LY2ZF-AC24 Omron, LY2ZF-AC24 Datasheet - Page 5

no-image

LY2ZF-AC24

Manufacturer Part Number
LY2ZF-AC24
Description
RELAY PWR DPDT 5A 24VAC
Manufacturer
Omron
Series
LYr
Datasheet

Specifications of LY2ZF-AC24

Relay Type
General Purpose
Contact Form
DPDT (2 Form C)
Contact Rating (current)
5A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Non Latching
Coil Current
46mA
Coil Voltage
24VAC
Turn On Voltage (max)
19.2 VAC
Turn Off Voltage (min)
7.2 VAC
Features
-
Mounting Type
Chassis Mount
Termination Style
Plug In
Contact Material
Silver Alloy
Operate Time
25ms
Release Time
25ms
Coil Power
1.2 VA
Coil Resistance
180 Ohms
Operating Temperature
-25°C ~ 55°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
LY2ZFAC24
■ Characteristics
Note: Data shown are of initial value.
■ Characteristic Data
Maximum switching capacity
LY1
Electrical service life
LY1
Contact resistance
Operate time
Release time
Operating frequency
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Humidity
Service Life
Weight
Rated operating voltage (V)
Switching current (A)
Mechanically
Under rated load
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Mechanically
Electrically
LY2
LY2
Rated operating voltage (V)
Switching current (A)
50 mΩ max.
25 ms max.
25 ms max.
18,000 operations/hour
1,800 operations/hour
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 minute
1,000 VAC, 50/60 Hz for 1 minute between contacts of same polarity
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
10 to 55 Hz, 1.00 mm (0.04 in) double amplitude
1,000 m/s
200 m/s
LY1, LY2, LY3: -25° to 55°C; LY4 =-25° to 40°C
35 to 85% RH
AC: 50 million operations min. (at operating frequency of 18,000 operations/hour)
DC: 100 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
SPDT, DPDT: Approx. 40 g (1.41 oz), 3PDT: Approx. 50 g (1.76 oz)
4PDT: Approx. 70 g (2.47 oz)
2
(approx. 20 G)
2
(approx. 100 G)
LY3, LY4
LY3, LY4
Rated operating voltage (V)
Switching current (A)
General Purpose Relay
LY2Z
LY2Z
Rated operating voltage (V)
Switching current (A)
LY
289