PLRXPL-SC-S43-22-N JDS UNIPHASE, PLRXPL-SC-S43-22-N Datasheet

no-image

PLRXPL-SC-S43-22-N

Manufacturer Part Number
PLRXPL-SC-S43-22-N
Description
Manufacturer
JDS UNIPHASE
Datasheet

Specifications of PLRXPL-SC-S43-22-N

Optical Fiber Type
TX/RX
Data Transfer Rate
10520Mbps
Optical Rise Time
0.028ns
Optical Fall Time
0.028ns
Operating Temperature Classification
Commercial
Peak Wavelength
850nm
Package Type
SFP
Operating Supply Voltage (min)
3.14V
Operating Supply Voltage (typ)
3.3V
Operating Supply Voltage (max)
3.47V
Operating Temp Range
0C to 70C
Mounting
Panel
Pin Count
20
Lead Free Status / Rohs Status
Compliant
10 G SFP+ 850 nm Limiting Transceiver,
10 Gigabit Ethernet Compliant
PLRXPL-Sx-S43-22-N Series
Applications
• High-speed local area networks
• Computer cluster crossconnect systems
• Custom high-bandwidth data pipes
Compliance
• SFF 8431 Revision 3.2
• SFF 8432 Revision 5.0
• SFF 8472 Revision 10.3
• IEEE 802.3 Clause 52 10GBASE-SR
• 10 G Fibre Channel
• CDRH and IEC60825-1 Class 1 Laser
• FCC Class B
• ESD Class 2 per MIL-STD 883
• UL 94, V0
• Reliability tested per Telcordia GR-468
and 10GBASE-SW
Eye Safety
Method 3015
- Switches and routers
- Network interface cards
NORTH AMERICA: 800 498-JDSU (5378)
Key Features
The lead-free and RoHS-compliant small form factor pluggable (SFP+) transceiver
from JDSU improves the performance for 10 Gigabit Ethernet (10 G) applications,
and is ideal for high-speed, local area network applications. This transceiver
features a highly reliable, 850 nm, oxide, vertical-cavity surface-emitting laser
(VCSEL) coupled to an LC optical connector. The transceiver is fully compliant to
10GBASE-SR, 10GBASE-SW and 10 G Fibre Channel specifications, with internal
AC coupling on both transmit and receive data signals. The all-metal housing
design provides low EMI emissions in demanding 10 G applications and conforms
to IPF specifications. An enhanced digital diagnostic feature set allows for real-
time monitoring of transceiver performance and system stability, and the serial ID
allows for customer and vendor system information to be stored in the transceiver.
Transmit disable, loss-of-signal, and transmitter fault functions are also provided.
The small size of the transceiver allows for high-density board designs that, in
turn, enable greater total bandwidth.
COMMUNICATIONS MODULES & SUBSYSTEMS
WORLDWIDE: +800 5378-JDSU
• Compliant to industrywide, 10 G link specifications
• Uses a highly reliable, 850 nm oxide VCSEL
• Lead-free and RoHS 6/6-compliant, with allowed exemptions
• Commercial case operating temperature 0 – 70°C;
• Single 3.3 V power supply
• Low power consumption (typically 450 mW)
• Bit error rate < 1 x 10
• Hot pluggable
extended temperature operating up to 85°
-12
WEBSITE: www.jdsu.com

Related parts for PLRXPL-SC-S43-22-N

PLRXPL-SC-S43-22-N Summary of contents

Page 1

... G SFP+ 850 nm Limiting Transceiver, 10 Gigabit Ethernet Compliant PLRXPL-Sx-S43-22-N Series Applications • High-speed local area networks - Switches and routers - Network interface cards • Computer cluster crossconnect systems • Custom high-bandwidth data pipes Compliance • SFF 8431 Revision 3.2 • SFF 8432 Revision 5.0 • ...

Page 2

... G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPLIANT Section 1 Functional Description The PLRXPL-Sx-S43-22 SFP+ 850 nm optical transceiver is designed to transmit and receive 64B/66B scrambled 10 G serial optical data over 50/125 µm or 62.5/125 µm multimode optical fiber. Transmitter The transmitter converts 64B/66B scrambled serial PECL or CML electrical data into serial optical data compliant with the 10GBASE-SR, 10GBASE- Fibre channel standard ...

Page 3

VCC_TX TX_DIS TOSA TX_GND SCL Management Processor SDA EEPROM VCC_RX ROSA RX_GND Figure SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPLIANT 10 kΩ TD+ Laser Driver 100 Ω TX_FAULT Ω 50 VCC_RX RD ...

Page 4

Vcc 10 kΩ Receiver (Tx Fault) CMOS, TTL, or Open Collector Driver Vcc (Tx Disable) Rp*** Open Collector Bidirectional SDA Vcc *** Rq Open Collector Bidirectional Vcc SCL Vcc 10 kΩ R5 ∗∗ Mod_ABS CMOS or TTL Driver (RS0 ...

Page 5

Power Supply Filter Component Values Component L1, L2 Rx, Ry C1, C5 C2, C3 Notes: Option A is recommended for use in applications with space constraints. Power supply noise must be less than 100 mV Option B ...

