G5V-2-FDDC12

Manufacturer Part Number
G5V-2-FDDC12
Description
RELAY PC MNT DPDT
Manufacturer
Omron
Series
G5V-2r
Datasheet

Specifications of G5V-2-FDDC12

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
2A
Switching Voltage
125VAC, 125VDC - Max
Coil Type
Non Latching
Coil Current
41.7mA
Coil Voltage
12VDC
Turn On Voltage (max)
9 VDC
Turn Off Voltage (min)
0.6 VDC
Features
Sealed - Fully
Mounting Type
Through Hole
Termination Style
PC Pin
Contact Material
Silver (Ag), Gold (Au)
Operate Time
7ms
Release Time
3ms
Coil Power
500 mW
Coil Resistance
288 Ohms
Operating Temperature
-25°C ~ 65°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G5V2FDDC12
■ Coil Data
Standard Type
High-sensitivity Type
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
Characteristics
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
78
3
5
6
9
12
24
48
3
5
6
9
12
24
48
Contact resistance (See note 1)
Operate time (See note 2)
Release time (See note 2)
Operating frequency
(max.)
Insulation resistance (See note 3)
Dielectric strength
Surge withstand voltage
Vibration
Shock
Ambient temperature
Humidity
Service life
Weight
Rated voltage
Rated voltage
(VDC)
(VDC)
2. The operating characteristics are measured at a coil temperature of 23°C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
2. Values in parentheses are typical values unless otherwise stated.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength.
4. The above values are initial values.
Low Signal Relay
Rated current
166.70
100
83.30
55.60
41.70
20.80
12
Rated current
50
30
25
16.70
12.50
8.33
6.25
(mA)
(mA)
Mechanical
Electrical
Mechanical durability 10 to 55 Hz, 1.50 mm double amplitude
Malfunction
durability
Mechanical durability 1,000 m/s
Malfunction
durability
Operating/storage
Mechanical
Electrical
18
50
72
162
288
1,152
4,000
60
166.7
240
540
960
2,880
7,680
resistance
resistance
Coil
Coil
(Ω)
(Ω)
G5V-2
Armature OFF Armature ON
0.04
0.09
0.16
0.31
0.47
1.98
7.23
Armature OFF Armature ON
0.18
0.46
0.70
1.67
2.90
6.72
20.10
50 mΩ max. (G5V-2); 100 mΩ max. (G5V-2-H1)
7 ms max. (mean value: approx. 3.5 ms)
3 ms max. (mean value: approx. 0.8 ms)
36,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min (at 500 VDC)
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles
750 VAC, 50/60 Hz for 1 minute between contacts of same poles
(500 VAC, 50/60 Hz for 1 minute between contacts of same poles for high-sensitive type)
1,500 V (10 X 160 μs) between coil and contacts (conforms to part 68 of FCC rules)
200 m/s
-25° to 70°C (“-H1” versions) with no icing
-25° to 65°C (standard versions) with no icing
5% to 85% RH
15 million operations min. (at operating frequency of 36,000 operations/hour)
100,000 operations min. (at 1,800 operations/hr). See “Characteristic Data”
Approx. 5 g
Coil inductance
Coil inductance
(Ref. value) (H)
(Ref. value) (H)
2
0.05
0.11
0.19
0.49
0.74
2.63
10.00
0.57
0.71
0.97
2.33
3.99
9.27
26.70
(approx. 20 G), 100 m/s
2
(approx. 100 G)
75% max.
75% max.
Pick-up
voltage
Pick-up
voltage
2
(approx. 10 G) for high-sensitive type
% of rated voltage
% of rated voltage
5% min.
5% min.
Dropout
Dropout
voltage
voltage
120% max.
at 23°C
180% max.
at 23°C
150% max.
at 23°C
Maximum
Maximum
voltage
voltage
Approx. 500
Approx. 580
Approx. 150
Approx. 200
Approx. 300
consumption
consumption
Power
Power
(mW)
(mW)