JAW075B Lineage Power, JAW075B Datasheet
JAW075B
Related parts for JAW075B
JAW075B Summary of contents
Page 1
... Description The JAW050B and JAW075B Power Modules are dc-dc converters that operate over an input voltage range of 36 Vdc to 75 Vdc and provide a regulated dc output. The outputs are fully isolated from the inputs, allowing versatile polarity configurations and grounding connections. The modules have maximum power ratings from typical full-load efficiency of 86% ...
Page 2
... Table 1. Input Specifications Parameter Operating Input Voltage Maximum Input Current max JAW050B1 (See Figure 1.) JAW075B1 (See Figure 2 max JAW050B1 JAW075B1 Inrush Transient Input Reflected-ripple Current, Peak-to-peak ( MHz, 12 µH source impedance; ...
Page 3
... Vdc to 75 Vdc Input, 12 Vdc Output (continued) Device Symbol All V All All All All All All All JAW050B JAW075B JAW050B JAW075B = 250 mV) All °C; JAW050B C JAW075B All = 25 ° max All All : O, max All All Min Typ Max 11.78 12.0 12.22 O, set V 11.64 — 12.36 O — ...
Page 4
... April 2008 Typ Max 3,000,000 hours — 100 (3.5) g (oz.) Min Typ Max 0 — 1.2 — — 1.0 — — 15 — — 50 — — — 0.5 70 — 110 %V 13.2* — 15.5* — 105 — C Lineage Power Unit Unit µ nom V °C ...
Page 5
... Figure 3. Typical JAW050B1 Efficiency vs. Output 6. 3.125 0.625 0 (V) I 8-3217 (F).a Figure 4. Typical JAW075B1 Efficiency vs. Output 0.9 1.4 1.9 2.4 2.9 3.4 OUTPUT CURRENT, I (A) O Current at Room Temperature ...
Page 6
... 6. TIME μs/div) Note: See Figure 12 for test conditions. Figure 5. Typical JAW075B1 Output Ripple Voltage at Room Temperature and 48 Vdc Input 2.1 A TIME, t (50 μs/div) Note: Tested without any load capacitance. Figure 6. Typical JAW050B1 Transient Response to Step Increase in Load from 50% to 75% ...
Page 7
... Full Load at Room Temperature and 48 Vdc Input (Waveform Averaged to Eliminate Ripple Component TIME, t (20 ms/div) Note: Tested without any load capacitance. Figure 10. JAW075B1 Typical Start-Up from Remote On/Off Lineage Power 36 Vdc to 75 Vdc Input, 12 Vdc Output Test Configurations BATTERY ...
Page 8
... V on/off If not using the remote on/off feature, do one of the following: For negative logic, short the ON/OFF pin For positive logic, leave the ON/OFF pin open. n April 2008 ). The on/off generated by on/off = µA. (–). I Lineage Power ...
Page 9
... Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. Lineage Power 36 Vdc to 75 Vdc Input, 12 Vdc Output SUPPLY CONTACT ...
Page 10
... Note: Top view, pin locations are for reference only. Measurements shown are in millimeters and (inches). Figure 18. Case Temperature Measurement April 2008 V (+) V (+) I O ON/OFF + SEN TRIM CASE – SEN V (–) V (– MEASURE CASE TEMPERATURE HERE 14.2 (0.56) Location Lineage Power ) C 8-3228 (F) ...
Page 11
... Lineage Power 36 Vdc to 75 Vdc Input, 12 Vdc Output (continued 0.4 Figure 19. JAW050B1 Power Dissipation vs 0.6 Figure 20. JAW075B1 Power Dissipation vs 0.9 1.4 1.9 2.4 2.9 3.4 3.9 OUTPUT CURRENT, I (A) O Output Current ...
Page 12
... The use of Figure 22 is shown in the following example. Example °C case temperature is desired, what is the minimum airflow necessary? Assume the JAW075B1 module is operating divided by the 6.2 A, longitudinal orientation, maximum ambient air temperature of 40 °C, and the heat sink is 1/4 inch. ...
Page 13
... θ cs Figure 23. Resistance from Case-to-Sink and Sink-to-Ambient Lineage Power 36 Vdc to 75 Vdc Input, 12 Vdc Output For a managed interface using thermal grease or foils, (continued) a value of θcs = 0.1 °C/W to 0.3 °C/W is typical. The solution for heat sink resistance is: (continued) θ ...
Page 14
... DIA SOLDER-PLATED BRASS, 7 PLACES 7.1 STANDOFF, (0.28) 4 PLACES 12.7 (0.50) V (−) V (− 10.16 (0.400) CASE −SEN TRIM ON/OFF +SEN V (+) V (+) I O 48.26 (1.900) 4.8 48.3 (1.90) (0.19) April 2008 2.06 (0.081) DIA SOLDER- PLATED BRASS, 2 PLACES (+)) (V (−) AND MOUNTING INSERTS M3 x 0.5 THROUGH, 4 PLACES 7.1 (0.28) 10.16 17.78 (0.400) (0.700) 25.40 (1.000) 35.56 (1.400) Lineage Power 8-716(F).j ...
Page 15
... I O +SEN ON/OFF TRIM −SEN CASE 10.16 (0.400) V (−) V (− 12.7 (0.50) MODULE OUTLINE Output Remote On/Off Current Logic 50 W 4.2 A Negative 75 W 6.25 A Negative 50 W 4.2 A Positive 75 W 6.25 A Positive 61.0 (2.40) 35.56 (1.400) 25.40 (1.000) 17.78 10.16 (0.700) (0.400) Device Comcode Code JAW050B1 108449398 JAW075B1 TBD JAW050B TBD JAW075B TBD 8-716(F).j 15 ...
Page 16
... Lineage Power reserves the right to make changes to the produc t(s) or information contained herein without notice. No liability is ass umed as a res ult of their use or applic ation. No rights under any patent acc ompany the sale of any oduct information. ...