FEATURES
DESCRIPTION
The NPH25S series of DC-DC Converters
combines ease of application with versatility.
The pin pattern is based on the popular
industry standard, but two additional pins
may optionally be fitted to provide a variety
of features not commonly found on units of
this type. High efficiency enables full rating to
be achieved in a small package without
heatsinking, and a high surge capability will
provide for start-up and transient loads, whilst
being thermally protected against sustained
overload. Overload protection of the
“constant current” type ensures start-up
into complex load conditions. The copper
case achieves efficient heat transfer and
screening. The product range has been
recognised by Underwriters Laboratory (UL)
to UL 1950 for operational insulation, file
number E179522 applies.
www.cdpoweronline.com
High Efficiency to 89%
Power Density up to 1.78W/cm
(28W/in
1.5kV Input to Output Isolation
Industry Standard Pinout
UL 1950 Recognised
Non Latching Current Limit
Constant 350kHz Frequency
Versatile Control Options
Continuous Rating to 30W at 60°C
Without Heatsink
Operation to Zero Load
Protected Against All Load Faults
Internal Over Temperature Protection
Uses No Electrolytic Capacitors
UL 94V-0 Package Materials
3
)
3
1 1 If optional pins ADJ and SS are required (as indicated in the pin connections diagram) prefix the ending “i” with
2 A minimum load of 10% of rating is recommended for typical applications.
3 Optional where fitted.
4 Absolute maximum value for 30 seconds. Prolonged operation may damage the product.
SELECTION GUIDE
Order Code
NPH25S2403i
NPH25S2405i
NPH25S2412i
NPH25S2415i
NPH25S4803i
NPH25S4805i
NPH25S4812i
NPH25S4815i
INPUT CHARACTERISTICS
Parameter
Voltage Range
OUTPUT CHARACTERISTICS
Parameter
Voltage Set
Point Error
Overall
Voltage Error
Temperature Coefficient
of Output Voltage
(slope)
Deviation of
Output Voltage
Line Regulation
Load Regulation
Ripple
CONTROL CHARACTERISTICS
Parameter
Voltage Trimming
Range
Remote Switch Input
(voltage relative
to input negative)
Start Delay
Synchronisation
Switching Frequency
ABSOLUTE MAXIMUM RATINGS
Input voltage, 24V input types
Input voltage, 48V input types
Output Voltage
Output trim control
Synchronisation/shutdown control
ISOLATION CHARACTERISTICS
Parameter
Isolation Voltage
Resistance
an E when ordering, e.g. NPH25S4803Ei.
All specifications typical at T A =25°C, nominal input voltage and rated output current unless otherwise specified.
1
3
Conditions
Continuous operation, 24V input types
Continuous operation, 48V input types
Input Voltage
3
Nominal
Conditions
At rated load,
Trim control at either output
Not operating
Operating, open circuit voltage
Time from application of valid input
voltage to output being in specification
Specified drive signal
Conditions
50% load
Case temperature –40°C to 110°C
Load 0% - 100%
Input specified range
Temperature MIN-MAX
Operating voltage range, 50% load
0% - 100% rated load
rms
Isolated 25W Single Output DC-DC Converters
24
24
24
24
48
48
48
48
(V)
Conditions
Flash tested for 1 second
Viso=500VDC
Voltage
Output
12.1
15.1
12.1
15.1
3.4
5.1
3.4
5.1
(V)
2
NPH25S SERIES
–0.5V to 40V
–0.5V to 80V
–0.3V to regulated voltage
–1V to +30V
±15V relative to input return
MIN
Current
18
36
Output
MIN
MIN
±10
320
330
1500
-15
7.3
5.0
2.1
1.7
7.3
5.0
2.1
1.7
MIN
(A)
9
1
NOM
24
48
4000
TYP
350
0.5
TYP
70
10
25
TYP
0
4
4
MAX
MAX
36
75
MAX
250
MAX
440
395
0.5
2.5
0.1
0.5
1.5
Efficiency
11
50
1
(%)
81
84
86
87
83
85
88
89
ppm°C
Units
Units
Units
Units
VDC
kHz
kHz
GΩ
mV
mS
%
%
%
%
%
%
V
V

Related parts for NPH25S2412I

NPH25S2412I Summary of contents

Page 1

... Underwriters Laboratory (UL 1950 for operational insulation, file number E179522 applies. www.cdpoweronline.com Isolated 25W Single Output DC-DC Converters SELECTION GUIDE Nominal Input Voltage Order Code (V) 1 NPH25S2403i 24 NPH25S2405i 24 NPH25S2412i 24 NPH25S2415i 24 NPH25S4803i 48 NPH25S4805i 48 NPH25S4812i 48 NPH25S4815i 48 INPUT CHARACTERISTICS Parameter Conditions Continuous operation, 24V input types ...