H7CX-A11D1DC12-24/AC24 Omron Automation, H7CX-A11D1DC12-24/AC24 Datasheet - Page 5

no-image

H7CX-A11D1DC12-24/AC24

Manufacturer Part Number
H7CX-A11D1DC12-24/AC24
Description
Counter; Digital; 12 VDC; Contact; LCD; 6; -99, 999 to 999999; 11 Pin Socket; 1
Manufacturer
Omron Automation
Type
Counterr
Datasheet

Specifications of H7CX-A11D1DC12-24/AC24

Color, Case
Black
Connection Type
11-Pin
Counter Type
Digital
Cut Out, Panel
45×45 mm
Dielectric Rating
2,000 VAC, 50⁄60 Hz for 1
Dimensions
72.5mmL×48mmW×48mmH
Display Digit Height
9mm (Main Display), 6mm (Sub-Display)
Display Range
-99,999 to 999999
Display Type
LCD
Frequency, Operating
5 kHz
Function
Counter
Memory Type
EEPROM
Mounting Type
Panel
Number Of Digits
6
Output Type
Contact
Primary Type
Electronic
Range, Measurement
-99999 to 999999
Resistance, Insulation
100 M≠ (Min.) @ 500 VDC
Special Features
Programmable
Stage Setting
1
Standards
UL Recognized, cUL Listed, CE Marked
Temperature, Operating, Range
-10 to +55 °C
Terminal Type
11 Pin Socket
Termination
11 Pin Socket
Voltage, Supply
24/12 to 24 VAC/VDC
Lead Free Status / Rohs Status
RoHS Compliant part
■ Ratings (contd.)
Note: 1. Permissible ripple: 20% (p-p) max.
Classification
Supported configurations
Rated supply voltage (See note 1.)
Operating voltage range
Power consumption
Mounting method
External connections
Terminal screw tightening torque
Display (See note 2.)
Digits
Input signals
Input method
Counter
Tachometer
Output type
Control output
External power supply
Key protection
Prescaling function
Decimal point adjustment
Sensor waiting time
Memory backup
Ambient temperature
Ambient humidity
Case color
Attachments
2. The display is lit only when the power is ON.
3. Only when the following modes are selected.
- Input mode: command, individual, or quadrature; output mode: K-2, D, L, or H
- Dual count calculating mode: SUB; output mode: K-2, D, L, or H in dual counter operation
Max. counting speed
Input mode
Reset input
Reset system
Output modes
One-shot output time
Pulse measurement
method
Max. counting speed
Measuring ranges
Measuring accuracy
Output modes
Auto-zero time
Startup time
Average processing
Item
PV
SV
Preset counter
1-stage counter, 2-stage counter, 1-stage
counter with total counter, 1-stage counter
with batch counter, dual counter (addition
only) (selectable)
100 to 240 VAC (50/60 Hz),
12 to 24 VDC
85% to 110% of rated supply voltage (90% to 110% at 12 VDC)
Approx. 9.2 VA at 264 VAC
Approx. 7.2 VA at 26.4 VAC
Approx. 3.7 W at 12 VDC
Flush mounting
Screw terminals
0.5 N·m max.
7-segment, negative transmissive LCD
11.5-mm-high characters, red or green
(programmable)
6-mm-high characters, green
4 digits (−999 to 9,999)
SV range: 0 to 9,999
CP1, CP2, reset 1, and reset 2
No-voltage input/voltage input (switchable)
No-voltage input
ON impedance: 1 kΩ max. (Leakage current: 5 to 20 mA at 0 Ω)
ON residual voltage: 3 V max.
OFF impedance: 100 kΩ min.
Voltage input
High (logic) level: 4.5 to 30 VDC
Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 kΩ)
30 Hz or 5 kHz (selectable, ON/OFF ratio 1:1), common setting for CP1 and CP2
Increment, decrement, command, individual, and quadrature
Minimum reset input signal width: 1 or 20 ms (selectable), common setting for all inputs
External, manual, and automatic reset (internal according to C, R, P, and Q mode operation)
N, F, C, R, K-1, P, Q, A
0.01 to 99.99 s
---
---
---
---
---
---
---
---
H7CX-A4W/-AW/-AWD1: SPDT (OUT2) and SPST-NO (OUT1)
H7CX-A4WSD/-AWS/-AWSD/-AWSD1: 2 transistors
Contact output:
Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value)
Transistor output:
NEMA B300 Pilot Duty, 1/4 HP 3-A resistive load at 120 VAC, 1/3 HP 3-A resistive load at 240 VAC
12 VDC (±10%), 100 mA (except for H7CX-A@D models)
Refer to Safety Precautions (Common) on page 59 for details.
Yes
Yes (0.001 to 9.999)
Yes (rightmost 3 digits)
250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.)
EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min.
Operating: −10 to 55°C (−10 to 50°C if counters are mounted side by side) (with no icing or condensation)
Storage:
25% to 85%
Black (N1.5), light gray (Munsell 5Y7/1, produced upon request)
Waterproof packing, flush mounting adapt-
er
−25 to 65°C (with no icing or condensation)
H7CX-A4W@
3 A at 250 VAC/30 VDC, resistive load (cosφ=1)
NPN open collector, 100 mA at 30 VDC
Residual voltage: 1.5 VDC max. (approx. 1 V)
Leakage current: 0.1 mA max.
Preset counter/tachometer
1-stage counter, 2-stage counter, 1-stage counter with total counter, 1-stage counter with batch
counter, dual counter (addition/subtraction), tachometer (selectable)
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24 VDC,
12 to 24 VDC
9-mm-high characters, red or green (programmable)
6 digits (−99,999 to 999,999 or 0 to 999,999 when using as Tachometer)
SV range: −99,999 to 999,999 (See note 3.) or 0 to 999,999
N, F, C, R, K-1, P, Q, A, K-2, D, L, H
Periodic measurement (Sampling period: 200 ms)
30 Hz or 10 kHz (selectable)
30 Hz: 0.01 to 30.00 Hz
10 kHz: 0.01 Hz to 10 kHz
±0.1% FS ±1 digit max. (at 23 ±5°C)
HI-LO, AREA, HI-HI, LO-LO
0.1 to 99.9 s
0.0 to 99.9 s
OFF/2/4/8 times
Yes (0.001 to 99.999)
Waterproof packing, flush mounting adapter, labels for counter/tachometer DIP switch settings
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
H7CX-AW@
100 to 240 VAC (50/60 Hz),
24 VAC (50/60 Hz)/12 to 24 VDC
H7CX-AU/-AUD1: SPDT and 1 transistor
H7CX-AUSD1: 2 transistors
(Output allocation possible)
H7CX-AU@
H7CX-A
5

Related parts for H7CX-A11D1DC12-24/AC24