E2E-X10ME1 Omron Automation, E2E-X10ME1 Datasheet - Page 10

no-image

E2E-X10ME1

Manufacturer Part Number
E2E-X10ME1
Description
Sensor, Proximity; Inductive Sensing Mode; M18; NPN; 10 mm; -40 to degC
Manufacturer
Omron Automation
Type
Inductiver
Datasheet

Specifications of E2E-X10ME1

Body Style
Cylindrical
Current, Switching
200 mA
Function
Proximity
Ip Rating
IP67
Mounting Type
M18 Threaded
Output
NPN
Primary Type
Proximity
Range, Measurement
10 mm
Standards
IEC Approved, NEMA Approved
Technology
Inductive
Temperature, Operating
-40 to +85 °C
Termination
Pre-Wired
Vibration
10 to 55 Hz
Voltage, Supply
24 VDC
Voltage, Switching
2 V
Lead Free Status / Rohs Status
RoHS Compliant part
E2E-C@C/B@ and E2E-X1C/B@ DC 3-Wire Models
* The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing object
Response frequency
Power supply voltage
(operating voltage range)
Current consumption
Control
output
Indicators
Operation mode
(with sensing object
approaching)
Protection circuits
Ambient
temperature range
Ambient humidity range
Temperature influence
Voltage influence
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Degree of protection
Connection method
Weight (packed state)
Materials
Accessories
a set distance of half the sensing distance.
Load
current
Residual
voltage
Case
Sensing
surface
Clamping
nuts
Toothed
washer
Shielded
Model
*
Size
0.6 mm ±15%
0 to 0.4 mm
15% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 14.)
Iron, 3 × 3 × 1 mm
2 kHz
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
10 mA max.
Open-collector output,
80 mA max. (30 VDC max.)
1 V max.
Cable length: 2 m)
Operation indicator (red)
C1/B1 Models: NO
C2 Models: NC
Reverse polarity protection, Surge suppressor
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95%
±15% max. of sensing distance at 23°C in the temperature range of −25 to 70°C
±5% max. of sensing dis-
tance at rated voltage in the
rated voltage ±10% range
50 MΩ min. (at 500 VDC) between current-carrying parts and case
500 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Destruction: 500 m/s
IEC 60529 IP66
Pre-wired Models (Standard cable length: 2 m)
Approx. 60 g
Stainless steel (SUS303)
Heat-resistant ABS
Nickel-plated brass (E2E-X1C/B@ only)
Zinc-plated iron (E2E-X1C/B@ only)
Instruction manual
(Load current: 80 mA,
E2E-CR6C/B@
3 dia.
2
10 times each in X, Y, and Z directions
Refer to the timing charts under I/O Circuit Diagrams on page 17 for details.
0.8 mm ±15%
0 to 0.5 mm
Iron, 5 × 5 × 1 mm
3 kHz
17 mA max.
Open-collector output, 100 mA max. (30 VDC max.)
2 V max. (Load current: 100 mA, Cable length: 2 m)
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range
IEC 60529 IP67, in-house standards: oil-resistant
E2E-CR8C/B@
4 dia.
Shielded
1 mm ±15%
0 to 0.7 mm
Nickel-plated brass
E2E-X1C/B@
M5
E2E-C1C/B@
5.4 dia.
E2E
10

Related parts for E2E-X10ME1