AD7755AAN Analog Devices Inc, AD7755AAN Datasheet - Page 16

no-image

AD7755AAN

Manufacturer Part Number
AD7755AAN
Description
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7755AAN

Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Pin Count
24
Mounting
Through Hole
Package Type
PDIP
Screening Level
Industrial
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD7755AAN
Manufacturer:
AD
Quantity:
10
Part Number:
AD7755AAN
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
AD7755AAN
Quantity:
2 500
AD7755
S1
0
0
1
1
When selecting a suitable F
frequency output at I
stant of 100 imp/kWhr should be compared with Column 4 of
Table VI. The frequency that is closest in Table VI will deter-
mine the best choice of frequency (F
with a maximum current of 25 A is being designed, the out-
put frequency on F1 and F2 with a meter constant of 100 imp/
kWhr is 0.153 Hz at 25 A and 220 V (from Table V). Looking
at Table VI, the closest frequency to 0.153 Hz in column four is
0.17 Hz. Therefore F
design.
Frequency Outputs
Figure 1 shows a timing diagram for the various frequency out-
puts. The outputs F1 and F2 are the low frequency outputs that
can be used to directly drive a stepper motor or electromechani-
cal impulse counter. The F1 and F2 outputs provide two alter-
nating low going pulses. The pulsewidth (t
the time between the falling edges of F1 and F2 (t
mately half the period of F1 (t
and F2 falls below 550 ms (1.81 Hz) the pulsewidth of F1 and
F2 is set to half of their period. The maximum output frequen-
cies for F1 and F2 are shown in Table III.
0.200 (5.05)
0.125 (3.18)
Table VI. F1 and F2 Frequency with Half-Scale AC Inputs
(5.33)
0.210
MAX
PIN 1
S0
0
1
0
1
0.022 (0.558)
0.014 (0.356)
24
1
F
1.7
3.4
6.8
13.6
1–4
1.275 (32.30)
1.125 (28.60)
(2.54)
0.100
BSC
MAX
2
24-Lead Plastic DIP
(3.4 Hz—see Table II) is selected for this
Frequency on F1 and F2–
CH1 and CH2 Half-Scale AC Inputs
0.085 Hz
0.17 Hz
0.34 Hz
0.68 Hz
(maximum load) with a meter con-
0.070 (1.77)
0.045 (1.15)
1–4
(N-24)
frequency for a meter design, the
2
13
12
). If however the period of F1
0.280 (7.11)
0.240 (6.10)
0.060 (1.52)
0.015 (0.38)
SEATING
PLANE
1–4
). For example, if a meter
1
0.150
(3.81)
MIN
) is set at 275 ms and
0.325 (8.25)
0.300 (7.62)
0.015 (0.381)
0.008 (0.204)
3
Dimensions shown in inches and (mm).
) is approxi-
OUTLINE DIMENSIONS
0.195 (4.95)
0.115 (2.93)
0.301 (7.64)
0.311 (7.9)
0.078 (1.98)
0.068 (1.73)
0.008 (0.203)
0.002 (0.050)
The high frequency CF output is intended to be used for com-
munications and calibration purposes. CF produces a 90 ms-
wide active high pulse (t
power. The CF output frequencies are given in Table IV. As in
the case of F1 and F2, if the period of CF (t
the CF pulsewidth is set to half the period. For example, if the CF
frequency is 20 Hz, the CF pulsewidth is 25 ms.
NOTE: When the high frequency mode is selected, (i.e., SCF =
0, S1 = S0 = 1) the CF pulsewidth is fixed at 18 s. Therefore t
will always be 18 s, regardless of output frequency on CF.
NO LOAD THRESHOLD
The AD7755 also includes a “no load threshold” and “start-up
current” feature that will eliminate any creep effects in the
meter. The AD7755 is designed to issue a minimum output
frequency on all modes except when SCF = 0 and S1 = S0 = 1.
The no-load detection threshold is disabled on this output mode
to accommodate specialized application of the AD7755. Any
load generating a frequency lower than this minimum frequency
will not cause a pulse to be issued on F1, F2 or CF. The mini-
mum output frequency is given as 0.0014% of the full-scale
output frequency for each of the F
Table II. For example, an energy meter with a meter constant
of 100 imp/kWhr on F1, F2 using F
output frequency at F1 or F2 would be 0.0014% of 3.4 Hz or
4.76 10
In this example the no-load threshold would be equivalent to
1.7 W of load or a start-up current of 8 mA at 220 V. Compar-
ing this value to the IEC1036 specification which states that the
meter must start up with a load equal to or less than 0.4% Ib.
For a 5A (Ib) meter 0.4% of Ib is equivalent to 20 mA.
24
1
PIN 1
–5
0.0256
(0.65)
BSC
Hz. This would be 3.05 10
24-Lead Shrink Small Outline Package
0.328 (8.33)
0.318 (8.08)
0.015 (0.38)
0.010 (0.25)
4
) at a frequency proportional to active
SEATING
0.066 (1.67)
PLANE
0.07 (1.78)
13
12
(RS-24)
0.205 (5.207)
0.212 (5.38)
1–4
0.009 (0.229)
0.005 (0.127)
2
frequency selections—see
(3.4 Hz), the maximum
–3
Hz at CF (64 F1 Hz).
5
) falls below 180 ms,
0.022 (0.559)
0.037 (0.94)
4

Related parts for AD7755AAN