H3CR-F8 AC100-240 Omron Automation, H3CR-F8 AC100-240 Datasheet - Page 8

no-image

H3CR-F8 AC100-240

Manufacturer Part Number
H3CR-F8 AC100-240
Description
Timer; Repeat Cycle; 0.05s-30h; E-Mech; Ctrl-V 100-240AC; 5A@250VAC/30VDC; 8-Pin Octal
Manufacturer
Omron Automation
Datasheet

Specifications of H3CR-F8 AC100-240

Current, Rating
5 A
Function
Timing
Mounting Type
Socket
Number Of Pins
8
Relay Type
Electro Mechanical
Repeatability
±0.3% (Max.)
Standards
UL, CSA, CE
Temperature, Operating, Maximum
+55 °C
Temperature, Operating, Minimum
-10 °C
Termination
Plug-In
Timer Type
Repeat Cycle
Timing Range
0.05s-30h
Voltage, Control
100-240 VAC
Voltage, Rating
250 VAC⁄30 VDC VAC⁄VDC
Timing Functions
4 Function
6 Function
ON-Delay, Repeat Cycle ON or OFF, Signal ON/OFF, Signal OFF, Interval (11-Pin)
Timing Ranges
Multi-Function
Lead Free Status / Rohs Status
RoHS Compliant part
• H3CR-G Star-delta Timers
A star operation time range (0 to 6, 0 to 12, 0 to 60, or 0 to 120
seconds) is selected with the star operation time range selector at
the lower left corner of the front panel.
The time required for switching (0.05, 0.1, 0.25, or 0.5 second) from
the star operation to the delta operation of the H3CR-G can be
selected with the star-delta transfer time selector at the lower right
corner of the front panel.
■ Using the Time Setting Ring for H3CR-A/-G
Setting a Specific Time
Mount the Panel Cover on the Timer, set the desired time with the
time setting knob, and place Time Setting Ring A onto the time
setting knob so that the time setting notch of Time Setting Ring A is
in the center of the reset lock position of the Panel Cover.
Time Setting Ring A Panel cover
Time setting
notch
Star operation time
range selector
Reset lock position
Time setting notch
Example: To set the time to 10 s.
Star-delta transfer
time selector
Setting position
• H3CR-H Power OFF-delay Timers
A time range (0 to 0.6, 0 to 1.2, 0 to 6, and 0 to 12) is selected with
the time range selector at the lower left corner of the front panel. No
time unit selector is available. When ordering the H3CR-H, specify S
(for the second unit) or M (for the minute unit) for your H3CR-H.
Setting of Time
Use the time setting knob to set the desired time.
Limiting the Setting Range
Example: To set a range of 10 and 20 s.
Mount the Panel Cover on the Timer, set the time setting knob to 10 s
(the lower limit of the setting range), and place Time Setting Ring C
onto the time setting knob so that the stopper of Time Setting Ring C
is on the right edge of the reset lock position of the Panel cover. Next,
set the time setting knob to 20 s (the upper limit of the setting range),
place Time Setting Ring B onto the time setting knob so that the
stopper of Time Setting Ring B is on the left edge of the reset lock
position of the Panel Cover.
Time Setting
Ring B
Stopper
Time Setting
Ring C
Time range
selector
Reset lock position
Panel cover
Range
H3CR
2