QHW100G1 Lineage Power, QHW100G1 Datasheet

no-image

QHW100G1

Manufacturer Part Number
QHW100G1
Description
Manufacturer
Lineage Power
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
QHW100G1
Manufacturer:
TYCO
Quantity:
726
Data Sheet
April 2008
Description
The QHW050G1, QHW075G1, and QHW100G1 Power Modules are dc-dc converters that operate over an
input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully iso-
lated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have
maximum power ratings from 25 W to 50 W at a typical full-load efficiency of 86%.
The sealed modules offer a metal baseplate for excellent thermal performance. Threaded-through holes are pro-
vided to allow easy mounting or addition of a heat sink for high-temperature applications. The standard feature set
includes remote sensing, output trim, and remote on/off for convenient flexibility in distributed power applications.
The QHW Series Power Modules use advanced, surface-
mount technology and deliver high-quality, efficient, and
compact dc-dc conversion.
Applications
n
n
n
Options
n
n
n
n
dc-dc Converters: 36 to 75 Vdc Input, 2.5 Vdc Output; 25 W to 50 W
Distributed power architectures
Communications equipment
Computer equipment
Heat sinks available for extended operation
Auto-restart after overtemperature, overvoltage, or
overcurrent shutdown
Choice of short pin lengths
Case ground pin
QHW050G1, QHW075G1, and QHW100G1 Power Modules;
Features
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
* ISO is a registered trademark of the International Organization
† UL is a registered trademark of Underwriters Laboratories, Inc.
‡ CSA is a registered trademark of Canadian Standards Associa-
§ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** This product is intended for integration into end-use equipment.
for Standardization.
tion.
All the required procedures for CE marking of end-use equip-
ment should be followed. (The CE mark is placed on selected
products.)
Small size: 36.8 mm x 57.9 mm x 12.7 mm
High power density
High efficiency: 86% typical
Low output noise
Constant frequency
Industry-standard pinout
Metal baseplate
2:1 input voltage range
Overtemperature, overvoltage and overcurrent
protection
Negative remote on/off
Remote sense
Adjustable output voltage
ISO* 9001 and ISO 14001 Certified manufacturing
facilities
UL
Certified, and VDE
CE mark meets 73/23/EEC and 93/68/EEC direc-
tives**
60950 Recognized, CSA
(1.45 in. x 2.28 in. x 0.50 in.)
§
0805 (IEC60950) Licensed
C22.2 No. 60950-00

Related parts for QHW100G1

QHW100G1 Summary of contents

Page 1

... Description The QHW050G1, QHW075G1, and QHW100G1 Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a precisely regulated dc output. The outputs are fully iso- lated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from typical full-load efficiency of 86% ...

Page 2

... max QHW050G1 QHW075G1 QHW100G1 Inrush Transient Input Reflected-ripple Current, Peak-to-peak ( MHz, 12 µH source impedance; see Figure 15.) Input Ripple Rejection (100—120 Hz) Fusing Considerations CAUTION: This power module is not internally fused. An input line fuse must always be used. ...

Page 3

... Isolation Capacitance Isolation Resistance Lineage Power (continued) Device Symbol All All All All All All All All QHW050G1 QHW075G1 QHW100G1 QHW050G1 QHW075G1 QHW100G1 = 70 °C; QHW050G1 C QHW075G1 QHW100G1 All = 25 ° max All All : O, max All All Min Typ Max V 2.46 2.5 2.54 O, set V 2.42 — 2.58 O — ...

Page 4

... April 2008 Typ Max 2,341,000 hours — 75 (2.7) g (oz.) Min Typ Max 0 — 1.2 — — 1.0 — — 15 — — 50 — — — 0.5 90 — 110 %V 3.0* — 3.4* — 105 — C Lineage Power Unit Unit µ nom V °C ...

Page 5

... INPUT VOLTAGE, V Figure 2. Typical QHW075G1 Input Characteristics at 25 °C Lineage Power 2.5 2 1.5 1 0.5 0 (V) I 1-0001 Figure 3. Typical QHW100G1 Input Characteristics (V) I 1-0002 Figure 4. Typical QHW050G1 Converter Efficiency ...

Page 6

... OUTPUT CURRENT, I Figure 6. Typical QHW100G1 Converter Efficiency vs. Output Current at 25 ° (A) O 1-0004 Note: See Figure 16 for test conditions. Figure 7. Typical QHW050G1, QHW075G1 ...

Page 7

... A TIME, t (100 µs/div) Note: Tested with a 220 µF aluminum and a 1.0 µF ceramic capacitor across the load. Figure 10. Typical QHW100G1 Transient Response to Step Increase in Load from 50% to 75% of Full Load at Room Temperature and 48 Vdc Input (Waveform Averaged to Eliminate Ripple Component.) Lineage Power 5 ...

