VBA40A-T04-Z SMC Corporation, VBA40A-T04-Z Datasheet

no-image

VBA40A-T04-Z

Manufacturer Part Number
VBA40A-T04-Z
Description
BOOSTER REGULATOR, 1/2 NPTF PORT, HANDLE OPERATED TYPE, PSI
Manufacturer
SMC Corporation
Datasheet

Specifications of VBA40A-T04-Z

Brand/series
VBA Series
Flow Rate
1900 SCFM
Pressure Adjustment
Handle Operating
Pressure Increase Ratio
Twice
Pressure, Operating
1 MPa
Proof Pressure
1.5 MPa
Size, Port
1⁄2 in.
Temperature, Ambient
2 to 50
Thread Type
NPTF
Series
Increase factory air pressure by up
Increase factory air pressure by up to to
Increase factory air pressure by up to
Air-only operation requires no power supply,
Air-only operation requires no power supply,
Air-only operation requires no power supply,
reduces heat generation, and
reduces heat generation, and
reduces heat generation, and
allows easy installation.
allows easy installation.
allows easy installation.
Booster Regulator/Air Tank
There is no need to
install dedicated
electrical wiring.
Very little heat is
generated because
no electricity is
used, and there is
no impact on
cylinders, solenoid
valves, etc.
No power supply or wiring needed
Low heat generation
Renewed model with
pressure increase ratio
2
NEW
to
4
Booster Regulator/
times
VBA/VBAT
(VBA11A)
Compressor
Series
Factory line
0.3
MPa
VBA
0.3
0.3
0.3
MPa
MPa
MPa
Simply insert the unit
in the air line.
Requires far less
space than installing
the compressor.
Operation is safe
because no
electricity is used.
Booster Regulator + Air Tank
Easy installation
Air-only operation
Boost pressure
4 4
4
Air Tank/
times!
times!
times!
Light
Light
0.6
Series
MPa
VBAT
CAT.ES11-96D
Heavy
New
New
RoHS

Related parts for VBA40A-T04-Z

VBA40A-T04-Z Summary of contents

Page 1

Booster Regulator/Air Tank Increase factory air pressure by up Increase factory air pressure Increase factory air pressure Air-only operation requires no power supply, Air-only operation requires no power supply, Air-only operation requires no ...

Page 2

... Max. operating pressure VBA43A Reduced by Reduced by Reduced by compared with the conventional model compared with the conventional model compared with the conventional model Bumper Cylinder tube Tie-rod guide Air-feeding tube VBA40A Gauge port VBA10A 1.6 Fourfold pressure MPa increase type NEW VBA11A ...

Page 3

... Set pressure range 0.2 to 1.0 MPa Body size 1/4" VBA20A-03 3/8" VBA40A-04 1/2" Air Tank VBAT Series Perfect fit with a booster regulator This is an air tank to which a booster regulator can be connected compactly. It can be used alone as a tank. The pressure vessel law is different from country to country air tank suitable to a country needs to be confirmed ...

Page 4

... Air-operated type 43A 1/2", Max. operating pressure 1.6 MPa 11A 1/4", Handle-operated type Symbol Note) Thread types apply to the IN, OUT, VBA10A-02 VBA11A-02 VBA20A-03 VBA22A-03 VBA40A-04 VBA42A-04 1 VBA How to Order VBA 40A 04 Body size Pressure increase ratio: Twice Pressure increase ...

Page 5

... VBA40A-04 VBA22A-03 VBA20A-F03 VBA40A-F04 VBA22A-F03 G36-10-01 KT-VBA22A-7 AN300-03 AN400-04 AN300-03 ANA1-03 ANA1-04 — — VBA20A-N03 ∗ VBA40A-N04 ∗ VBA22A-N03 ∗ VBA20A-T03 ∗ VBA40A-T04 ∗ VBA22A-T03 ∗ ” ∗ : when “ ” ∗ : when “ ” G36-10-N01 KT-VBA22A-7N G36-P10-N01 KT-VBA22A-8N AN300-N03 AN400-N04 ...

Page 6

... Inlet pressure (MPa) Charge Characteristics 1.0 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2.0 /P Pressure increase ratio VBA40A, 42A b The time required to charge pressure in the tank from 0.8 MPa to 1.0 MPa at 0.5 MPa supply pressure: 0 1.6 P 0.5 P ...

Page 7

VBA43A Flow-rate Characteristics 1.6 1.4 1.2 1 0.8 0 0.4 0.2 0 500 1000 1500 2000 2500 3000 Outlet air flow rate (L/min (ANR)) Pressure Inlet pressure: 0.7 MPa (Representative Outlet pressure: 1.0 MPa Characteristics ...

Page 8

VBA Series ( Sizing can be achieved with the SMC Pneumatic System Energy Saving Program Ver. 3.1 Sizing which can be downloaded from the SMC website: http://www.smcworld.com START Necessary conditions: D [mm]: Cylinder bore size L [mm]: Cylinder ...

