E5ENR3HMT500NAC100240 Omron Automation, E5ENR3HMT500NAC100240 Datasheet

no-image

E5ENR3HMT500NAC100240

Manufacturer Part Number
E5ENR3HMT500NAC100240
Description
Temperature Controller, Digital, 1/8 Din, Relay Output, Heater Burnout Alarm
Manufacturer
Omron Automation
Type
Temperaturer
Datasheet

Specifications of E5ENR3HMT500NAC100240

Brand/series
E5EN Series
Contact Form
SPST-NO
Dimensions
46mmW×96mmH×78mmD
Enclosure Rating
IP00, IP20, IP66
Ip Rating
IP00, IP20, IP66
Mounting Type
DIN Rail
Number Of Outputs
3
Output Type
Relay
Primary Type
Controller
Standards
UL, CSA
Voltage, Supply
100 to 240 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with
Enhanced Functions and Performance.
Improved Indication Accuracy and
Preventive Maintenance Function.
Main I/O Functions
• Indication Accuracy
• A PV/SV-status display function can be set to automatically
• Preventive maintenance for relays in the Temperature Controller
• Three-level display that simultaneously displays the PV, SV, and
• One-touch operation with PF Key that can be assigned to auto/
Basic-type Digital Temperature Controller
E5AN/E5EN
Thermocouple input: ±0.3% of PV (previous models: ±0.5%)
Pt input: ±0.2% of PV (previous models: ±0.5%)
Analog input: ±0.2% FS (previous models: ±0.5%)
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or
SV.
using a Control Output ON/OFF Counter.
MV.
manual, RUN/STOP, or other functions.
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)
Sensor Inputs
• Universal thermocouple/Pt inputs
• Analog current/voltage inputs
Indication Accuracy
• Thermocouple input: ±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% FS
Sampling Period
• 250 ms
(Models with temperature inputs)
(Models with analog inputs)
PF Key
(Programmable function key)
Event Inputs
• None
• Two
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Current output
E5AN
Control Output 2
• Voltage output
• Long-life relay
output (hybrid)
(for driving SSR)
(96 x 96 mm and 48 x 96 mm)
E5EN
Auxiliary Outputs
• Three
96 × 96 mm
Refer to Safety Precautions for E5
4-digit Display
E5AN
3-level Display *
Simultaneously displays set items,
such as the PV, SV, and MV.
* A 2-level display when shipped from the factory. A
3-level display is activated if parameters are
initialized. For details on the third display level, refer
to the User’s Manual, Basic Type (Cat. No. H156).
• Auto/manual switching
• Temperature Controller
• Simple program function
• Control output ON/OFF
• PV change rate alarm
• Models also available with
status display
count alarm
RS-485 or RS-232C
communications
CSM_E5AN_E5EN_DS_E_2_1
48 × 96 mm
@
E5EN
N/E5
@
N-H.
1

Related parts for E5ENR3HMT500NAC100240

E5ENR3HMT500NAC100240 Summary of contents

Page 1

Basic-type Digital Temperature Controller E5AN/E5EN New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. • Indication Accuracy Thermocouple input: ±0. (previous models: ±0.5%) Pt ...

Page 2

Lineup E5AN/E5EN Terminal block Basic Type Note: Models with one control output or two control outputs can be used for heating/cooling control. Model Number Structure Model Number Legend Controllers E5AN/E5EN-@3@M@@-@-500 Control Output ...

Page 3

Ordering Information E5AN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/4 DIN 96 × 96 × 78 Analog (W × H × D) (current/voltage) Thermocouple 24 ...

Page 4

E5EN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/8 DIN 48 × 96 × × H × D) Analog (current/voltage) Thermocouple 24 VAC/ or ...

Page 5

Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power 100 to 240 ...

Page 6

Characteristics Thermocouple: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max. Indication accuracy Analog input: ±0.2% FS ±1 digit max. CT ...

Page 7

E5EN 48 96 Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 USB connector (type A plug) Terminal Covers E53-COV16 (Six Covers provided.) 6 79.2 2 112 91 Terminal Cover (E53-COV16) Waterproof Mounting Bracket (Accessory) Packing (Accessory) (Accessory) Crimp terminal size: M3.5 ...