KSZ8041NL TR Micrel Inc, KSZ8041NL TR Datasheet - Page 26

IC TXRX PHY 10/100 LV/LP 32-MLF

KSZ8041NL TR

Manufacturer Part Number
KSZ8041NL TR
Description
IC TXRX PHY 10/100 LV/LP 32-MLF
Manufacturer
Micrel Inc
Type
Transceiverr
Datasheets

Specifications of KSZ8041NL TR

Number Of Drivers/receivers
1/1
Protocol
MII, RMII
Voltage - Supply
3.135 V ~ 3.465 V
Mounting Type
Surface Mount
Package / Case
32-MLF®, QFN
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
576-1621 - BOARD EVALUATION FOR KSZ8041NL
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
Other names
576-1645-2
KSZ8041NLTR
KSZ8041NLTR
Micrel, Inc.
RMII Signal Definition
The Tables 3 and 4 describe the RMII signals for KSZ8041NL and KSZ8041RNL. Refer to RMII Specification for detailed
information.
Reference Clock (REF_CLK)
REF_CLK is a continuous 50MHz clock that provides the timing reference for TX_EN, TXD[1:0], CRS_DV, RXD[1:0], and
RX_ER.
The KSZ8041NL inputs the 50MHz REF_CLK from the MAC or system board.
The KSZ8041RNL generates the 50MHz RMII REF_CLK and outputs it to the MAC.
Transmit Enable (TX_EN)
TX_EN indicates that the MAC is presenting di-bits on TXD[1:0] for transmission. It is asserted synchronously with the first
nibble of the preamble and remains asserted while all di-bits to be transmitted are presented on the RMII, and is negated
prior to the first REF_CLK following the final di-bit of a frame.
TX_EN transitions synchronously with respect to REF_CLK.
Transmit Data [1:0] (TXD[1:0])
TXD[1:0] transitions synchronously with respect to REF_CLK. When TX_EN is asserted, TXD[1:0] are accepted for
transmission by the PHY. TXD[1:0] is ”00” to indicate idle when TX_EN is de-asserted. Values other than “00” on TXD[1:0]
while TX_EN is de-asserted are ignored by the PHY.
September 2010
RMII
Signal Name
REF_CLK
TX_EN
TXD[1:0]
CRS_DV
RXD[1:0]
RX_ER
RMII
Signal Name
REF_CLK
TX_EN
TXD[1:0]
CRS_DV
RXD[1:0]
RX_ER
Direction
(with respect to PHY,
KSZ8041NL signal)
Input
Input
Input
Output
Output
Output
Direction
(with respect to PHY,
KSZ8041RNL signal)
Output
Input
Input
Output
Output
Output
Table 4. RMII Signal Description – KSZ8041RNL
Table 3. RMII Signal Description – KSZ8041NL
Direction
(with respect to MAC)
Output
Output
Input
Input
Input, or (not required)
Direction
(with respect to MAC)
Input
Output
Output
Input
Input
Input, or (not required)
Input, or Output
26
Description
Synchronous 50 MHz clock reference for
receive, transmit and control interface
Transmit Enable
Transmit Data [1:0]
Carrier Sense/Receive Data Valid
Receive Data [1:0]
Receive Error
Description
Synchronous 50 MHz clock reference for
receive, transmit and control interface
Transmit Enable
Transmit Data [1:0]
Carrier Sense/Receive Data Valid
Receive Data [1:0]
Receive Error
M9999-090910-1.4
KSZ8041NL/RNL