MY4-DC6-EL Omron, MY4-DC6-EL Datasheet - Page 2

no-image

MY4-DC6-EL

Manufacturer Part Number
MY4-DC6-EL
Description
RELAY GP 4PDT 6VDC
Manufacturer
Omron
Series
MYr
Datasheet

Specifications of MY4-DC6-EL

Relay Type
General Purpose
Contact Form
4PDT (4 Form C)
Contact Rating (current)
3A
Switching Voltage
250VAC, 125VDC - Max
Coil Type
Non Latching
Coil Current
151mA
Coil Voltage
6VDC
Turn On Voltage (max)
4.8 VDC
Turn Off Voltage (min)
0.6 VDC
Features
-
Mounting Type
Socketable
Termination Style
Plug In
Contact Material
Silver (Ag)
Operate Time
20ms
Release Time
20ms
Coil Power
900 mW
Coil Resistance
39.8 Ohms
Operating Temperature
-55°C ~ 70°C
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
MY4DC6EL
Specifications
■ Coil Ratings
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with tolerances of +15%/–20% for rated currents and
■ Contact Ratings
Note: Do not exceed the carry current of a Socket in use.
260
Rated voltage
AC
DC
Item
Rated load
Carry current
Max. switching
voltage
Max. switching
current
Max. switching
capacity
Min.
permissible
load*
* Reference value.
2. Performance characteristic data are measured at a coil temperature of 23°C.
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder re-
5. Rated voltage denoted by “*” will be manufactured upon request. Ask your OMRON representative.
6 V*
12 V
24 V
48/50 V*
110/120 V
220/240 V
6 V*
12 V
24 V
48 V*
100/110 V
±15% for DC coil resistance.
sistor if required.
General-purpose Relay
2-pole
Resistive load
(cosφ = 1)
5 A, 250 VAC
5 A, 30 VDC
10 A (see note)
250 VAC
125 VDC
10 A
2,500 VA
300 W
5 VDC, 1 mA
Rated current
50 Hz
214.1 mA
106.5 mA
53.8 mA
24.7/
25.7 mA
9.9/10.8 mA 8.4/9.2 mA
4.8/5.3 mA 4.2/4.6 mA
151 mA
75 mA
37.7 mA
18.8 mA
9.0/9.9 mA
60 Hz
183 mA
91 mA
46 mA
21.1/
22.0 mA
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
2 A, 250 VAC
2 A, 30 VDC
1,250 VA
300 W
MY
Coil
resistance
12.2 Ω
46 Ω
180 Ω
788 Ω
4,430 Ω
18,790 Ω
39.8 Ω
160 Ω
636 Ω
2,560 Ω
11,100 Ω
4-pole
Resistive load
(cosφ = 1)
3 A, 250 VAC
3 A, 30 VDC
5 A (see note)
250 VAC
125 VDC
5 A
1,250 VA
150 W
1 VDC, 1 mA
Inductance
(reference value)
Arm. OFF
0.04 H
0.17 H
0.69 H
3.22 H
19.20 H
83.50 H
0.17 H
0.73 H
3.20 H
10.60 H
45.60 H
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
0.8 A, 250 VAC
1.5 A, 30 VDC
500 VA
150 W
Arm. ON
0.08 H
0.33 H
1.30 H
5.66 H
32.1 H
136.4 H
0.33 H
1.37 H
5.72 H
21.0 H
86.2 H
Must
operate
% of rated voltage
80% max. 30% min. 110%
4-pole (bifurcated)
Resistive load
(cosφ = 1)
3 A, 250 VAC
3 A, 30 VDC
1,250 VA
150 W
1 VDC, 100 μA
Must
release
10% min.
Max.
voltage
Inductive load
(cosφ = 0.4,
L/R = 7 ms)
0.8 A, 250 VAC
1.5 A, 30 VDC
500 VA
150 W
Power
consumption
(approx.)
1.0 to 1.2 VA
(60 Hz)
0.9 to 1.1 VA
(60 Hz)
0.9 W

Related parts for MY4-DC6-EL