5962-8606310XA STMicroelectronics, 5962-8606310XA Datasheet - Page 14

no-image

5962-8606310XA

Manufacturer Part Number
5962-8606310XA
Description
Manufacturer
STMicroelectronics
Datasheet

Specifications of 5962-8606310XA

Lead Free Status / Rohs Status
Supplier Unconfirmed

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
5962-8606310XA
Quantity:
473
DSCC FORM 2234
APR 97
or approved alternatives shall be as specified in the device manufacturer's QM plan in accordance with MIL-PRF-38535. The
test circuit shall be maintained under document revision level control by the device manufacturer's TRB in accordance with
MIL-PRF-38535 and shall be made available to the acquiring or preparing activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in method 1005 of MIL-STD-
883.
(see 3.5 herein).
has a wavelength of 2537 Angstroms (Å). The integrated` dose (i.e., UV intensity x exposure time) for erasure should be a
minimum of 15 Ws/cm 2 . The erasure time with this dosage is approximately 15 to 20 minutes using an ultraviolet lamp with a
12000 µW/cm 2 power rating. The device should be placed within 1 inch of the lamp tubes during erasure. The maximum
integrated dose the device can be exposed to without damage is 7258 Ws/cm 2 (1 week at 12000 µW/cm 2 ). Exposure of
EPROMS to high intensity UV light for long periods may cause permanent damage.
made available upon request.
before and after the required burn-in screens and steady-state life tests to determine delta compliance. The electrical
parameters to be measured, with associated delta limits are listed in table IIB. The device manufacturer may, at his option,
either perform delta measurements or within 24 hours after burn-in perform final electrical parameter tests, subgroups 1, 7,
and 9.
Q and V or MIL-PRF-38535, appendix A for device class M.
4.4.2 Group C inspection. The group C inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.2.1 Additional criteria for device class M. Steady-state life test conditions, method 1005 of MIL-STD-883:
4.4.2.2 Additional criteria for device classes Q and V. The steady-state life test duration, test condition and test temperature,
4.4.3 Group D inspection. The group D inspection end-point electrical parameters shall be as specified in table IIA herein.
4.4.4 Group E inspection. Group E inspection is required only for parts intended to be marked as radiation hardness assured
4.5 Erasing procedure. The recommended erasure procedure for the device is exposure to shortwave ultraviolet light which
4.6 Programming procedure. The programming procedures shall be as specified by the device manufacturer and shall be
4.7 Delta measurements for device class V. Delta measurements, as specified in table IIA, shall be made and recorded
5. PACKAGING
5.1 Packaging requirements. The requirements for packaging shall be in accordance with MIL-PRF-38535 for device classes
a.
b.
c.
d.
a.
b.
Test condition A, C, or D. The test circuit shall be maintained by the manufacturer under document revision level
T
Test duration: 1,000 hours, except as permitted by method 1005 of MIL-STD-883.
All devices selected for testing shall be programmed with a checkerboard pattern or equivalent. After completion of all
End-point electrical parameters shall be as specified in table IIA herein.
For device classes Q and V, the devices or test vehicle shall be subjected to radiation hardness assured tests as
specified in MIL-PRF-38535 for the RHA level being tested. For device class M, the devices shall be subjected to
radiation hardness assured tests as specified in MIL-PRF-38535, appendix A for the RHA level being tested. All device
classes must meet the postirradiation end-point electrical parameter limits as defined in table I at
T
DEFENSE SUPPLY CENTER COLUMBUS
control and shall be made available to the preparing or acquiring activity upon request. The test circuit shall specify the
inputs, outputs, biases, and power dissipation, as applicable, in accordance with the intent specified in test method
1005 of MIL-STD-883.
testing, the devices shall be erased and verified.
A
A
= +125°C, minimum.
= +25°C ± 5°C, after exposure, to the subgroups specified in table IIA herein.
MICROCIRCUIT DRAWING
COLUMBUS, OHIO 43218-3990
STANDARD
SIZE
A
REVISION LEVEL
H
SHEET
5962-86063
14