ES1B 115-165C Omron, ES1B 115-165C Datasheet - Page 5

no-image

ES1B 115-165C

Manufacturer Part Number
ES1B 115-165C
Description
Sensor Hardware & Accessories IR Thermosensor 115-165C
Manufacturer
Omron
Datasheets

Specifications of ES1B 115-165C

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Example for the E5CN
In this example, the ES1B is used between 140 and 260°C. Here, the
set point lower limit, YL, would be 0°C and the set point upper limit,
YH, would be 260°C in formulas 1 and 2. The temperatures of the
sensing object are checked next.
The offset values can be calculated as shown below when the Con-
troller display Y1 is 40°C for a room temperature X1 of 25°C and
when the Controller display Y2 is 105°C for a set point temperature
X2 of 110°C
Upper-limit Temperature Input Setting
Lower-limit Temperature Input Setting
i n s l
i n s h
temperature input
C
Lower-limit
= −27.3 (°C)
= 52.7 (°C)
=
=
insl
105−40
260−40
105−40
0−40
-27
×{(110−105)−(25−40)}+(25−40)
×{(110−105)−(25−40)}+(25−40)
temperature input
C
Upper-limit
insh
53
Infrared Thermosensor
ES1B
5