KSZ8041RNL Micrel Inc, KSZ8041RNL Datasheet - Page 38

TXRX 10/100 3.3V PHY RMII 32-MLF

KSZ8041RNL

Manufacturer Part Number
KSZ8041RNL
Description
TXRX 10/100 3.3V PHY RMII 32-MLF
Manufacturer
Micrel Inc
Type
Transceiverr
Datasheets

Specifications of KSZ8041RNL

Number Of Drivers/receivers
1/1
Protocol
RMII
Voltage - Supply
3.135 V ~ 3.465 V
Mounting Type
Surface Mount
Package / Case
32-MLF®, QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
576-3503

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
KSZ8041RNL
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
Part Number:
KSZ8041RNL TR
Manufacturer:
Micrel
Quantity:
1 276
Part Number:
KSZ8041RNL-TR
Manufacturer:
MICROCHIP
Quantity:
200
Part Number:
KSZ8041RNL-TR
Manufacturer:
MICROCHIP
Quantity:
310
Part Number:
KSZ8041RNL-TR
0
Part Number:
KSZ8041RNLI TR
Manufacturer:
Micrel
Quantity:
918
Part Number:
KSZ8041RNLI-TR
0
Company:
Part Number:
KSZ8041RNLI-TR
Quantity:
1 000
Part Number:
KSZ8041RNLTR
Manufacturer:
NEC
Quantity:
327
Part Number:
KSZ8041RNLTR
Manufacturer:
MICREL/麦瑞
Quantity:
20 000
Part Number:
KSZ8041RNLU TR
Manufacturer:
Micrel
Quantity:
955
Micrel, Inc.
Register Description (Continued)
September 2010
Address
Register 1Eh – PHY Control 1
1e:15:14
1e.13
1e.12
1e.11
1e:10:8
1e:7
1e:6:0
Register 1Fh – PHY Control 2
1f:15
1f:14
1f:13
1f.12
1f.11
Name
LED mode
Polarity
Reserved
MDI/MDI-X
State
Reserved
Remote
loopback
Reserved
HP_MDIX
MDI/MDI-X
Select
Pairswap
Disable
Energy Detect
Force Link
Description
[00] =
[01] =
[10], [11] = Reserved
0 = Polarity is not reversed
1 = Polarity is reversed
0 = MDI
1 = MDI-X
0 = Normal mode
1 = Remote (analog) loop back is enable
0 = Micrel Auto MDI/MDI-X mode
1 = HP Auto MDI/MDI-X mode
When Auto MDI/MDI-X is disabled,
0 = MDI Mode
1 = MDI-X Mode
1 = Disable auto MDI/MDI-X
0 = Enable auto MDI/MDI-X
1 = Presence of signal on RX+/- analog wire
0 = No signal detected on RX+/-
1 = Force link pass
0 = Normal link operation
This bit bypasses the control logic and allow
transmitter to send pattern even if there is no
link.
Transmit on RX+/- (pins 5,4) and
Receive on TX+/- (pins 7,6)
pair
Transmit on TX+/- (pins 7,6) and
Receive on RX+/- (pins 5,4)
LED1 : Speed
LED0 : Link/Activity
LED1 : Activity
LED0 : Link
38
Mode
RW
RO
RO
RO
RW
RW
RW
RW
RO
RW
(1)
Default
00
0
0
1
0
0
0
0
M9999-090910-1.4
KSZ8041NL/RNL

Related parts for KSZ8041RNL