HG2-SSUL Panasonic, HG2-SSUL Datasheet

no-image

HG2-SSUL

Manufacturer Part Number
HG2-SSUL
Description
Relay Sockets & Hardware HG2 Relay Socket (Solder Terminal)
Manufacturer
Panasonic
Datasheet
SPECIFICATIONS
Contacts
Expected life (min. operations)
Life curve for AC types
#1 This value can change due to the switching frequency, environmental conditions,
Remarks
* Specifications will vary with foreign standards certification ratings.
*
Electrical life with AC load
Note: In case of an electromagnet or exiting coil load (solenoid, etc.), the value of the motor or lamp load is applicable.
Electrical life with DC load
Note: For DC inductive load, use of an arc extinguishing circuit is recommended.
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Contact material
Nominal switching capacity
Min. switching capacity
Mechanical (at 180 cpm)
1
Measurement at same location as “Initial breakdown voltage” section
and desired reliability level, therefore it is recommended to check this with the
actual load.
(cos ϕ ] 0.4)
(cos ϕ ] 1)
Resistive
Inductive
AC load
Inductive (L/R ] 7 ms)
a
Resistive
1,000
DC load
900
800
700
600
500
400
300
200
100
#1
Voltage, V AC
0
125
250
125
250
Mechanical life : 10
36
1.417
5
56
2.205
mm
Operating frequency:
180 op./min.
10
Load current, A
inch
2 Form C, 3 Form C, 4 Form C
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.
Current, A
AC type: 10
7
20 A 250 V AC (resistive)
15
7.5
20
15
20
15
10
15
10
10
100 mA, 5 V DC
20 AMP POWER RELAY
Silver alloy
20
15 mΩ
HG2
HG3
HG4
7
, DC type: 10
(min. operations)
Voltage, V DC
Expected life
7.5×10
7.5×10
5×10
2×10
5×10
2×10
5×10
2×10
5×10
125
125
34.0
50.0
68.0
24
24
6
a
5
5
5
5
5
5
5
1.339
1.969
2.667
5
5
FEATURES
• Large capacity — 20 A 250 V AC resistive and 1.5 kW 3 phase
• High contact reliability after long use
• Usable with direct soldering,
quick-connect and plug-in terminals. (.250)
Characteristics (at 60 Hz, 20°C 68°F)
*
*
*
*
*
*
Maximum operating speed
Initial insulation resistance*
Initial
breakdown
voltage*
Operate time*
(at nominal voltage)
Release time
(without diode)*
(at nominal voltage)
Shock resistance
Vibration resistance
Conditions for operation,
transport and storage*
(Not freezing and condensing at
low temperature)
Unit weight
2
3
4
5
6
7
Motor
Detection current: 10 mA
Excluding contact bounce time
Half-wave pulse of sine wave: 11ms; detection time: 10µs
Half-wave pulse of sine wave: 6ms
Detection time: 10µs
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT
AC load
Lamp
2
Current, A
Single
phase
Three
phase
0.8
0.4
15
10
3
Between open contacts
Between contacts sets
Between contacts and coil
(approx.)
3
(approx.)
7
Voltage, V AC
HG RELAYS
220 V AC motor loads
1
125
125
250
250
2 Form C type
3 Form C &
4 Form C type
2 Form C type
3 Form C &
4 Form C type
Functional*
Destructive*
Functional*
Destructive
2 Form C type
3 Form C type
4 Form C type
Ambient
temp.
Humidity
Expected life (min. operations)
4
6
Capacity, kW
5
0.75
0.75
0.75
0.5
0.3
0.4
0.4
1.5
98 m/s
at 1 mm double amplitude
at 2 mm double amplitude
Min. 100 MΩ at 500 V DC
contact moving direction)
Approx. 130 g
Approx. 185 g
Approx. 240 g
5 × 10
5 × 10
5 × 10
5 × 10
2,000 Vrms for 1 min.
2,000 Vrms for 1 min.
2,000 Vrms for 1 min.
980 m/s
–58°F to +104°F
2
–50°C to +40°C
5 to 85% R.H.
{10 G} (except for the
5
5
5
5
Max. 30 ms
Max. 40 ms
Max. 30 ms
Max. 40 ms
10 to 55 Hz
10 to 55 Hz
20 cpm
(min. operations)
Expected life
2
{100 G}
2×10
5×10
2×10
5×10
2×10
5×10
2×10
5×10
4.59 oz
6.53 oz
8.47 oz
5
5
5
5
5
5
5
5
HG

Related parts for HG2-SSUL

HG2-SSUL Summary of contents

Page 1

... Note: For DC inductive load, use of an arc extinguishing circuit is recommended. All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. 20 AMP POWER RELAY FEATURES • Large capacity — 250 V AC resistive and 1 phase • High contact reliability after long use a HG2 34.0 1.339 • Usable with direct soldering, HG3 50.0 1.969 quick-connect and plug-in terminals ...

Page 2

... For AC types, when operating voltage is 70% of nominal coil voltage, “buzzing” will ORDERING INFORMATION Ex. HG Contact arrangement 2: 2 Form Form Form C (Note) Standard packing Carton: HG2 20 pcs. UL/CSA approved type is standard. Pick-up Drop-out voltage, voltage, allowable (max (min voltage 4 ...

Page 3

... DIMENSIONS HG2 (2 Form C) 8.4 2.5 DIA. 9 DEEP HOLE for 7 .331 3 DIA. TAPPING SCREW .276 .098 DIA. .354 DEPTH 20.5 16 .807 .630 2.5 DIA. 8 DEEP HOLE for 3 DIA. TAPPING SCREW .098 DIA. .315 DEPTH 15 .591 36 34 1.417 1.339 56 2.205 8.5 .335 AMP SERIES ...

Page 4

... HOLD DOWN Lot No. CLIP ±1 80 ±.039 3.150 ±1 58 ±0.5 35.4 ±.039 2.283 ±.020 1.394 HG2 RELAY ±0.6 34.5 ±.024 1.358 ±0.6 36 ±.024 1.417 ±0.2 ±0 ±.008 ±.008 1.024 .394 1.024 ...

Page 5

... Socket Combinations NOTES Please use the hold-down clip whenever HG relays will be used in applications where strong vibrating or shock force occurs. When used in such applications, For Cautions for Use, see Relay Technical Information All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd. ...