Page 6

... Section 3.10 Module Outline • Section 3.11 Transceiver Belly-to-belly Mounting 3.1 Pin Function Definitions RS1 EE 12 RD- R _LOS X 13 RD+ RS0 _ABS SCL SDA TX_D ISABLE 18 TD+ TX_F AULT 19 TD Figure 3 Host PCB SFP+ Pad assignment top view OWARD 4 B EZEL PLRXPL-Vx-SH4-21xN JDSU | ...

Page 7

SFP+ Optical Transceiver Pin Descriptions Pin Number Symbol Name Receiver 8 LOS Loss of Signal Out (OC) 10, 11 Receiver Signal Ground eeR 12 RD- Receiver Negative DATA Out (PECL) 13 RD+ Receiver Positive DATA Out (PECL) ...

Page 8

... Damage may occur if the device is subjected to conditions beyond the limits stated here. 3.3 Operating Conditions Part Number PLRXPL-SC-S43-xx-N PLRXPL-SE-S43-xx-N Note: Performance is not guaranteed and reliability is not implied for operation at any condition outside these limits SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPLIANT ...

Page 9

Electrical Characteristics Parameter Symbol Supply voltage V cc Power consumption P diss Data rate Transmitter Supply current I ccT DV Common mode voltage tolerance Data dependent input jitter DDJ Data input uncorrelated jitter Uj Data input total jitter ...

Page 10

Optical Characteristics Parameter Symbol Transmitter l Wavelength p RMS spectral width Average optical power P AVG Optical modulation amplitude OMA Transmitter dispersion penalty TDP Relative intensity noise RIN Receiver l Wavelength Maximum input power P max Sensitivity (OMA) ...

Page 11

Link Length Data Rate Standard Fiber Type 10.3 GBd 62.5/125 µm MMF 50/125 µm MMF 50/125 µm MMF 50/125 µm MMF 50/125 µm MMF 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPLIANT Modal Bandwidth at ...

Page 12

... The PLRXPL-Sx-S43-22-N optical transceiver is lead-free and RoHS-compliant per Directive 2002/95/EC of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in elec- trical and electronic equipment ...

Page 13

PCB Layout 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPLIANT Figure 4 Board layout Figure 5 Detail layout ALL DIMENSIONS ARE IN MILLIMETERS ...

Page 14

Front Panel Opening 3.10 Module Outline 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPLIANT Figure 6 ALL DIMENSIONS ARE IN MILLIMETERS Figure 7 ...

Page 15

Transceiver Belly-to-belly Mounting 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPLIANT Figure 8 ...

Page 16

... Eye safety 4.1 Digital Diagnostic Monitoring and Serial ID Operation The PLRXPL-Sx-S43-22-N optical transceiver is equipped with a two-wire serial EEPROM that is used to store specific information about the type and identi- fication of the transceiver as well as real-time digitized information relating to the transceiver’s performance. See the Small Form Factor Committee document number SFF-8472 Revision 10 ...

Page 17

Data Field Descriptions Address( 1010000X)(A0h) 0 Serial ID Information; Defined by SFP MSA 95 JDSU-Specific Information 127 Reserved for SFP MSA 255 10 G SFP+ 850 NM LIMITING TRANSCEIVER, 10 GIGABIT ETHERNET COMPLIANT Reading the data The information is ...

Page 18

... OM3 50/125 µm multimode fiber JDSU Vendor Name (ASCII) 00 Reserved 00019C IEEE Company ID (ASCII) PLRXPLSxS43xxN Part Number (ASCII part number variable Revision of part number (ASCII) 0352 Wavelength of laser in nm; 850 Unallocated CC_BASE Check Code; Lower 8 bits of sum from byte 0 through 62 ...

Page 19

Diagnostics Data Map Memory Address Value 00-01 Temp High Alarm 02-03 Temp Low Alarm 04-05 Temp High Warning 06-07 Temp Low Warning 08-09 Voltage High Alarm 10-11 Voltage Low Alarm 12-13 Voltage High Warning 14-15 Voltage Low Warning 16-17 ...

Page 20

Diagnostics Data Map Memory Address Value 101 TX Bias LSB (Note 1) 102 TX Power MSB (Note 1) 103 TX Power LSB (Note 1) 104 RX Power MSB 105 RX Power LSB 106 Reserved MSB 107 Reserved LSB 108 ...

Page 21

... Package and Handling Instructions This product is not compatible with any aqueous wash process. Process plug The PLRXPL-Sx-S43-22-N optical transceiver is supplied with a process plug. This plug protects the transceiver’s optics during standard manufacturing processes by preventing contamination from air borne particles. ...

Page 22

... Ordering Information For more information on this or other products and their availability, please contact your local JDSU account manager or JDSU directly at 1-800-498-JDSU (5378) in North America and +800-5378-JDSU worldwide, or via e-mail at customer.service@jdsu.com. Sample: PLRXPL-SC-S43-22-N Part Number Product Description PLRXPL-SC-S43-22 SFP+ SR compliant, limiting electrical interface, 0 – 70˚C, ± 5% Vcc, no rate select, generic PLRXPL-SE-S43-22 SFP+ SR compliant, limiting electrical interface, -5 – ...

Related keywords