Specifications of A5347CA

Operating Temperature (min)
0C
Operating Temperature Classification
Commercial
Operating Temperature (max)
50C
Package Type
PDIP
Rad Hardened
No
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
A5347CA
Manufacturer:
ALLEGRO/雅丽高
Quantity:
20 000
TIMER START
TIMING RES.
LOW-V SET
TIMER OUT
FEEDBACK
Supply Voltage Range,
Input Voltage Range,
Input Current, I
Operating Temperature Range,
Storage Temperature Range,
CAUTION: CMOS devices have input static
protection but are susceptible to damage when
exposed to extremely high static electrical
charges.
+ SUPPLY
ABSOLUTE MAXIMUM RATINGS
(Voltages are referenced to V
V
V
T
T
LED
I / O
A
S
DD
IN
..................................... 0 C to +50 C
............................... -55 C to +125 C
........................ -0.3 V to V
................................ -0.5 V to +15 V
1
2
3
4
5
6
7
8
V
DD
IN
............................... 10 mA
DRIVER
OSC. &
TIMING
LOGIC
HORN
V
SS
16
15
14
13
12
11
10
9
DD
GUARD
GUARD
DETECT. IN
SENSITIVITY
SET
OSC. CAP.
HORN
HORN
– SUPPLY
SS
+ 0.3 V
Dwg. PC-004
)
1
2
1
2
WITH INTERCONNECT AND TIMER
5347
required features for an ionization-type smoke detector. A networking
capability allows as many as 125 units to be interconnected so that if
any unit senses smoke, all units will sound an alarm. In addition,
special features are incorporated to facilitate alignment and test of the
finished smoke detector. This device is designed to comply with
Underwriters Laboratories Specification UL217.
a minimum by powering down the device for 1.66 seconds and sensing
smoke for only 10 ms. Every 24 on/off cycles, a check is made for low
battery condition. By substituting other types of sensors, or a switch
for the ionization detector, this very-low power device can be used in
numerous other battery-operated safety/security applications.
package. It is rated for continuous operation over the temperature
range of 0 C to +50 C.
Always order by complete part number: A5347CA .
FEATURES
Interconnect Up to 125 Detectors
Piezoelectric Horn Driver
Guard Outputs for Detector Input
Pulse Testing for Low Battery
Power-ON Reset
Internal Timer & Control for Reduced Sensitivity
Built-In Hysteresis Reduces False Triggering
The A5347CA is a low-current, CMOS circuit providing all of the
The internal oscillator and timing circuitry keeps standby power to
The A5347CA is supplied in a low-cost, 16-pin dual in-line plastic
SMOKE DETECTOR

Related parts for A5347CA

A5347CA Summary of contents

Page 1

... WITH INTERCONNECT AND TIMER The A5347CA is a low-current, CMOS circuit providing all of the required features for an ionization-type smoke detector. A networking capability allows as many as 125 units to be interconnected so that if 2 any unit senses smoke, all units will sound an alarm. In addition, special features are incorporated to facilitate alignment and test of the finished smoke detector ...

Page 2

SMOKE DETECTOR with INTERCONNECT and TIMER FUNCTIONAL BLOCK DIAGRAM AND TYPICAL APPLICATION + 600 kΩ – LOW 500 kΩ – ...

Page 3

SMOKE DETECTOR with INTERCONNECT and TIMER ELECTRICAL CHARACTERISTICS 8.2 M (unless otherwise noted). 7 Characteristic Supply Voltage Range Detector Input Current Input Offset Voltage Hysteresis Common Mode Range Active Guard Impedance Oscillator Period Oscillator Pulse ...

Page 4

... No Alarm (No Smoke) Condition CIRCUIT DESCRIPTION The A5347CA is a low-current CMOS circuit providing all of the required features for an ionization-type smoke detector. Oscillator. An internal oscillator operates with a period of 1.67 seconds during no-smoke conditions. Every 1.67 seconds, internal power is applied to the entire circuit and a check is made for smoke. ...

Page 5

SMOKE DETECTOR with INTERCONNECT and TIMER Alarm Circuitry. If smoke is detected, the oscillator period changes and the horn is enabled. The horn output is typically 160 ms ON OFF. During the OFF time, ...

Page 6

SMOKE DETECTOR with INTERCONNECT and TIMER TIMING DIAGRAMS IN TYPICAL APPLICATION NO ALARM NO LOW BATTERY STANDBY MODE V12 OSC. CAP 1. INTERNAL CLOCK 24 CLOCK CYCLES LED LED OFF LED ON SMOKE COMPARATOR SAMPLE HORN ...

Page 7

SMOKE DETECTOR with INTERCONNECT and TIMER INTERNAL CLOCK HORN V2 IN I/O INTERNAL CLOCK HORN V2 OUT I/O I/O OPERATION REMOTE ALARM MODE CYCLES 2 CYCLES HORN OFF ON HORN NOT SELF COMPLETING WHEN IN REMOTE ...

Page 8

SMOKE DETECTOR with INTERCONNECT and TIMER 16 0.280 0.240 1 0.070 0.045 0.210 MAX 0.015 MIN 0.022 0.014 16 7.11 6.10 1 1.77 1.15 5.33 MAX 0.39 MIN 0.558 0.356 NOTES: 1. Lead thickness is measured at seating plane ...