H5CX-A-N AC100-240

Manufacturer Part Number
H5CX-A-N AC100-240
Description
Relay; E-Mech; Timing; Multi-Function; Cur-Rtg 5A; Ctrl-V 100-240AC; REPL:H5CX-AAC1002
Manufacturer
Omron Automation
Type
Timerr
Datasheet

Specifications of H5CX-A-N AC100-240

Brand/series
H5CX
Connection Type
Screw Terminals
Contact Form
5 A at 250VAC/30 VDC
Dimensions
58H x 48W x 98.5D
Display Type
7 Segment LCD
Function
Multifunction Digital Timer
Input Type
Signal, Reset and Gate
Ip Rating
IP66
Mounting Type
Flush
Number Of Inputs
3
Number Of Outputs
1
Output Type
SPDT
Primary Type
Digital Timer
Voltage, Supply
100-240 VAC
26
H5CX-A@-N/-L@-N
Twin Timer
To switch to twin timer operation, use the procedure given below. For details, refer to page 31.
• Change to Function Setting Mode.
Step3
To next page
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode.
Power ON
Run mode
Also, when settings are changed, the timer is reset (time initialized and output turned OFF).
From next page
Settings that cannot be performed with the DIP switch are performed with the operation keys.
OFF time
range
ON time
range
Timer mode
ON/OFF
start mode
Input signal
width
NPN/PNP
input
Display
color
Instantaneous/
time-limit
3 s min.
3 s min.
Function setting mode
*1
*2
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting).
If pin 1 of the DIP switch is set to ON, the setting items indicated in
Set the OFF time range using the
Set the ON time range using the
Set the timer mode using the
Set the twin timer output mode using the
Set the input signal width using the
Set the NPN/PNP input mode using the
Set the display color using the
Set the function (instantaneous or time-limit operation) for the instantaneous output (output 1)
using the
Note: Only Flicker OFF Start 1 or Flicker ON Start 1 can be selected for the H5CX-L8E@.
Note: Not displayed for models with instantaneous contact outputs.
Note: Displayed only for the H5CX-A @ and H5CX-A11@.
Note: Displayed only for models with terminal screws (H5CX-A @).
Note: Displayed only for models with instantaneous contact outputs.
(Instantaneous) (Time-limit)
(
(NPN input)
For details, refer to Time Range List.
For details, refer to Time Range List.
OFF start 1
(20 ms)
(UP)
toff
20ms
npn
red
1c1c
Flicker
(Red)
up
s
s
(PNP input)
) (
For details on operations in run mode, refer to page 28.
(DOWN)
grn
(Green)
pnp
down
On Start 1
(1 ms)
1ms
Flicker
ton
2c
Keys.
s
s
(Orange)
org
) (
OFF start 2
tof1
Flicker
(Red-green)
r-g
s
s
) (
keys.
keys.
On Start 2
keys.
Flicker
ton1
keys.
……
……
(Green-red)
keys.
g-r
keys.
keys.
)
(Red-orange)
r-o
h
h
(Orange-red)
will not be displayed.
o-r
s
s
(Green-orange) (Orange-green)
g-o
Time Range List
o-g
Display
0.01 s to 99.99 s
(default setting)
0.1 s to 999.9 s
1 s to 9999 s
0 min 01 s to
99 min 59 s
0.1 min to
999.9 min
1 min to
9999 min
0 h 01 min to
99 h 59 min
0.1 h to 999.9 h
1 h to 9999 h
0.001 s to
9.999 s
Set Value