AN1006
Power Rectifiers
The rectifier is a unidirectional device which conducts when for-
ward voltage (above 0.7 V) is applied.
To connect the rectifier:
1. Connect Anode to Collector Terminal (C).
2. Connect Cathode to Emitter Terminal (E).
To begin testing, perform the following procedures.
Procedure 1: V
To measure the V
1. Set Variable Collector Supply Voltage Range to 1500 V.
2. Set Horizontal knob to sufficient scale to allow viewing of
3. Set Mode to Leakage.
4. Set Vertical knob to 100 µA/DIV. (Due to leakage setting, the
5. Set Terminal Selector to Emitter Grounded-Open Base.
6. Set Polarity to (–).
7. Set Power Dissipation to 2.2 W. (2 W on 370)
8. Set Left-Right Terminal Jack Selector to correspond with
9. Increase Variable Collector Supply Voltage to the rated
Procedure 2: V
Before testing, note the following:
http://www.teccor.com
+1 972-580-7777
(2000 V on 370)
trace at the required voltage level (100 V/DIV for 400 V and
600 V devices and 50 V/DIV for 200 V devices).
CRT readout will be 100 nA per division.)
location of test fixture.
V
across horizontally from the dot to the vertical current scale.
This measured value is the leakage current.
(Figure AN1006.2)
A Kelvin test fixture is required for this test. If a Kelvin fixture is
not used, an error in measurement of VFM will result due to
voltage drop in fixture. If a Kelvin fixture is not available,
Figure AN1006.3 shows necessary information to wire a test
fixture with Kelvin connections.
Due to the current limitations of standard curve tracer
model 576, V
Figure AN1006.2
RRM
of the device and observe the dot on the CRT. Read
I RM
FM
RRM
FM
RRM
cannot be tested at rated current without a Tek-
and I
and I
I
RM
= 340 nA at V
RM
RM
parameter:
V RRM
RRM
= 600 V
PER
PER
PER
DIV
DIV
PER
DIV
DIV
V
E
R
H
O
R
S
E
P
()k
9m
T
Z
T
I
100
100
nA
V
AN1006 - 4
Figure AN1006.3
To measure the V
1. Set Variable Collector Supply Voltage Range to 15 Max
2. Set Horizontal knob to 0.5 V/DIV.
3. Set Mode to Norm.
4. Set Vertical knob to 2 A/DIV.
5. Set Power Dissipation to 220 W (100 W on 577).
6. Set Polarity to (+).
7. Set Left-Right Terminal Jack Selector to correspond with
8. Increase Variable Collector Supply Voltage until current
WARNING: Limit test time to 15 seconds maximum.
To measure V
the trace crosses the 20 A axis. The distance from the left-hand
side of scale to the crossing point is the V
(Figure AN1006.4)
Note: Model 370 current is limited to 10 A.
Base (B), and
Collector (C),
pins wired to
tronix model 176 high-current module. The procedure below is
done at I
use of a standard curve tracer and still provides an estimate of
whether V
Peak Volts. (16 V on 370)
location of test fixture.
reaches 20 A.
Emitter (E)
One set of
Terminals
T(RMS)
FM
FM
, follow along horizontal scale to the point where
is within specification.
Instructions for Wiring Kelvin Socket
FM
= 10 A (20 A
parameter:
The pins which correspond to
the anode and cathode of the
device are wired to the terminals
marked C
E
does not require a Kelvin
connection.
SENSE
PK
(MT1/Cathode). The gate
). This test parameter allows the
SENSE
(MT2/Anode) and
©2002 Teccor Electronics
Thyristor Product Catalog
FM
Socket used
must have two
sets of pins
value.
SOCKET PINS
Application Notes