G9SA-321-T30-AC100240 Sti (Scientific Technologies, Inc.), G9SA-321-T30-AC100240 Datasheet - Page 9

no-image

G9SA-321-T30-AC100240

Manufacturer Part Number
G9SA-321-T30-AC100240
Description
Relay, Safety Monitoring, 100-240VAC, 3NO Immediate, 2NO Delayed, 30sec
Manufacturer
Sti (Scientific Technologies, Inc.)
Datasheet

Specifications of G9SA-321-T30-AC100240

Brand/series
G9SA Series
Lead Free Status / Rohs Status
RoHS Compliant part
G9SA-TH301 (24 VDC) with 2-hand Inputs/Auto-reset
D-56
(See note 1.)
Control circuit
Feedback loop
Timing Chart
S11 (NC)
S11 (NO)
S12 (NC)
S12 (NO)
KM1 and KM2
(NC)
KM1 and KM2
(NO)
S11, S12:
KM1 and KM2: Magnetic Contactor
Note: 1. Use a 1NC+1NO switch for S11
Safety Sensors / Components
Input time difference operates only
when the difference is 0.5 s max.
2. This circuit achieves EN954-1
and S12.
Safety Category 4.
Typ III C (EN 574)
Two-hand pushbutton switches
0.5 s max.