WDU18-250 Triad Magnetics, WDU18-250 Datasheet

no-image

WDU18-250

Manufacturer Part Number
WDU18-250
Description
Plug-In AC Adapters 120 to 18VDC 0.25A 12W
Manufacturer
Triad Magnetics
Datasheets

Specifications of WDU18-250

Mounting Style
Wall
Input Voltage (nominal)
120 V
Number Of Outputs
1
Output Power Rating
12 W
Output Voltage (channel 1)
18 V
Output Current (channel 1)
0.25 A
Dc Output Connector
2.1 mm Barrel Plug
Dc Output Cord Length
6 ft
Ac Plug Included/required
Included
Commercial/medical
Commercial
Configuration
Wall Plug
Current, Rating
0.25 A
Frequency
60 Hz
Height
2-1⁄2 in.
Length
2 in.
Output
18 VDC @ 0.25 A
Power, Output
12 W
Primary Type
AC-DC
Standards
UL Recognized
Voltage, Input
120 VAC
Voltage, Output
18 VDC
Voltage, Rating
120 VAC
Width
1-5⁄8 in.
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
WDU18-250
Electrical Specifications (@25C)
1. Primary Rating: 120V 60Hz 12.0W
2. Primary Excitation Current: 60mA Max
3. Secondary Rating: 18VDC ± 5%, 250mADC
4. Secondary No-Load Rating: 26.5VDC Ref.
5. Output Ripple Voltage: 800mV Max
6. Operating Temperature Range: -10 Deg C to +40 Deg C
7. Temperature Rise: 70 Deg C Max at rated load
Mechanical Parameters:
Case Type: Thermoplastic molded enclosure.
Output Cord: 24 AWG, 6 Ft. Long Min.
Agency File:
UL/CUL: File E104603, UL 1310
CSA: LR67888
A. Dimensions:
B. Schematic:
Technical Note: 1. Inside (tip)-positive (+), outside-negative (-)
U.S. DOE Compliance per Sec. 301 of EISA 2007: As of July 1, 2008, this
product is intended for use as follows:
RoHS Compliance: As of manufacturing date February 2005, all standard
products meet the requirements of 2002/95/EC, known as the RoHS initiative.
* Upon printing, this document is considered “uncontrolled”. Please contact
Web: www.TriadMagnetics.com
Phone 951-277-0757
Fax 951-277-2757
120V
60HZ
Triad Magnetics’ website for the most current version.
1. Requires Federal Food and Drug Administration listing and approval
2. Powers the charger of a detachable battery pack or charges the
3. As a service part or a spare part for an end-use product manufactured
*Units: In Millimeter
as a medical device in accordance with section 513 of the Federal
Food, Drug, and Cosmetic Act (21 U.S.C. 360c)
battery of a product that is fully or primarily motor operated.
before July 1, 2008, that constitutes the primary load of this power
supply.
64
H
50 Deg C Max on enclosure surface
51
W
41
D
22520B Temescal Canyon Road
Corona, California
92883
Wall Plug - Ins
Publish Date: July 21, 2010
16UO
E104603
LISTED
U
NAMEPLATE
R
MODEL: WDU18-250
INPUT: 120V 60Hz 12W
OUTPUT: 18.0VDC .25A
CLASS 2 TRANSFORMER
L
MADE IN CHINA
AC ADAPTOR
AEC-T4118A
MARKING
LR67888
R

Related parts for WDU18-250