DNC-T2101-B10 NCC, DNC-T2101-B10 Datasheet

no-image

DNC-T2101-B10

Manufacturer Part Number
DNC-T2101-B10
Description
Dust Collector; Inetermittent shaker control, 120 delay, 105 to 135 VAC
Manufacturer
NCC
Datasheet
AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com
4-2
FEATURES
LOGIC FUNCTION DIAGRAM
Fan
Switch
Operating Logic: The control is used on
intermittent type dust collectors to auto-
matically activate the shaking mechanism 2
minutes after the fan motor is turned off.
minute fixed delay is initiated. At the end
of the delay, the shaker output is activated
for an adjustable period of 1.8 seconds to
3 minutes. Resetting the control occurs by
turning the fan motor on again.
CAUTION: The control must be wired according to the schematic
provided.
ORDERING INFORMATION
AMETEK NCC offers NEMA 4 type enclosures for mounting our controls. These enclosures are made of heavy gauge steel and have a con-
tinuous hinge cover. All seams are continuously welded. The finish is gray hammer-tone enamel inside and out, over phosphatized surfaces.
Intermittent Use Collectors
Model T2101
Shaker
Load
Control on Chassis
Control in Hinged NEMA 4 Box with Functional Lights
NEMA 4 Box
Pilot Lamp
On/Off Switch
Upon removing power from the fan, a 2
Simple 4 wire installation
Replaces electromechanical timers
Completely solid state timing and
switching logic
High quality locking bushing
potentiometers for timing adjustment
Very low power consumption
Conformally coated for protection
against vibration, humidity, and con-
tamination
LED function lights on PC board
Function indicating lights on T2101-020
Mounts in standard NEMA 4/JIC
enclosures
On
Off
On
Off
ACCESSORY
DUST COLLECTOR CONTROLS
File #E65038
2 minutes
fixed
DESCRIPTION
1.8 sec.- 3 min
adjust
NEMA 4 Rated with Legend Plate
NEMA 4 Rated Red Light
DIMENSIONS
6” x 8” x 4”
New
cycle
SPECIFICATIONS
TIMING
Delay Time: 120 sec. ±10% fixed
Shake Time: Adjustable from 1.8 to 180 sec.
Repeatability: ±3% over temperature and volt-
age range
INPUT
Operating Voltage: 105 to 135 VAC
Power Consumption: 5.5 W plus shaker contac-
tor coil power
Frequency: 50/60 Hz
OUTPUT
Type: Solid state switch, 1 A continuous at 1.5 V
below input voltage
TRANSIENT PROTECTION
Input: Transformer and large filter capacity
Output: Solid state switch rated for 10 A at 400V
protected by metal oxide varistor; 3 A fuse pro-
tects against external short circuit
ENVIRONMENTAL
Operating Temperature: -40°C to 65°C
Storage Temperature: -40°C to 70°C
PART NUMBER
DNC-T2101-010
DNC-T2101-020
ASL-00RED-NEMA 4
BOX-A0606-CHNF
MSW-0DPST-011
PART NUMBER
Caution:
1. Do not mount controls in high vibration areas with-
out shock mounts.
2. Do not mount controls in areas of high dust or cor-
rosive atmospheres without a protective enclosure.
3 Do not use a converter or inverter for the power
source.
4. Do not mount control in high transient voltage
areas without an isolation transformer
5. Do not leave control box open.
6. Do not allow a local repair shop to repair the con-
trols, as we employ some very sophisticated compo-
nents that could be further damaged. For service, call
us directly: 800-323-2593

Related parts for DNC-T2101-B10

DNC-T2101-B10 Summary of contents

Page 1

... ENVIRONMENTAL Operating Temperature: -40°C to 65°C New cycle Storage Temperature: -40°C to 70°C PART NUMBER DNC-T2101-010 DNC-T2101-020 PART NUMBER BOX-A0606-CHNF ASL-00RED-NEMA 4 MSW-0DPST-011 Caution not mount controls in high vibration areas with- out shock mounts not mount controls in areas of high dust or cor- rosive atmospheres without a protective enclosure ...

Page 2

... Model DNC-2101-010 Model DNC-2101-020 Field Wiring Diagram AMETEK National Controls Corp. • 1725 Western Drive • West Chicago, Illinois 60185 • Tel: 800-323-2593 • 630-231-5900 • FAX: 630-231-1377 • www.nationalcontrols.com DUST COLLECTOR CONTROLS 5.125 .25 4.625 .25 DIA. 4 HOLES 1.8 sec. 180 Shake Time ...