G3PB-535B-3N-VD-DC1224 Omron Automation, G3PB-535B-3N-VD-DC1224 Datasheet - Page 3

no-image

G3PB-535B-3N-VD-DC1224

Manufacturer Part Number
G3PB-535B-3N-VD-DC1224
Description
Relay; SSR; Contactor; Cur-Rtg 35A; Ctrl-V 12-24DC; Vol-Rtg 200-480AC; DIN Rail Mnt
Manufacturer
Omron Automation
Datasheet

Specifications of G3PB-535B-3N-VD-DC1224

Current, Leakage, Off-state
20 mA
Current, Rating
35 A
Dielectric Strength
2500 VAC @ 50⁄50 Hz
Dimensions
140 mm (Max.) L x 80 mm (Max.) W
Function
Contactor
Impedance, Input
10 mA (Max.)
Mounting Type
DIN Rail
Power, Rating
29 kW
Relay Type
Solid State
Standards
UL, CSA, CE
Temperature, Ambient, Maximum
+80 °C
Temperature, Ambient, Minimum
-30 °C
Termination
Screw
Voltage, Control
24 VDC
Voltage, Rating
480 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
Specifications
■ Ratings (at an Ambient Temperature of 25 C)
Operating Circuit (Common)
Main Circuit of Models with Built-in Heat Sinks
Note: 1. The applicable load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in
Main Circuit of Models with Externally Attached Heat Sinks
Note: The applicable load current depends on the heat sink that is connected and the ambient temperature.
Rated voltage
Operating voltage range
Rated input current (Impedance)
Must operate voltage
Must release voltage
Insulation method
Operation indicator
Item
Rated load voltage 100 to 240 VAC
Load voltage range 75 to 264 VAC
Applicable load
current
(See note 1.)
Minimum load cur-
rent
Inrush current re-
sistance
(peak value)
Permissible I
(half 60-Hz wave)
Applicable load
(resistive load,
AC1) (See note 2.)
Item
Rated load
voltage
Load voltage
range
Applicable
load current
(See note.)
Minimum load
current
Inrush
current
resistance
(peak value)
Permissible
I
wave)
Applicable
load (resistive
load, AC1)
2
t (half 60-Hz
2. Applicable Load
For details, refer to Load Current vs. Ambient Temperature in Engineering Data on page 5.
Model
Engineering Data on page 5.
Use the following formula to calculate the maximum total capacity of a heater load for a three-phase balanced load with delta connections.
Maximum load capacity = Load current
Example: 15 A
Example: 15 A
2
Model
t
Item
100 to 240 VAC
75 to 264 VAC
15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C)
0.2 A
150 A (60 Hz,
1 cycle)
121 A
Refer to Engineering Data on page 5.
-3H-VD
G3PB
-215B
15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C) 15 A (at 40°C) 25 A (at 40°C) 35 A (at 25°C) 45 A (at 25°C)
0.2 A
150 A
(60 Hz, 1 cy-
cle)
121 A
5.1 kW max.
(at 200 VAC)
G3PB-
3N-VD
2
215B-
s
-2H-VD
G3PB
-215B
200 V
400 V
2
s
G3PB-
2N-VD
215B-
220 A (60 Hz,
1 cycle)
260 A
-3H-VD
G3PB
-225B
3
3
220 A
(60 Hz, 1 cy-
cle)
260 A
8.6 kW max.
(at 200 VAC)
G3PB-
3N-VD
12 to 24 VDC
9.6 to 30 VDC
10 mA max. (at 24 VDC)
9.6 VDC max.
1 VDC min.
Phototriac coupler
Yellow LED
225B-
2
s
= 5.196 W
= 10.392 W
-2H-VD
G3PB
-225B
2
s
G3PB-
2N-VD
225B-
0.5 A
440 A (60 Hz, 1 cycle)
1,260 A
-3H-VD
G3PB
-235B
Load voltage
5.1 kW
0.5 A
440 A
(60 Hz, 1 cycle)
1260 A
12.1 kW max.
(at 200 VAC)
G3PB-
3N-VD
235B-
10.3 kW
Common
2
-2H-VD
s
G3PB
-235B
2
G3PB-
2N-VD
s
235B-
-3H-VD
G3PB
-245B
15.5 kW max.
(at 200 VAC)
3
G3PB-
3N-VD
245B-
-2H-VD
G3PB
-245B
G3PB-
2N-VD
245B-
200 to 480 VAC
180 to 528 VAC
220 A (60 Hz, 1 cycle)
260 A
-3H-VD
G3PB
-515B
200 to 480 VAC
180 to 528 VAC
220 A
(60 Hz, 1 cycle)
260 A
12.5 kW max.
(at 480 VAC)
G3PB-
3N-VD
515B-
2
s
-2H-VD
2
G3PB
-515B
s
G3PB-
2N-VD
515B-
-3H-VD
G3PB
-525B
20.7 kW max.
(at 480 VAC)
G3PB-
3N-VD
525B-
-2H-VD
G3PB
-525B
G3PB-
2N-VD
525B-
440 A (60 Hz, 1 cycle)
1,260 A
-3H-VD
G3PB
-535B
440 A
(60 Hz, 1 cycle)
1260 A
29.0 kW max.
(at 480 VAC)
G3PB-
3N-VD
535B-
G3PB-2N/-3N
2
-2H-VD
2
s
G3PB
-535B
G3PB-
2N-VD
s
535B-
-3H-VD
37.4 kW max.
(at 480 VAC)
G3PB-
3N-VD
G3PB
-545B
545B-
-2H-VD
G3PB-
2N-VD
545B-
G3PB
-545B