SI2457-C-FT Silicon Laboratories Inc, SI2457-C-FT Datasheet - Page 27

no-image

SI2457-C-FT

Manufacturer Part Number
SI2457-C-FT
Description
IC ISOMODEM SYSTEM-SIDE 24TSSOP
Manufacturer
Silicon Laboratories Inc
Datasheets

Specifications of SI2457-C-FT

Package / Case
24-TSSOP
Mfg Application Notes
SI2493/57/34/15/04, Appl Note AN93
Data Format
V.21, V.22, V.23, V.32, V.34, V.90, Bell 103, Bell 212A
Baud Rates
56k
Interface
Parallel, UART
Voltage - Supply
3 V ~ 3.6 V
Mounting Type
Surface Mount
Operating Frequency
4.92 MHz
Supply Voltage (max)
3.6 V
Supply Voltage (min)
3 V
Supply Current
26 mA
Operating Temperature Range
0 C to + 70 C
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SI2457-C-FT
Manufacturer:
Silicon Labs
Quantity:
135
Part Number:
SI2457-C-FT
Manufacturer:
MURATA
Quantity:
10 122
Part Number:
SI2457-C-FTR
Manufacturer:
SILTCON
Quantity:
20 000
+IFC Options
+IFC = A
+IFC = A,B
+ITF Options
+ITF = A
+ITF = A,B
+ITF = A,B,C
+MR = X
+MS Options
+MS = A
+MS = A,B
+MS = A,B,C
+MS = A,B,C,D
+MS = A,B,C,D,E
+MS = A,B,C,D,E,F
Command
Table 10. Basic AT Command Set (Command Defaults in Bold) (Continued)
Specifies the flow control to be implemented.
A
B
Transmit flow control threshold.
A
B
C
Modulation reporting control.
X
0
1
If enabled, the intermediate result code is transmitted at the point during connect negotiation.
The format of this result code is as follows:
+MCR: <carrier> e.g. +MCR: V32B
+MRR: <rate>
Modulation Selection.
A
B
C,D
E,F
Specifies the flow control method used by the modem to control data from the host
Specifies the flow control method used by the host to control data from the modem
0 None
1 Local XON/OFF flow control.
2 Hardware flow control (CTS).
Threshold above which the modem will generate a flow off signal
<0 to 511> bytes
Threshold below which the modem will generate a flow on signal
<0 to 511> bytes
Polling interval for <EM><BNUM> indicator
0 to 300 in 10 msec units.
2 Hardware flow control (RTS)
0 None
1 Local XON/OFF flow control. Does not pass XON/XOFF character to the remote
Disabled
Enabled
Mode
V21
V22
V22B
V32
V32B
V34
V90
modem.
0
1
Preferred modem carrier
Automatic modulation negotiation
Min TX rate/Max TX rate are optional numeric values that specify the lowest value
Min RX rate/Max RX rate are optional numeric values which specify the highest
at which the DCE may establish a connection. If unspecified (set to 0), they are
determined by the carrier and automode settings.
value at which the DCE may establish a connection. If unspecified (set to 0), they
are determined by the carrier and automode settings.
ITU-T V.21
ITU-T V.22
ITU-T V.32
ITU-T V.34 (default for Si2434)
ITU-T V.90 (default for Si2457)
ITU-T V.22bis (default for Si2404)
ITU-T V.32bis (default for Si2415)
Disabled
Enabled
e.g. +MRR: 14400
Rev. 1.1
Action
Si2457/34/15/04
27

Related parts for SI2457-C-FT