CC-92K2-IP5 Copeland Communications Inc, CC-92K2-IP5 Datasheet - Page 30

no-image

CC-92K2-IP5

Manufacturer Part Number
CC-92K2-IP5
Description
MODEM 56KBAUD V.90 PARALLEL 5V
Manufacturer
Copeland Communications Inc
Datasheet

Specifications of CC-92K2-IP5

Data Format
V.22, V23, V.32, V.34, V.90, V.92, Bell 103, Bell 212A
Baud Rates
56k
Interface
UART
Voltage - Supply
4.2 V ~ 7 V
Mounting Type
Surface Mount
Package / Case
Module
For Use With
539-1002 - KIT EVALUATION WORLD MODEM II
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Extended AT\ Command Set (Command Defaults in Bold) (Continued)
© 2004, Copeland Communications, Inc.
Notes:
1. When in autobaud mode, \B0, \B1, and \P1 will not be detected automatically. The combination of \B2 and \P3 will be
detected. This is compatible with 7N2. 7N1 may be forced by sending AT\T17\B1.
2. The autobaud feature does not detect this rate.
3. Default is \T16. \T9 may be defaulted as an order option. Contact the factory for details
Command
\T10
\T11
\T12
\T13
\T14
\T15
\T16
\T17
\Vn
\V0
\V2
\V4
\Tn
\T0
\T1
\T2
\T3
\T4
\T5
\T6
\T7
\T8
\T9
\U
DTE rate - Change DTE rate. When the modem is configured in autobaud mode (default), \T0
through \T15 will lock the new baud rate and disable autobaud.
300 bps
600 bps
1200 bps
2400 bps
4800 bps
7200 bps
9600 bps
12.0 kbps
14.4 kbps
19.2 kbps
38.4 kbps
57.6 kbps
115.2 kbps
230.4 kbps
245.760 kbps
307.200 kbps
Autobaud on
Autobaud off; locked at current baud rate.
Causes a low pulse (25 ms) on RI and DCD. INT to be the inverse of ESC. RTS to be inverse of
CTS. This command terminates with a RESET.
Connect message type.
Report connect message and protocol message.
Report connect message only (exclude protocol message).
Report connect and protocol message with both upstream nad downstream connect rates.
2
3
2
3
Page 30 of 60
Data Sheet
Action
World modem II Datasheet Rev 1.1
World modem II

Related parts for CC-92K2-IP5