VS-30CTQ080-1PBF Vishay, VS-30CTQ080-1PBF Datasheet - Page 2

Schottky (Diodes & Rectifiers) 30 Amp 80 Volt Common Cathode

VS-30CTQ080-1PBF

Manufacturer Part Number
VS-30CTQ080-1PBF
Description
Schottky (Diodes & Rectifiers) 30 Amp 80 Volt Common Cathode
Manufacturer
Vishay
Datasheet

Specifications of VS-30CTQ080-1PBF

Product
Schottky Rectifiers
Peak Reverse Voltage
80 V
Forward Continuous Current
30 A
Max Surge Current
850 A
Configuration
Dual Common Cathode
Forward Voltage Drop
1.05 V
Maximum Reverse Leakage Current
2000 uA
Operating Temperature Range
- 55 C to + 175 C
Mounting Style
Through Hole
Package / Case
TO-262
Lead Free Status / Rohs Status
 Details
Document Number: 94193
Bulletin PD-21035 rev. A 07/06
30CTQ...SPbF, 30CTQ...-1PbF Series
Voltage Ratings
Absolute Maximum Ratings
Thermal-Mechanical Specifications
Electrical Specifications
I
I
E
I
V
I
C
L
dv/dt Max. Voltage Rate of Change
T
T
R
R
R
wt
T
V
V
FSM
F(AV)
AR
RM
S
AS
FM
J
stg
thJC
thJC
thCS
R
RWM
T
to Heatsink
Parameters
Max. Average Forward
Current
Max. Peak One Cycle Non-Repetitive
Surge Current (Per Leg)
Non-Repetitive Avalanche Energy
(Per Leg)
Repetitive Avalanche Current
(Per Leg)
Max. Forward Voltage Drop
(Per Leg) * See Fig. 1
Max. Reverse Leakage Current
(Per Leg) * See Fig. 2
Max. Junction Capacitance (Per Leg)
Typical Series Inductance (Per Leg)
Max. Junction Temperature Range
Max. Storage Temperature Range
Max. Thermal Resistance Junction
to Case (Per Leg)
Max. Thermal Resistance Junction
to Case (Per Package)
Typical Thermal Resistance, Case
Approximate Weight
Mounting Torque
Marking Device
Parameters
Max. DC Reverse Voltage (V)
Max. Working Peak Reverse Voltage (V)
Parameters
Parameters
* See Fig. 5
(Per Leg)
(Per Device)
* See Fig. 7
(1)
(1)
Min.
Max.
-55 to 175
-55 to 175
Values Units
Values Units
Values Units
2 (0.07)
12 (10)
10000
7.50
0.50
0.86
1.05
0.67
0.82
0.55
3.25
1.63
0.50
6 (5)
850
275
500
7.0
8.0
15
30
30CTQ...S
30CTQ...-1
Kg-cm
(Ibf-in)
g (oz.)
°C/W
°C/W
°C/W
V/ μs (Rated V
mA
mA
mJ
nH
pF
°C
°C
A
A
A
V
V
V
V
50% duty cycle @ T
Frequency limited by T
5μs Sine or 3μs Rect. pulse
10ms Sine or 6ms Rect. pulse
T
Current decaying linearly to zero in 1 μsec
@ 15A
@ 30A
@ 15A
@ 30A
T
T
V
Measured lead to lead 5mm from package body
Case style TO-262
DC operation
DC operation
Mounting surface , smooth and greased
(only for TO-220)
Case style D
30CTQ080-1
J
30CTQ080S
J
J
R
= 25 °C, I
= 25 °C
= 125 °C
= 5V
80
DC
R
)
(test signal range 100Khz to 1Mhz) 25°C
Conditions
Conditions
Conditions
AS
2
Pak
= 0.50 Amps, L = 60 mH
(1) Pulse Width < 300μs, Duty Cycle <2%
V
T
T
J
J
R
= 25 °C
= 125 °C
= rated V
C
= 129°C, rectangular wave form
J
max. V
R
Following any rated
load condition and with
rated V
A
= 1.5 x V
30CTQ100-1
30CTQ100S
www.vishay.com
100
RRM
R
typical
applied
2

Related parts for VS-30CTQ080-1PBF