LM89CIMM National Semiconductor, LM89CIMM Datasheet - Page 11

no-image

LM89CIMM

Manufacturer Part Number
LM89CIMM
Description
Manufacturer
National Semiconductor
Datasheet

Specifications of LM89CIMM

Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Output Type
Digital
Package Type
MSOP
Operating Temperature (min)
0C
Operating Temperature (max)
125C
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM89CIMM
Manufacturer:
NS
Quantity:
40
Part Number:
LM89CIMM
Manufacturer:
NS
Quantity:
5 321
Part Number:
LM89CIMM
Quantity:
61
Part Number:
LM89CIMM
Manufacturer:
NS
Quantity:
40
Part Number:
LM89CIMM
Manufacturer:
NSC
Quantity:
61
Part Number:
LM89CIMM
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM89CIMM
Quantity:
617
Company:
Part Number:
LM89CIMM
Quantity:
617
Part Number:
LM89CIMM/NOPB
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM89CIMMX
Manufacturer:
NS/国半
Quantity:
20 000
1.0 Functional Description
1.10 SERIAL INTERFACE RESET
In the event that the SMBus Master is RESET while the
LM89 is transmitting on the SMBData line, the LM89 must be
returned to a known state in the communication protocol.
This may be done in one of two ways:
1. When SMBData is LOW, the LM89 SMBus state ma-
chine resets to the SMBus idle state if either SMBData
or SMBCLK are held low for more than 35ms (t
Note that according to SMBus specification 2.0 all de-
vices are to timeout when either the SMBCLK or SMB-
Data lines are held low for 25-35ms. Therefore, to insure
(c) Serial Bus Read from a Register with the Internal Command Register preset to desired value.
(a) Serial Bus Write to the internal Command Register followed by a the Data Byte
(b) Serial Bus Write to the Internal Command Register
FIGURE 7. SMBus Timing Diagrams
(Continued)
TIMEOUT
LM89 Timing Diagram
).
11
1.9.1 SMBus Timing Diagrams
2. When SMBData is HIGH, have the master initiate an
1.11 DIGITAL FILTER
In order to suppress erroneous remote temperature readings
due to noise, the LM89 incorporates a user-configured digital
filter. The filter is accessed in the FILTER and ALERT CON-
a timeout of all devices on the bus the SMBCLK or
SMBData lines must be held low for at least 35ms.
SMBus start. The LM89 will respond properly to an
SMBus start condition at any point during the communi-
cation. After the start the LM89 will expect an SMBus
Address address byte.
20041510
20041511
20041512
www.national.com