Specifications of MPU200-1048G

Product
Switching
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Output Specifications
PARAMETER
Efficiency
Minimum Load, V1
Minimum Load, V3
Ripple and Noise
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
Interface Signals and Internal Protection
PARAMETER
Overvoltage Protection
Overload Protection
Overtemperature Protection
Output Good Signal
Input Power Fail Warning
Current Share
Remote Sense
Inhibit
MCD10010 Rev. 1.1, 27-Jan-10
(Transision from
Low to High)
CONDITIONS/DESCRIPTION
Full Rated Load, 110 VAC (MPU) or 48VDC (MDU).
Varies with distribution of loads among outputs.
Minimum load required to maintain regulation on,
V2 at maximum load.
Minimum load required on single output models.
Minimum load required to maintain regulation on
V4 at maximum load.
Full load, 20 MHz bandwidth.
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
CONDITIONS/DESCRIPTION
Latch style overvoltage protection.
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
TTL compatible signal available for V1. Internal pull-up resistor is 475 .
Signal is high when output is above the specified limits. Signal shall
remain low for 20 milliseconds following loss of Output Good.
TTL compatible logic signal. Time before regulation dropout due to loss of input
power. May be used as independent PSOK signal in redundant applications.
Accuracy of shared current with up to 6 parallel units. Single wire current share
on V1 and V2 with return via -Sense return.
Available on V1 and V2. Total voltage compensation for cable losses with
respect to the main output.
Output voltage is inhibited by application of an external high (5V) signal.
Page 3 of 6
MPU200/MDU200 Series Data Sheet
MDU200/MPU200-1012 12V
MDU200/MPU200-1024 24V
MDU200/MPU200-1048 48V
MDU200/MPU200-1012 V1
MDU200/MPU200-1024 V1
MDU200/MPU200-1048 V1
MPU200-4530
MPU200-4530 12V output
MPU200-4530 3.3V output
Single output models V1
Quad output model V1
Quad output model V3
5V output
MPU200
MDU200
3.3V
5V
17.0
32.0
58.0
3.16
4.75
10.5
21.5
43.0
MIN
MIN
0.3
3.8
6.0
65
14
3
0
5
See Model Selection Charts
See Model Selection Charts
NOM
NOM
500
75
50
80
10
2
www.power-one.com
MAX
MAX
20.5
38.0
62.7
3.25
4.95
23.5
47.0
11.9
500
4.2
6.4
19
5
UNITS
UNITS
mV
ms
ms
μs
%
%
%
A
A
V
V
s