2CPSC1A2A Honeywell, 2CPSC1A2A Datasheet - Page 135

no-image

2CPSC1A2A

Manufacturer Part Number
2CPSC1A2A
Description
Control Switches SAFETY
Manufacturer
Honeywell
Datasheet

Specifications of 2CPSC1A2A

Control Type
Cable Pull Safety Switch
Contact Form
2 NC / 2 NO
Contact Rating
10 uAmps to 50 mAmps
Illuminated
Y
Lens Color
Red
Lead Free Status / Rohs Status
Compliant
SA Series
The harsh duty SA pressure transducer has a water resistant, stainless steel
case for complete protection from harsh environments. Internal hermetic
sealing is used to provide measurement from absolute pressures (psia) or
pressures referenced to a sealed chamber (psis). Underwriters Laboratories
has approved the SA as a component in float and pressure-operated motor
controllers (File #E93356).
Approvals:
Supply voltage:
Signal conditioning:
Operating temperature range:
Compensated temperature range:
Port style:
Output type:
Termination type:
OPTIONS
UL Approval
MEASUREMENT TYPE
Absolute
Absolute
Absolute
Absolute
Gauge
Sealed Gauge
Sealed Gauge
Sealed Gauge
Sealed Gauge
CE Approval
MEASUREMENT TYPE
Absolute
Absolute
Excitation: Red
Common: Blk
Signal: Wht
0,91 m long (3 ft)
(case shield)
shielded cable
3 conductor
color coded
Bare
SA WITH CABLE
(1.56)
40,0
PRESSURE RANGE
0 psia to 15 psia
0 psia to 25 psia
0 psia to 50 psia
0 psia to 100 psia
0 psig to 15 psig
0 psis to 100 psis
0 psis to 200 psis
0 psis to 500 psis
0 psis to 3,000 psis
PRESSURE RANGE
0 psia to 25 psia
0 psia to 50 psia
(0.38)
10,0
0,91 m (3 ft) 3-conductor shielded cable
1/8-27 NPT
3/8-24 UNF (optional ≥100 PSI)
1/2 Hex for 1/8-27 NPT port
9/16 Hex for 3/8-24 UNF port
-55 °C to 105 °C (-48 °F to 221 °F)
-1 °C to 85 °C (30 °F to 185 °F)
Amplified compensated
www.honeywell.com/sensing
CE (*C1DE products)
(1.88)
UL (*C1D products)
48,0
9.0 Vdc to 24.0 Vdc
REFERENCE
SA015PA1C1D
SA025PA1C1D
SA050PA1C1D
SA100PA1C1D
SA015PG1C1D
SA100PS1C1D
SA200PS1C1D
SA500PS1C1D
SA03KPS1C1D
REFERENCE
SA025PA1C1DE
SA050PA1C1DE
1 Vdc to 6 Vdc
(0.75)
19,0
1/8-27 NPT
SR Series
The Model SR is intended for OEMs requiring a small pressure sensor with
high pressure capability and superior corrosion resistance. Constructed of
brazen assembly of 300 series stainless steels, the SR can tolerate a wide
variety of corrosive medial without risk of leaking. The SR’s design provide
high working pressures and high overload and burst pressures at no extra
cost.
Supply voltage:
Signal conditioning:
Operating temperature range:
Compensated temperature range:
Port style:
Output type:
Termination type:
OPTIONS
MEASUREMENT TYPE
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
Gauge
A
(0.748 / 0.746)
accuracy and may cause damage. The O-ring groove on 2000 psi unit is
CAUTION: Contact with sensing surface at bottom of cavity will affect
19,0 / 18,95 18,5
wider to accommodate a backup ring behind the O-ring.
1
4,3 max.
7,6 max.
P
0
(0.30)
(0.17)
1
e r
R
0
2
P (
5
a
0
s
0
(0.75)
5 -
n
1 -
S
s
0
g
u
) I
0
0
5
e
e r
0
0
0
3 .
3 .
B
PRESSURE RANGE (PSI)
15,0 max.
All dimensions in inches (mm).
(0.625)
o
1 (
7
7
5 .
5
5
e r
2
O-RING GROOVE
0
7 .
9 (
9 (
i D
0
PRESSURE RANGE
0 psig to 15 psig
0 psig to 25 psig
0 psig to 50 psig
0 psig to 100 psig
0 psig to 200 psig
0 psig to 300 psig
0 psig to 500 psig
0 psig to 1,000 psig
0 psig to 2,000 psig
) 0
5 .
5 .
. a
) 2
) 2
O
2
2
2
-
0 -
0 -
0 -
R
n i
1
1
1
2
0
0
g
4, 22 AWG
TINNED Cu SOLID WIRES
14,0 (0.55) LONG
19,5 max.
(0.766)
*
A
2 .
2 .
2 .
-40 °C to 100 °C (-40 °F to 212 °F)
S
D
PRESSURE SENSORS
1
1
1
e
e
l a
p
5 (
5 (
5 (
h t
n i
3 .
3 .
3 .
* *
g
) 3
) 3
) 3
0 °C to 75 °C (32 °F to 167 °F)
+ Excitation
- Excitation
4 - 22 AWG tinned Cu wires
- Signal
2 .
2 .
2 .
C
D
Unamplified compensated
2
2
2
a
e
5 (
5 (
5 (
i v
p
a
c
d
h t
5 .
5 .
5 .
y t
) 8
) 8
) 8
0 mV to 100 mV
REFERENCE
SR015PGTB
SR025PGTB
SR050PGTB
SR100PGTB
SR200PGTB
SR300PGTB
SR500PGTB
SR01KPGTB
SR02KPGTB
b
+ Signal
Capsule
5.0 Vdc
133

Related parts for 2CPSC1A2A