VBA10A-T02GN-Z SMC Corporation, VBA10A-T02GN-Z Datasheet - Page 24

no-image

VBA10A-T02GN-Z

Manufacturer Part Number
VBA10A-T02GN-Z
Description
Booster regulator, pressure gauge, silencer, NPTF, ratio 2x, 230 l/min, 1/4 in
Manufacturer
SMC Corporation
Datasheet

Specifications of VBA10A-T02GN-Z

Brand/series
VBA Series
Flow Rate
230 SCFM
Pressure Adjustment
Handle Operating
Pressure Increase Ratio
Twice
Pressure, Operating
1 MPa
Proof Pressure
3.0 MPa
Size, Port
1⁄4 in.
Temperature, Ambient
2 to 50
Thread Type
NPTF
Akihabara UDX 15F,
4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN
Phone: 03-5207-8249 Fax: 03-5298-5362
URL http://www.smcworld.com
© 2010 SMC Corporation All Rights Reserved
Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.
2. Only personnel with appropriate training should operate
3.
4. Contact SMC beforehand and take special consideration of safety
1. The compatibility of the product is the responsibility of the
2. When the product is to be removed, confirm that the safety measures as
3. Before machinery/equipment is restarted, take measures to prevent
measures if the product is to be used in any of the following
conditions.
1. Conditions and environments outside of the given specifications, or use
2. Installation on equipment in conjunction with atomic energy, railways, air
3. An application which could have negative effects on people, property, or
4. Use in an interlock circuit, which requires the provision of double interlock for
person who designs the equipment or decides its specifications.
Since the product specified here is used under various operating conditions, its
compatibility with specific equipment must be decided by the person who designs
the equipment or decides its specifications based on necessary analysis and test
results. The expected performance and safety assurance of the equipment will be
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the
equipment.
machinery and equipment.
The product specified here may become unsafe if handled incorrectly. The
assembly, operation and maintenance of machines or equipment including our
products must be performed by an operator who is appropriately trained and
experienced.
machinery/equipment until safety is confirmed.
1. The inspection and maintenance of machinery/equipment should only be
Edition B
Edition C
Do
performed after measures to prevent falling or runaway of the driven objects
have been confirmed.
mentioned above are implemented and the power from any appropriate source
is cut, and read and understand the specific product precautions of all relevant
products carefully.
unexpected operation and malfunction.
outdoors or in a place exposed to direct sunlight.
navigation, space, shipping, vehicles, military, medical treatment, combustion
and recreation, or equipment in contact with food and beverages, emergency
stop circuits, clutch and brake circuits in press applications, safety equipment
or other applications unsuitable for the standard specifications described in the
product catalog.
animals requiring special safety analysis.
possible failure by using a mechanical protective function, and periodical
checks to confirm proper operation.
Safety Instructions
Caution:
Warning:
Danger :
not
Safety Instructions
∗ Addition of booster regulators/air-operated type, VBA22A/42A
∗ Addition of booster regulator with max. operating pressure of
∗ Number of pages increased from 24 to 28
∗ Addition of booster regulator, VBA10A
∗ Deletion of booster regulator, VBA1110
∗ Number of pages decreased from 28 to 20
1.6 MPa, VBA43A
Change of accessories/part no. of air tank, VBAT series
Change of dimensions of air tank, VBAT series
service
Caution
which, if not avoided, could result in minor or
moderate injury.
Warning
risk which, if not avoided, could result in death or
serious injury.
Danger
which, if not avoided, will result in death or serious
injury.
or
Warning
attempt
indicates a hazard with a high level of risk
indicates a hazard with a low level of risk
indicates a hazard with a medium level of
Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.
to
remove
These safety instructions are intended to prevent hazardous situations and/or
equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)
and other safety regulations.
product
and
MY
NY
Limited warranty and Disclaimer/
Compliance Requirements
The product used is subject to the following “Limited warranty and Disclaimer”
and “Compliance Requirements”.
Read and accept them before using the product.
Limited warranty and Disclaimer
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Compliance Requirements
1. The warranty period of the product is 1 year in service or 1.5 years after
2. For any failure or damage reported within the warranty period which is clearly our
3. Prior to using SMC products, please read and understand the warranty terms
1. The use of SMC products with production equipment for the manufacture of
2. The exports of SMC products or technology from one country to another are
1. The product is provided for use in manufacturing industries.
D-DN
Edition D
The product herein described is basically provided for peaceful use in
manufacturing industries.
If considering using the product in other industries, consult SMC beforehand and
exchange specifications or a contract if necessary.
If anything is unclear, contact your nearest sales branch.
the product is delivered.
Also, the product may have specified durability, running distance or
replacement parts. Please consult your nearest sales branch.
responsibility, a replacement product or necessary parts will be provided.
This limited warranty applies only to our product independently, and not to any
other damage incurred due to the failure of the product.
and disclaimers noted in the specified catalog for the particular products.
weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
governed by the relevant security laws and regulations of the countries involved
in the transaction. Prior to the shipment of a SMC product to another country,
assure that all local rules governing that export are known and followed.
ISO 4413: Hydraulic fluid power – General rules relating to systems.
IEC 60204-1: Safety of machinery – Electrical equipment of machines.
ISO 10218-1: Manipulating industrial robots - Safety.
etc.
∗2) Vacuum pads are excluded from this 1 year warranty.
A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
or failure due to the deterioration of rubber material are not covered by the limited warranty.
∗ Addition of booster regulator, VBA11A
∗ Deletion of booster regulator, VBA1111
∗ Addition of air tanks, CE certified
∗ Addition of air tanks, not applicable to the ASME standard
∗ Addition of an elbow silencer to options
∗ Number of pages increased from 20 to 24
(Part 1: General requirements)
1st printing MP printing OW 7150SZ Printed in Japan.
∗2)
Caution
OW
∗1)
,

Related parts for VBA10A-T02GN-Z