Specifications of ADT7461AARMZ-2

Temperature Sensor Function
Temp Sensor
Interface Type
Serial (2-Wire)
Output Type
Digital
Package Type
MSOP
Operating Temperature (min)
-40C
Operating Temperature (max)
125C
Operating Temperature Classification
Automotive
Operating Supply Voltage (min)
3V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / Rohs Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADT7461AARMZ-2
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADT7461AARMZ-2RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
1. Guaranteed by design, but not production tested.
2. Time from 10% of SDATA to 90% of SCLK.
3. Time for 10% or 90% of SDATA to 10% of SCLK.
4. Time for 90% of SCLK to 10% of SDATA.
PIN ASSIGNMENT
SMBus TIMING SPECIFICATIONS
Pin No.
t
t
t
HD; STA
SU; DAT
SU; STO
1
2
3
4
5
6
7
8
Parameter
SDATA
t
SCLK
SU; STA
f
t
t
SCLK
t
HIGH
LOW
BUF
t
t
R
F
(Note 2)
(Note 3)
(Note 4)
ALERT/THERM2
STOP START
Mnemonic
t
THERM
BUF
SDATA
SCLK
GND
V
D+
D−
DD
Limit at T
t
t
LOW
HD;STA
MIN
400
300
300
600
600
100
600
1.3
0.6
1.3
Positive Supply, 3.0 V to 3.6 V.
Positive Connection to Remote Temperature Sensor.
Negative Connection to Remote Temperature Sensor.
Open−Drain Output. Can be used to turn a fan on/off or throttle a CPU clock in the event of an
overtemperature condition. Requires pullup resistor.
Supply Ground Connection.
Open−Drain Logic Output Used as Interrupt or SMBus ALERT. This can also be configured as a
second THERM output. Requires pullup resistor.
Logic Input/Output, SMBus Serial Data. Open−Drain Output. Requires pullup resistor.
Logic Input, SMBus Serial Clock. Requires pullup resistor.
t
HD;DAT
and T
(Note 1)
t
R
MAX
Figure 2. Serial Bus Timing
t
F
t
HIGH
kHz max
http://onsemi.com
ns max
ns max
t
ms min
ms min
ns min
ns min
ns min
ns min
ms min
SU;DAT
Unit
3
Clock low period, between 10% points.
Clock high period, between 90% points.
Clock/data rise time.
Clock/data fall time.
Start condition setup time.
Start condition hold time.
Data setup time.
Stop condition setup time.
Bus free time between stop and start conditions.
Description
START
t
SU;STA
t
HD;STA
Description
t
SU;STO
STOP