Page 8

... A TIME, t (100 µs/div) Note: Tested with a 220 µF aluminum and a 1.0 µF ceramic capacitor across the load. Figure 13. Typical QHW100G1 Transient Response to Step Decrease in Load from 50% to 25% of Full Load at Room Temperature and 48 Vdc Input (Waveform Averaged to Eliminate Ripple Component.) TIME ms/div) Note: Tested with a 220 µ ...

Page 9

... The power module has extra-low voltage (ELV) outputs when all inputs are ELV. The input to these units provided with a maxi- mum 20 A normal-blow fuse in the ungrounded lead. Lineage Power Feature Descriptions Overcurrent Protection To provide protection in a fault (output overload) condi- ...

Page 10

... Single-Module Remote-Sense Operation ), the output voltage set point adj-down 511 ⎛ ⎞ kΩ = --------- - 10.22 – ⎝ ⎠ Δ% ), the output voltage set adj-up ) increases (see Figure 21). ( Δ% ) 511 5.11V 100 + ⎛ O – = ------------------------------------------------- - --------- - 10.22 – ⎝ Δ% 1.225Δ% Lineage Power 8-651 (F).m ⎞ kΩ ⎠ ...

Page 11

... ON/OFF SENSE(+) CASE TRIM V (–) SENSE(– (–) O Figure 20. Circuit Configuration to Decrease Output Voltage Lineage Power V (+) I ON/OFF CASE (–) terminals O V (–) I Figure 21. Circuit Configuration to Increase Note: The output voltage of this module may be increased by a maximum of 0.5 V. The 0 the combination of both the remote-sense and the output voltage set-point adjustment (trim) ...

Page 12

... The use of Figure 23 is shown in the following example. Example What is the minimum airflow necessary for a QHW100G1 operating transverse orientation, and a maximum ambient C temperature of 55 °C? Solution ...

Page 13

... NATURAL 3 CONVECTION 2 1 Figure 26. QHW075G1 Power Dissipation vs 100 (° 8-2318 (F). Figure 27. QHW100G1 Power Dissipation vs (A) O 1-0063 ...

Page 14

... IN. HEAT SINK 0 0.5 1.0 1.5 2.0 (100) (200) (300) (400) VELOCITY, m/s (ft./min.) Curves; Longitudinal Orientation 1 IN. HEAT SINK 1/2 IN. HEAT SINK 1/4 IN. HEAT SINK NO HEAT SINK LOCAL AMBIENT TEMPERATURE, T Natural Convection; Transverse Orientation Lineage Power April 2008 2.5 3.0 (500) (600) 8-2324 ( 100 (°C) A 8-2889 (F) ...

Page 15

... The use of Figure 28 is shown in the following example. Example °C case temperature is desired, what is the minimum airflow necessary? Assume the QHW100G1 module is operating maximum ambient air temperature of 40 °C, and the heat sink is 1/4 inch. The module is oriented in the transverse direction ...

Page 16

... FLTR100V10 Filter Module Data Sheet (DS99-294EPS). Layout Considerations Copper paths must not be routed beneath the power module mounting inserts. For additional layout guide- lines, refer to the FLTR100V10 Filter Module Data Sheet (DS99-294EPS θ sa 8-1304 (F).e April 2008 ( ) T – θ cs ------------------------ - – Lineage Power ...

Page 17

... Top View Side View 4.1 (0.16) MIN, Bottom View 3.6 (0.14) 5.3 (0.21) (0.600) 26.16 (1.030) (0.300) * Side label includes Lineage name, product designation, safety agency markings, input/output voltage and current ratings, and bar code. Lineage Power 36.8 (1.45) 57.9 (2.28) 12.7 (0.50) 0.51 (0.020) 3.5 (0.14) MIN 6 PLACES 1.02 (0.040) DIA SOLDER-PLATED BRASS, 6 PLACES RIVETED CASE PIN (OPTIONAL) 1 ...

Page 18

... Vdc Optional features can be ordered using the suffixes shown in Table 5. To order more than one option, list device codes suffixes in numerically descending order. For example, the device code for a QHW100G1 module with the following option is shown below: Negative logic and auto-restart after overtemperature, overvoltage, or overcurrent shutdown Table 5 ...

Page 19

... Dimensions are in millimeters and (inches). 57.91 ± 0.38 (2.280 ± 0.015) 26.16 ± 0.13 (1.030 ± 0.005) Figure 35. Longitudinal Heat Sink Lineage Power 1/4 IN. 36.83 ± 0.38 (1.450 ± 0.015) 1/2 IN. 1 IN. 8-2473 (F) Comcode ...

Page 20

... Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any oduct information. ...

Related keywords