CS8130-CSZ Cirrus Logic Inc, CS8130-CSZ Datasheet - Page 20

IC IR TRANSCEIVER 2-5V 20-SSOP

CS8130-CSZ

Manufacturer Part Number
CS8130-CSZ
Description
IC IR TRANSCEIVER 2-5V 20-SSOP
Manufacturer
Cirrus Logic Inc
Type
Transceiverr
Datasheet

Specifications of CS8130-CSZ

Voltage - Supply
2.7 V ~ 5.5 V
Mounting Type
Surface Mount
Package / Case
20-SSOP
Data Rate
115Kbps
Supply Voltage Range
2.7V To 5.5V
Logic Case Style
SSOP
No. Of Pins
20
Operating Temperature Range
0°C To +70°C
Peak Reflow Compatible (260 C)
Yes
Interface
UART
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
598-1161 - BOARD EVAL FOR CS8130
Number Of Drivers/receivers
-
Protocol
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
598-1204-5

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS8130-CSZ
Manufacturer:
CIRRUS
Quantity:
20 000
Register 19, TV Remote Transmit Bit Rate Divider Register #1
Register 20, TV Remote Transmit Bit Rate Divider Register #2
Register 21, Control Register #4
20
20
TBR7-0
OSCE
OSCL
EXCK
SRES
Reset (R)
Reset (R)
Reset (R)
Register
Register
Register
BIT
BIT
TV remote mode
transmit bit rate
register
TBR=
(3.6864E6/(16*RATE))
-1
where TBR is this
register value &
RATE is the desired
transmit bit rate.
Disable crystal
oscillator in D/C
controlled
power down state
power mode
Disable external
clock output driver
Software Reset
Set oscillator in low
OSCE OSCL EXCK
TBR3 TBR2 TBR1
TBR7 TBR6
D3
D3
D3
1
0
0
NAME
NAME
D2
D2
D2
1
1
0
D1
D1
TBR5
D1
1
1
0
SRES
TBR0
D0
D0
D0
1
TBR4
1
0
01111111
0
1
0
1
0
1
0
1
VALUE
VALUE
127 R
R In D/C controlled power down state, crystal
R Oscillator in normal power, high accuracy, mode.
R If crystal is used, enable clock output driver
R Normal operation
oscillator stays running.
In D/C controlled power down state, crystal
oscillator stops.
Oscillator in low power, medium accuracy mode.
If crystal is used, disable clock output driver (Hi-Z)
Causes a software reset, which forces all registers
into their reset state. If ECHO is true, then the echo
will occur at the current baud rate, before the baud
rate changes to the default value.
RATE = 1800 bps
FUNCTION
FUNCTION
CS8130
CS8130
DS134PP2
DS134F1