R10A-12-N Cosel U.S.A. Inc., R10A-12-N Datasheet - Page 2

no-image

R10A-12-N

Manufacturer Part Number
R10A-12-N
Description
Power Supply; 85 to 132 VAC/110 to 170 VDC; 12 V; 0.9 A; 10.8 W (Max.)
Manufacturer
Cosel U.S.A. Inc.
Datasheet

Specifications of R10A-12-N

Brand/series
R Series
Configuration
Enclosed
Current, Output
0.9 A
Dimensions
26 mm W x 68 mm H x 68 mm D
Frequency, Input
47 to 440 Hz
Mounting Type
Panel
Number Of Outputs
1
Operation
Linear
Output
12 VDC @ 0.9 A
Power, Output
10.8 W
Power, Rating
10.8 W (Max.)
Primary Type
AC-DC
Standards
UL1950, cUL Complies with DEN-AN
Temperature, Operating
-10 to +60 °C
Voltage, Input
85 to 132/110 to 170 VAC/VDC
Voltage, Output
12 VDC
Standard Input
AC 85 ~ 132
Lead Free Status / Rohs Status
RoHS Compliant part
R
INPUT
OUTPUT
PROTECTION
CIRCUIT AND
OTHERS
ISOLATION
ENVIRONMENT
SAFETY AND
NOISE
REGULATIONS
OTHERS
SPECIFICATIONS
MODEL
MAX OUTPUT WATTAGE[W]
DC OUTPUT
*1
*
*
*
A-100
Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C, with the input voltage held constant at the rated input/output.
Avoid prolonged use under over-load.
Series/Parallel operation with other model is not possible.
Derating is required when operated with case cover.
R
MODEL
VOLTAGE[V]
CURRENT[A]
FREQUENCY[Hz]
EFFICIENCY[%]
INRUSH CURRENT[A] ACIN 100V 20typ ( Io=100% ) ( At cold start )
LEAKAGE CURRENT[mA] 0.5max ( According to UL , CSA and DEN-AN )
VOLTAGE[V]
CURRENT[A]
LINE REGULATION[mV]
LOAD REGULATION[mV] 40max
RIPPLE[mVp-p]
RIPPLE NOISE[mVp-p]
TEMPERATURE REGULATION[mV]
DRIFT[mV]
START-UP TIME[ms]
HOLD-UP TIME[ms]
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.85 - 3.6
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically ( ACIN 100V )
OVERVOLTAGE PROTECTION 4.00V min
OPERATING INDICATION LED ( Green )
REMOTE SENSING
REMOTE ON/OFF
INPUT-OUTPUT
INPUT-FG , COVER
OUTPUT-FG , COVER
OPERATING TEMP. , HUMID.AND ALTITUDE -10 to +60 C , 20 - 90%RH ( Non condensing ) ( Refer to DERATING CURVE ), 3 , 000m ( 10 , 000feet ) max
STORAGE TEMP. , HUMID.AND ALTITUDE -20 to +75 C , 20 - 90%RH ( Non condensing ), 9 , 000m ( 30 , 000feet ) max
VIBRATION
IMPACT
AGENCY APPROVALS
CONDUCTED NOISE
CASE SIZE/WEIGHT
COOLING METHOD
R10A
Unit type
ACIN 100V 0.24typ ( Io=100% )
0 to +50 C 80max
-10 - 0 C 140max
0 to +50 C 120max
-10 - 0 C 160max
0 to +50 C 50max
-10 to +50 C 60max
* 1
R10A-3
6
3V 2.0A
R10A-3
AC85 - 132 1 f or DC110 - 170
47 - 440 or DC
64typ
3
2.0
20max
20max
100max ( ACIN 85V , Io=100% )
10typ ( ACIN 85V , Io=100% , 0 to +50 C ) 20typ ( ACIN 100V , Io=100% , 0 to +50 C )
Not provided
Not provided
AC2 , 000V 1minute , Cutoff current = 10mA max , DC500V 50M W min ( At Room Temperature )
AC2 , 000V 1minute , Cutoff current = 10mA max , DC500V 50M W min ( At Room Temperature )
AC500V 1minute , Cutoff current = 100mA max , DC500V 50M W min ( At Room Temperature )
10 - 55Hz , 19.6m/s
196.1m/s
UL60950-1 , C-UL Complies with DEN-AN
Complies with FCC-B , VCCI-B
26 X 68 X 68mm ( W X H X D ) /150g max ( without cover )
Convection
2
( 20G ), 11ms , once each X , Y and Z axis
2
( 2G ), 3minutes period , 60minutes each along X , Y and Z axis
R10A-5
10
5V 2.0A
R10A-5
70typ
5
2.0
20max
40max
80max
140max
120max
160max
50max
60max
20max
4.5 - 5.5
Works over 115% of rating ( By zener diode clamping )
1
Ordering information
R
R10A-12
10.8
12V 0.9A
R10A-12
75typ
12
0.9
48max
100max
120max
160max
150max
180max
120max
150max
48max
10.8 - 13.2
2
10A
3
-5
R10A-15
10.5
15V 0.7A
R10A-15
76typ
15
0.7
60max
120max
120max
160max
150max
180max
150max
180max
60max
13.5 - 16.5
4
-O
1Series name
2Output wattage
3Output voltage
4Optional
G :Low leakage current
J :Connector type
N :with Cover
R10A-24
12
24V 0.5A
R10A-24
78typ
24
0.5
96max
150max
120max
160max
150max
180max
240max
290max
96max
21.6 - 26.4

Related parts for R10A-12-N