P87C54SBPN NXP Semiconductors, P87C54SBPN Datasheet - Page 18

no-image

P87C54SBPN

Manufacturer Part Number
P87C54SBPN
Description
MCU 8-Bit 87C 80C51 CISC 16KB EPROM 3.3V/5V 40-Pin PDIP Tube
Manufacturer
NXP Semiconductors
Datasheet

Specifications of P87C54SBPN

Package
40PDIP
Device Core
80C51
Family Name
87C
Maximum Speed
16 MHz
Ram Size
256 Byte
Program Memory Size
16 KB
Operating Supply Voltage
3.3|5 V
Data Bus Width
8 Bit
Program Memory Type
EPROM
Number Of Programmable I/os
32
Interface Type
UART
Operating Temperature
0 to 70 °C
Number Of Timers
3

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
P87C54SBPN
Manufacturer:
NXP
Quantity:
382
Part Number:
P87C54SBPN
Manufacturer:
PHI
Quantity:
1 000
Part Number:
P87C54SBPN
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
When Timer 2 is in the baud rate generator mode, one should not try
1. Capture/reload occurs only on timer/counter overflow.
2. Capture/reload occurs on timer/counter overflow and a 1-to-0 transition on T2EX (P1.1) pin except when Timer 2 is used in the baud rate
Philips Semiconductors
to read or write TH2 and TL2. As a baud rate generator, Timer 2 is
incremented every state time (osc/2) or asynchronously from pin T2;
under these conditions, a read or write of TH2 or TL2 may not be
accurate. The RCAP2 registers may be read, but should not be
written to, because a write might overlap a reload and cause write
and/or reload errors. The timer should be turned off (clear TR2)
before accessing the Timer 2 or RCAP2 registers.
Table 5 shows commonly used baud rates and how they can be
obtained from Timer 2.
Summary Of Baud Rate Equations
Timer 2 is in baud rate generating mode. If Timer 2 is being clocked
through pin T2(P1.0) the baud rate is:
Table 6. Timer 2 as a Timer
Table 7. Timer 2 as a Counter
NOTES:
2000 Aug 07
80C51 8-bit microcontroller family
8K–64K/256–1K OTP/ROM/ROMless, low voltage (2.7V–5.5V),
low power, high speed (33MHz)
16-bit Auto-Reload
16-bit Capture
Baud rate generator receive and transmit same baud rate
Receive only
Transmit only
16-bit
Auto-Reload
generator mode.
Baud Rate + Timer 2 Overflow Rate
16
MODE
MODE
18
If Timer 2 is being clocked internally , the baud rate is:
Where f
To obtain the reload value for RCAP2H and RCAP2L, the above
equation can be rewritten as:
Timer/Counter 2 Set-up
Except for the baud rate generator mode, the values given for
T2CON do not include the setting of the TR2 bit. Therefore, bit TR2
must be set, separately, to turn the timer on. See Table 6 for set-up
of Timer 2 as a timer. Also see Table 7 for set-up of Timer 2 as a
counter.
INTERNAL CONTROL
INTERNAL CONTROL
Baud Rate +
RCAP2H, RCAP2L + 65536 *
(Note 1)
(Note 1)
OSC
00H
01H
34H
24H
14H
02H
03H
= Oscillator Frequency
8XC51RA+/RB+/RC+/RD+/80C51RA+
[32
[65536 * (RCAP2H, RCAP2L)]]
T2CON
TMOD
8XC51FA/FB/FC/80C51FA
f
OSC
EXTERNAL CONTROL
EXTERNAL CONTROL
32
Baud Rate
f
OSC
(Note 2)
(Note 2)
0AH
0BH
08H
09H
36H
26H
16H
Product specification
8XC54/58

Related parts for P87C54SBPN