Page 9

Working Principle The IN air passes through the check valve to booster chambers A and B. Meanwhile, air is supplied to drive chamber B via the governor and the switching valve. Then, the air pressure from drive chamber B and ...

Page 10

VBA Series Design Warning 1. Warning concerning abnormal outlet pressure • If there is a likelihood of causing an outlet pressure drop due to unforeseen circumstances such as equipment malfunction, thus leading to a major problem, take safety measures on ...

Page 11

Caution 1. Setting the pressure on the handle-operated type • If air is supplied to the product in the shipped state, the air will be released. Set the pressure by quickly pulling up on the governor handle, releasing the lock, ...

Page 12

... VBA Series Construction/Replacement Parts VBA10A VBA20A, 22A, VBA40A, 42A, 43A Replacement Parts/Kit No. Place an order with the following applicable kit number. Model VBA10A Kit no. KT-VBA10A-1 The kit includes the parts from and a grease pack. VBA10A Model No. Description 1 Piston seal 2 Governor assembly 3 Check valve ...

Page 13

... IN side gauge port Rc 1 VBA20A-03 300 39 Pressure gauge (Option) IN side gauge port OUT side gauge port Rc 1 VBA40A-04 404 40 Pressure gauge (Option) IN side gauge port OUT side gauge port Rc 1/8 Rc 1/8 96 116 Pressure gauge (Option) OUT side 7 28 gauge port ...

Page 14

VBA Series Dimensions VBA22A-03 IN side gauge port Rc 1/8 VBA42A-04 IN side gauge port Rc 1/8 VBA43A-04 IN side gauge port Rc 1/8 Made to Order 1 Copper-free/Fluorine-free The inner or outer copper parts material has been changed to ...

Page 15

Air Tank Series • Compact connections are possible with booster regulators. • It can be used alone as a tank. • Also partially compatible with overseas standards VBAT05A1 VBAT10S1 VBAT20S1 VBAT38A1 Caution When used as a single unit (not connected ...

Page 16

VBAT Series Specifications Standard Product (For Japanese Market) VBAT05„1 VBAT10„1 VBAT20„1 VBAT38„1 Model Fluid Tank capacity (L) 5 VBAT„A1 Max. operating pressure (MPa) VBAT„S1 IN port size 3/8 OUT port size 3/8 Ambient and fluid temperature (°C) VBAT„A1 6.6 Weight ...

Page 17

List of Air Tank for Overseas Country/Region Law Singapore, Factory Act Malaysia Thailand, Taiwan No applicable standard Options/Accessories/Part No. <Standard Product> For VBAT„A1 (Carbon Steel) Model Accessory kit Note 1) 2) Safety valve (When selecting an option) VBAT-R (Set pressure: ...

Page 18

... Booster regulator IN port C C EXH: EXH: OUT 4 x ø ø13 100 200 A B Booster regulator model VBA20A 481 394 Rc 3/8 VBA40A 520 429.8 Rc 1/2 VBA22A 444 394 Rc 3/8 VBA42A 477 429.8 Rc 1/2 Note) When option G (pressure gauge) is selected 4 x ø11 C (mm) C ...

Page 19

... Connected to VBA22A, 42A Booster regulator IN port C C EXH: OUT 4 x ø13 150 250 A Booster regulator model VBA20A 531 444 VBA40A 570 479.8 VBA22A 494 444 VBA42A 527 479.8 Note) When option G (pressure gauge) is selected Booster regulator IN port Rc 1/4 EXH: Rc 1/4 OUT 4 x ø ...

Page 20

... Connected to VBA22A, 42A, 43A Booster regulator IN port C C EXH: OUT 4 x ø13 150 250 Booster regulator model A B VBA20A 531 444 VBA40A 570 479.8 VBA22A 494 444 VBA42A 527 479.8 VBA43A — 576 Note) When option G (pressure gauge) is selected 20 R A1- ...

Page 21

Dimensions: CE Certified Product A-Q Material: Carbon steel VBAT05 Connected to VBA10A, 11A Safety valve port Rc 3/8 60 Tank OUT port Rc 3/8 32 Drain port Rc 1/4 ∗ The length may be longer than the specification if the ...

Page 22

... Booster regulator IN port C C EXH: OUT 4 x ø13 150 150 250 250 Booster regulator model A B VBA20A 531 444 Rc 3/8 VBA40A 570 479.8 Rc 1/2 VBA22A 494 444 Rc 3/8 VBA42A 527 479.8 Rc 1/2 Note) When option G (pressure gauge) is selected C EXH ø13 (mm) ...

Page 23

Dimensions: Product Not Applicable to the ASME Standard A1-X11 Material: Carbon steel VBAT05 Connected to VBA10A, 11A Safety valve port Tank IN port Rc 3 Tank OUT port Rc 3 Drain port Rc 1/4 ...

Page 24

... Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 Fax: 03-5298-5362 URL http://www.smcworld.com © 2010 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of “ ...

Related keywords