PS22054 Mitsumi Electronics, Corp., PS22054 Datasheet

no-image

PS22054

Manufacturer Part Number
PS22054
Description
Manufacturer
Mitsumi Electronics, Corp.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PS22054
Manufacturer:
MITSUBISHI
Quantity:
56
Part Number:
PS22054
Quantity:
452
Part Number:
PS22054
Manufacturer:
MITSUBISHI/三菱
Quantity:
20 000
Part Number:
PS22054-P
Manufacturer:
MITSUBISHI
Quantity:
56
APPLICATION
AC400V 0.2kW~2.2kW inverter drive for small power motor control.
PS22054
Fig. 1 PACKAGE OUTLINES
INTEGRATED DRIVE, PROTECTION AND SYSTEM CONTROL FUNCTIONS
• For upper-leg IGBT
• For lower-leg IGBT
• Fault signaling : Corresponding to an SC fault (Lower-side IGBT) or a UV fault (Lower-side supply).
• Input interface : 5V line CMOS/TTL compatible (High active logic).
2- 4.5
0.2
All external terminals are treated with lead free solder (ingredient : Sn-Cu) plating.
1 2
2.54
8
S
0.3
S
3 4
(2.5)
22
: Drive circuit, Control supply under-voltage protection (UV), Short circuit protection (SC).
:Drive circuit, High voltage high-speed level shifting, Control supply under-voltage (UV) protection.
0.3
Type name , Lot No.
5 6
23
10.16
30 2.54(=76.2)
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
7 8
24
0.3
67
79
MITSUBISHI SEMICONDUCTOR <Dual-In-Line Package Intelligent Power Module>
0.3
0.5
9 10
Heat sink side
25
QR
Code
11 12 13 14 15 16 17 18 19 20 21
26
27
28
INTEGRATED POWER FUNCTIONS
1200V/15A low-loss 4
for 3 phase DC-to-AC power conversion
Detail : A
(2)
A
Heat sink side
th
generation IGBT inverter bridge
TRANSFER-MOLD TYPE
TRANSFER-MOLD TYPE
1. VUFS
2. VUFB
3. VP1
4. UP
5. VVFS
6. VVFB
7. VP1
8. VP
9. VWFS
10. VWFB
11. VP1
12. VPC
13. WP
14. VN1
15. VNC
16. CIN
17. CFO
18. FO
19. UN
20. VN
21. WN
PS22054
INSULATED TYPE
INSULATED TYPE
22. P
23. U
24. V
25. W
26. NU
27. NV
28. NW
PS22054
Dimensions in mm
May 2005

Related parts for PS22054

PS22054 Summary of contents

Page 1

... All external terminals are treated with lead free solder (ingredient : Sn-Cu) plating. TRANSFER-MOLD TYPE INTEGRATED POWER FUNCTIONS th 1200V/15A low-loss 4 generation IGBT inverter bridge for 3 phase DC-to-AC power conversion Heat sink side (2) Detail : A PS22054 PS22054 TRANSFER-MOLD TYPE INSULATED TYPE INSULATED TYPE Dimensions VUFS 22 VUFB 23 VP1 24 25 VVFS 26 ...

Page 2

... When the sensed shunt voltage exceeds the SC trip-level, all the L-side IGBTs are turned OFF and a fault signal (Fo) is output. Since the SC fault may be repetitive recommended to stop the system and check the fault, when the Fo signal is received. PS22054 TRANSFER-MOLD TYPE INSULATED TYPE C2 ...

Page 3

... Sink current at F terminal O Applied between CIN-V NC Condition V = 13.5~16.5V, Inverter part 125 C, non-repetitive, less than (Note 2) 60Hz, Sinusoidal minute, connection pins to heat-sink plate Heat-sink T C PS22054 TRANSFER-MOLD TYPE INSULATED TYPE Ratings Unit 900 V 1000 V 1200 56.8 W –20~+125 ...

Page 4

... C j Trip level Reset level = 22nF (Note according to the following approximate equation : C FO PS22054 TRANSFER-MOLD TYPE INSULATED TYPE Limits Unit Min. Typ. Max. — — 1.76 C/W — — 2.41 C/W — — 0.047 C/W Limits Unit Min. ...

Page 5

... C, T 100 C (Note (Note 8) V 800V 15A V 16.5V 16.5V 100 < Ic (Note 9) -NU, NV, NW (including surge) NC PS22054 TRANSFER-MOLD TYPE INSULATED TYPE Limits Unit Min. Typ. Max. — 0.98 1.47 N·m — — — m –50 100 Limits Unit Min. Typ. ...

Page 6

... COM S HVIC3 V V IGBT3 Di3 COM S IGBT4 LVIC Di4 U OUT IGBT5 Di5 V OUT IGBT6 N Di6 OUT CIN GND CFO CFO CIN PS22054 TRANSFER-MOLD TYPE INSULATED TYPE May 2005 ...

Page 7

... SC reference voltage CR circuit time constant DELAY the circuits start to operate when next input is applied. Dr pulse is not less than the fixed width for very short UV interval. O RESET SET PS22054 TRANSFER-MOLD TYPE INSULATED TYPE RESET b6 b7 May 2005 ...

Page 8

... NU Shunt resistor NV NW Please make the wiring connection of shunt resistor to GND as short as Please insert fast possible. recovery type diode between V and NC NU, NV, NW terminals. PS22054 TRANSFER-MOLD TYPE INSULATED TYPE RESET May 2005 ...

Page 9

... – logic Vref circuit – Vref R + Shunt C resistor – Vref Comparator PS22054 TRANSFER-MOLD TYPE INSULATED TYPE this wiring is too NW long, short circuit might be caused Shunt resistor N1 terminals. (Example : NC and NU, NV May 2005 ...