Specifications of 1-794954-6

No. Of Positions
16
Pitch Spacing
4.2mm
Connector Type
Plug & Socket
Connector Mounting
Cable
No. Of Contacts
16
Rohs Compliant
Yes
Product Type
Connector
Termination Method To Wire/cable
Crimp
Sealed
No
Ul File Number
E28476
Csa File Number
208567
Mating Retention Type
Latching
Contact Current Rating, Max (a)
9
Operating Voltage Reference
AC
Operating Voltage (vac)
600
Profile Height (y-axis) (mm [in])
9.80 [0.386]
Number Of Positions
16
Number Of Rows
2
Centerline (mm [in])
4.20 [0.165]
Mating Retention
With
Selectively Loaded
No
Length (x-axis) (mm [in])
35.20 [1.3858]
Width (z-axis) (mm [in])
20.00 [0.787]
Contact Type
Socket
Contact Design
Dual Beam
Connector Style
Receptacle
Mating Alignment
With
Mating Alignment Type
Keyed
Housing Color
Natural
Ul Flammability Rating
UL 94V-2
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Agency/standard
UL, CSA
Ul Rating
Recognized
Circuit Identification Feature
With
Operating Temperature (°c [°f])
-40 – +105 [-40 – +221]
Applies To
Wire/Cable
Application Use
Wire-to-Board, Wire-to-Board / Wire-to-Wire, Wire-to-Wire
Contact Transmits (typical Application)
Signal (Data)
Pick And Place Cover
Without
Packaging Method
Bag
For Use With
VAL-U-LOK Series Connector System

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
1-794954-6
Manufacturer:
TE
Quantity:
20 000
Part Number:
1-794954-6
Manufacturer:
TE Connectivity AMP Connectors
Quantity:
1 355
Part Number:
1-794954-6
Manufacturer:
TE
Quantity:
35 000
3.3.
3.4.
3.5.
Initial exam ination of product.
Final exam ination of product.
Low Level Contact Resistance
(LLCR).
Insulation resistance.
W ithstanding voltage.
Tem perature rise vs current.
Sinusoidal vibration.
Mechanical shock.
Rev B
Ratings
!
!
!
Perform ance and Test Description
Product is designed to m eet the electrical, m echanical and environm ental perform ance requirem ents
specified in Figure 1. Unless otherwise specified, all tests shall be perform ed at am bient environm ental
conditions.
Test Requirem ents and Procedures Sum m ary
Test Description
Voltage: 600 volts AC
Current: 9 am peres m axim um , 2 position application
Tem perature: -40 to 105°C
Meets visual requirem ents.
Meets requirem ents of product
drawing and Application
Specification 114-13172.
10 m illiohm s m axim um .
1000 m egohm s m inim um .
One m inute hold with no breakdown
or flashover.
30°C m axim um tem perature rise at
specified current.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
No discontinuities of 1 m icrosecond
or longer duration.
See Note.
Figure 1 (continued)
MECHANICAL
ELECTRICAL
Requirem ent
EIA-364-18.
EIA-364-21.
EIA-364-18.
Visual and dim ensional (C of C)
inspection per product drawing.
Visual inspection.
EIA-364-23.
Subject specim ens to 100
m illiam peres m axim um and 20
m illivolts m axim um open circuit
voltage.
500 volts DC, 2 m inute hold.
Test between adjacent contacts.
EIA-364-20, Condition I.
1500 volts AC at sea level.
Test between adjacent contacts.
EIA-364-70, Method 1.
Stabilize at a single current level
until 3 readings at 5 m inute intervals
are within 1°C.
EIA-364-28, Test Condition I.
Subject m ated specim ens to 10 to
55 to 10 Hz traversed in 1 m inute
with 1.5 m m m axim um total
excursion. Two hours in each of 3
m utually perpendicular planes.
EIA-364-27, Condition A.
Subject m ated specim ens to 50 G's
half-sine shock pulses of 11
m illiseconds duration. Three shocks
in each direction applied along 3
m utually perpendicular planes, 18
total shocks.
Procedure
108-2112
2 of 5

Related parts for 1-794954-6