suffixes shown in Title 4. The suffixes follow the last letter of the device code and are placed in descending order. For example, the device codes for a JC100H module with the following options are shown below: Positive logic Negative logic Positive logic and 2 ...
Page 17
... March 2008 dc-dc Converters Vdc Input, 24 Vdc Output 100 W Notes Lineage Power 17 ...
Page 18
... Lineage Power reserves the right to make changes to the product(s) or information contained herein without notice. No liability is assumed as a result of their use or application. No rights under any patent accompany the sale of any such pr oduct(s) or information. © 2008 Lineage Power Corpor ation, (Mesquite, Texas) All International Rights Reser ved. ...